Main characteristics

  • Unique 40A small range, high accuracy current test - 0.01A high resolution, 1.6% high accuracy measurement
  • Slim and lightweight pliers are ideal for easy use in confined spaces.
  • Large backlit display for easy reading in dark environments
  • Start-up current function (319), which measures the start-up current of devices such as motors and lights
  • Current Frequency Measurement
  • Digital Clamp Meter Accuracy Above 0.01A and 0.1V
  • 1000A AC/DC current measurement (319)
  • 600V AC/DC voltage measurement
  • 4000Ω resistance measurement
  • Digital Clamp Meter Sensitive On-Off Measurement
  • Automatic shutdown function to maximize battery life so that the instrument can work when required
  • Display retention function to keep measurement results on the screen
  • One year warranty

SKU:Fluke 317/319 Category. Brand.

Inquire about this product

Product Overview: Fluke 317/319 True RMS AC/DC Digital Clamp Meter/Ammeter

The Fluke 317/319 True RMS AC/DC Digital Clamp Meters have an ergonomic design with a streamlined shape that is easier to hold in your hand. These two slim, rugged digital clamp-on ammeters are ideal for easy 1000 A current measurements (319) and for use in confined spaces. The 317 and 319 have an accurate 40 A small range. In addition to a range of test functions, the FLUKE 319 digital clamp-on ammeter also features start-up current and frequency functions for easy measurements on equipment such as motors and lighting.

NPI-301-Banner

Product Specifications: Fluke 317/319 True RMS AC/DC Digital Clamp Meter/Ammeter

technical specification
digital frequency display (DFD)
 6000 character resolution
Battery low indication
 Battery low indication
power supply
 3 x AAA IEC LR03 batteries
Digital Clamp Meter Jaw Opening
 1.45 in (37 mm)
Clamp opening
 1.45 in (37 mm)
Digital Clamp Meter Dimensions (LxWxH)
 9.21 in x 2.95 in x 1.37 in
 234.0 mm x 75.0 mm x 34.8 mm
Digital Clamp Meter Weight
 384g (including battery)
Auto range
 Ohms
surety
 CE
 EN/IEC 61010-1 and IEC 61010-2-032
 Installation category III, 600 V operating environment

 

317 Technical indicators
alternating current (electricity)
range (of scales or measuring equipment)  40.00 A, 600.0 A
resolution (of a photo)  0.01 A, 0.1 A
accuracy  1.6% ± 6 words (50-60 Hz) {40 A}
 2.5% ± 8 words (60-500 Hz) {40 A}
 1.5% ± 5 words (50-60 Hz) {600 A}
 2.5% ± 5 words (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response  true rms
direct current
range (of scales or measuring equipment)  40.00 A, 600.0 A
resolution (of a photo)  0.01 A, 0.1 A
accuracy  1.6% ± 6 words (40 A)
 1.5% ± 5 words (600 A)
alternating current
range (of scales or measuring equipment)  600.0 V
resolution (of a photo)  0.1 V
accuracy  1.5% ± 5 words (20-500Hz)
AC response  true rms
dc voltage
range (of scales or measuring equipment)  600.0 V
resolution (of a photo)  0.1 V
accuracy  1% ± 4 words
resolution (of a photo)
range (of scales or measuring equipment)  400.0 Ω, 4000 Ω
resolution (of a photo)  0.1 Ω, 1 Ω
accuracy  1% ± 5 words
Low Pass Filter Parameters Built-in, 900Hz
On-off measurement
 ≤ 30 Ω
starting current
response time  not matching up
Frequency measurement
range (of scales or measuring equipment)  not matching up
accuracy  not matching up
trigger level  not matching up

 

319 Technical indicators
alternating current (electricity)
range (of scales or measuring equipment)  40.00 A, 600.0 A, 1000 A
resolution (of a photo)  0.01 A, 0.1 A, 1 A
accuracy  1.6% ± 6 words (50-60 Hz) {40 A}
 2.5% ± 8 words (60-500 Hz) {40 A}
 1.5% ± 5 words (50-60 Hz) {600/1000 A}
 2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor and 2% to specification CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response  true rms
direct current
range (of scales or measuring equipment)  40.00 A, 600.0 A, 1000 A
resolution (of a photo)  0.01 A, 0.1 A, 1 A
accuracy  1.6% ± 6 words (40 A)
 1.5% ± 5 words (600/1000 A)
alternating current
range (of scales or measuring equipment)  600.0 V
resolution (of a photo)  0.1 V
accuracy  1.5% ± 5 words (20-500Hz)
AC response  true rms
dc voltage
range (of scales or measuring equipment)  600.0 V
resolution (of a photo)  0.1 V
accuracy  1% ± 4 words
resolution (of a photo)
range (of scales or measuring equipment)  400.0 Ω
 4000 Ω
resolution (of a photo)  0.1 Ω
 1 Ω
accuracy  1% ± 5 words
Low Pass Filter Parameters Built-in, 900Hz
On-off measurement
 ≤ 30 Ω
starting current
response time  100 milliseconds
Frequency measurement
range (of scales or measuring equipment)  5.0 - 500.0 Hz
accuracy  0.5% ± 5 words
trigger level  10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A

All accuracy indicators refer to 73 °F ± 41 °F (23 °C ± 5 °C).

Below 64 °F and above 82 °F (18 °C and above 28 °C)

 

Environmental parameters.
Digital Clamp Meter Operating Temperature
 14°F to 122°F (-10 °C to 50 °C)
Storage temperature
 -40 °F to 140 °F (-40 °C to 60 °C)
Operating humidity
 No fog (< 50 °F) (< 10 °C)
 90 % RH (50 °F to 86 °F) (10 °C to 30 °C)
 75 % RH (86 °F to 104 °F) (30 °C to 40 °C)
 45 % RH (104 °F to 122 °F) (40 °C to 50 °C)
 No fog.
Working altitude
 Altitude 2000 meters
Storage altitude
 12,000 meters above sea level
IP metrics
 IP40
Digital Clamp Meter Vibration Requirements
 Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop Test Requirements
 kilometer
EMI, RFI, EMC
 Not specified for use in EMC environments ≥ 0.1 V/m
temperature coefficient
 0.1x (specified accuracy)/ °C
 ( 82° F)
 ( 28 °C)

Model: Fluke 317/319 True RMS AC/DC Digital Clamp Meter/Ammeter

Fluke 317/319
Fluke 317/319 True RMS AC/DC Digital Clamp Meter/Ammeter

 

 

Fluke 319HS1

Model: Fluke 319HS1 Clamp Meter

Included:

  • One Fluke 319 clamp meter
  • TL75 Meter Pen
  • 3 AAA batteries
  • IPHS1 Phillips head insulated screwdriver

F317-319 technical parameters [please login to download and view].

319 317 Instruction manual SC [please login to download and view]

Expand More
Fluke 317/319 True RMS AC/DC Digital Clamp Meter/AmmeterFluke 317/319 True RMS AC/DC Digital Clamp Meter/Ammeter

Click to enquire

Product consultation and purchase:18218718851

I already understand