T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester
T6-1000 Non-Contact Voltage and Current Tester

T6-1000 Non-Contact Voltage and Current Tester

Main characteristics

  • FieldSense technology improves troubleshooting by simultaneously measuring AC voltage and current* directly through the jaws.
  • U-shaped jaws for tight measurement spaces
  • FieldSense technology eliminates the need for a stylus to touch live contacts, further isolating the safety risks of high-voltage work+.
  • 0.1 to 200 A AC Current Test
  • true rms
  • Resistance: 1 Ω to 100 kΩ
  • Frequency test range: 45 Hz to 66 Hz
  • For AWG 4/0 (120 mm2) size class conductors with 17.8 mm jaw opening
  • Optional Fluke TPAK Magnetometer Hook for Easy Handling
  • Two-year standard warranty; can be extended to 4 years if product is registered within 45 days of purchase*

+ Only: single phase wire (not applicable to double or multi-stranded wires containing zero/ground etc.), operating frequency 45~66Hz, AC voltage above 16V.
* Warranty can be extended to four years if the product is registered online within 45 days of purchase. See also http://a.fluke.com/registration for details. Additional two-year warranty service may be interrupted without notice

SKU:T6-1000 Category. Brand.

Inquire about this product

Product Overview: T6-1000 Non-Contact Voltage and Current Tester

From now on, say goodbye to the pen, AC current/voltage measurement, a "clamp" can be two.

The Fluke T6, with its innovative FieldSense technology, can simultaneously measure AC voltage and current* through the jaws, without the need for a stylus to touch the contacts! (T6-600 requires key switching to display current/voltage readings)
Particularly suitable for residential, CBD, supermarkets and other property staff daily quick inspection. Daily inspection without having to carry a clamp meter, multimeter and other pieces of instrumentation, a T6 easily complete the routine work.
The small 17.8mm open jaws are designed to handle tight measuring spaces or dense wiring.
FieldSense technology brings non-contact jaw measurement voltage way, no need to strip the wire or open the metal electrocution protection mechanism, can be carried out through the jaws without (table) "pen" fast voltage measurement of the new experience, and further isolate the potential risk of electrocution operations. Suitable for maximum 120 square cables detection, is 200 kilowatts (200KW) and the following motors, low-voltage motors, low-voltage distribution cabinets, the ideal fast inspection tool.

*  Only: single phase wire (not applicable to double or multi-stranded wires containing zero/ground etc.), operating frequency 45~66HZ, AC voltage above 16V.
+ Voltage measurements require grounding through the black pen for more accurate readings [± (3 % + 3 counts)]. Actual readings may vary depending on actual grounding conditions.

Product Specifications: T6-1000 Non-Contact Voltage and Current Tester

Measurement specifications
functionality Test Leads Required range (of scales or measuring equipment) resolution (of a photo) accurate[1]
FieldSense
AC Voltage True RMS
not have 1000 V 1 V ± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]
FieldSense
AC Current True RMS
not have 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz - 66 Hz
FieldSense
Frequency (Hz)
not have 45 Hz - 66 Hz 1 Hz ± (1% + 2 counts)[3]
AC Voltage True RMS be 1000 V 1 V ± (1.5% + 2 counts) 45 Hz - 66 Hz
dc voltage be 1000 V 1 V ± (1% + 2 counts)
resistive be 2000 Ω 1 Ω ± (1% + 2 counts)
be 20.00 kΩ 0.01 kΩ
be 100.0 kΩ 0.1 kΩ
security level 1000 V CAT III
600 V CAT IV
accurate [1]: ± ([% of reading] + [lowest RMS digit]). Accuracy applies for one year after calibration at operating temperatures from 18 °C to 28 °C (64 °F to 82 °F) and relative humidity to 90 %. AC Measurements: AC coupled, RMS response.
accurate [2]: Add 3 % without an external ground connection. External grounding requires the user to wear insulated gloves, stand on an insulated ladder, or otherwise be insulated from the ground.
accurate [3]: FieldSense can be specified from 16 V to full scale.
General technical indicators
calibrations 1 year calibration cycle
sizes 61.1 x 259.3 x 43.8 mm
Jaw Opening 17.8 mm
weights 0.35 kg (0.78 lb)
temp
Work:
Storage:
-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
humidity level
Work:
Storage:
2,000 meters (6,562 feet)
10,000 meters (32,808 feet)
relative humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% through 75%, 30 °C through 40 °C (86 °F through 104 °F)
0% through 45%, 40 °C through 50 °C (104 °F through 122 °F)
Battery type and life time Two AA type alkaline batteries (IEC LR6); 360 hours standard battery life; 200 hours battery life (with FieldSense)
temperature coefficient 0.1 x (specified accuracy) / °C (28 °C)
( 82.4 °F)
security level IEC/EN 61010-1: Contamination class 2
electromagnetic environment IEC/EN 61326-1: Portability

Model: T6-1000 Non-Contact Voltage and Current Tester

T6-1000 Non-Contact Voltage Clamp Meter
  • Quick Reference Guide
  • warranty card
  • grip
  • writing brush

T6-1000 technical parameters [please login to download and view].

 

Expand More
T6-1000 Non-Contact Voltage and Current TesterT6-1000 Non-Contact Voltage and Current Tester

Click to enquire

Product consultation and purchase:18218718851

I already understand