Main characteristics

  • Tests L-N, N-PE input on/off
  • Test Smooth DC Sensitive RCD (Type B)
  • Testing grounding resistance, voltage and frequency
  • Various test voltages are available: 50 V, 100 V, 250 V, 500 V, 1000 V.
  • 6 mA RDC-DD Test for Electric Vehicle Charging Posts

SKU:Fluke 1663 Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 1663 Multi-Function Installation Tester

Fluke 1663 Multi-Function Installation Tester for Hardworking Professionals

The Fluke 1663 Installation Tester offers the full range of features and advanced measurement capabilities required by professional installers. It is compact and lightweight (less than 1.3 kg), with a padded backpack and belt for easy portability. The tester is intuitive and easy for skilled workers of all levels to master, and can be put to use immediately to carry out tests quickly and efficiently in accordance with all local regulations. Other features include an on/off switching auto-start function for RCD and loop testing and a self-test function that saves you time and gives you confidence in your results.

Testing of electric vehicle charging post RCD A-EV or RDC-DD type DC protection devices

The tester tests electric vehicle charging post DC protection devices using the RCD Type B (Smooth DC Current) VAR mode, which is based on the IEC 62955 standard, and generates test currents (6/60/200 mA and <2 to 6 mA ramps) for either RCD Type A-EV or RDC-DD devices. This makes it quick and easy to test the 6 mA DC monitor attached to the charging post and can be used in conjunction with the Fluke FEV100 or FEV300.

software compatibility

Compatible with Fluke's TruTest™ software, the Fluke 1663 lets you say goodbye to the traditional hassles of electrical system data management and reporting. Whether you're testing fixed-wire devices or electrical appliances in the office, verifying repairs in the shop, or performing annual inspections, proper data management is critical to generating easy-to-understand reports for your customers, and TruTest™ software makes it easy to quickly and easily import measurements directly from your test instrument, manage files transferred from your instrument, or manually enter data as needed.

Other useful features:

  • Check wiring polarity to detect a disconnected zero wire
  • Measurement of insulation resistance as well as loop and line resistance
  • Z-max memory with loop test for easy evaluation of highest loop test values
  • Equipped with a unique zeroing adapter for fast, reliable, and accurate compensation of test pens and power cords
  • Measurement of motor windings using on-off test
  • Calculation of the Expected Earth Fault Current (PEFC/IK) and Expected Short Circuit Current (PSC/IK)
  • Measurement of RCD switching time and trip level (ramp test)
  • Simultaneous measurement of trip time and current for RCD A and AC types in one test
  • Measuring RCD Variable Current
  • Provides automated RCD test sequences
  • Includes phase sequence indicator
  • Safety class CAT III 500 V, CAT IV 300 V

Product Specification: Fluke 1663 Multi-Function Installation Tester

Specifications: Fluke 1663 and 1664 FC Multi-Function Installation Testers

AC Voltage Measurement
range (of scales or measuring equipment) 500 V
resolution (of a photo) 0.1 V
Accuracy (45 Hz - 66 Hz) 0.8% + 3
Input Impedance 360 kΩ
overload protection 660 V rms
Turn-On-Line Test (RLO)
Range (automatic) 20 Ω / 200 Ω / 2000 Ω
resolution (of a photo) 0.01 Ω / 0.1 Ω / 1 Ω
open circuit voltage >4 V
Insulation Resistance Measurement (RISO)
test voltage 50-100-250-500-1000 V
Test voltage accuracy (at rated test current) +10%/-0%
test voltage 50 V
100 V
250 V
500 V
1000 V
Insulation resistance range 20 MΩ / 50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ
resolution (of a photo) 0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
Test Current 1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ
Loop and Line Impedance (ZI)
range (of scales or measuring equipment) 10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω
resolution (of a photo) 0.001 Ω/ 0.01 Ω/ 0.1 Ω/1 Ω
Expected Ground Fault Current, PSC Test
range (of scales or measuring equipment) 1000 A / 10 kA (50 kA)
resolution (of a photo) 1 A / 0.1 kA
count The Expected Ground Fault Current (PEFC) or Expected Short Circuit Current (PSC) is determined by dividing the measured supply voltage by the measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD Test, RCD Type Measured
RCD Type AC¹
G², S³
1663 Model A4, AC¹, G², S³
1664 FC Models A, AC, B5, S
marginal notes ¹Corresponds to AC
² General purpose, no delay
³ time delay
⁴ Corresponding pulse signal
⁵ corresponds to a smooth DC signal
Trip Speed Test (ΔT)
Current setting¹ 10-30-100-300-500-1000 mA - VAR
10-30-100 mA
factor x ½, x 1
x 5
VAR Mode Type B - 6, 60, 200 mA
Measurement range RCD G-Type 310 ms
50 ms
RCD S-Type 510 ms
160 ms
EV / RDC-DD 6 mA - 10s
60 mA - 0.3s
200 mA - 0.1s
marginal notes ¹1000 mA AC models only
700 mA max, Type A in VAR mode
The VAR mode of the RCD Type B (Smooth DC Current) generates test currents (6/60/200 mA and <2 to 6 mA ramps) for use with the RCD Type A-EV or RDC-DD according to IEC 62955.
RCD/FI Trip Current Measurement/Ramp Test (IΔN)
Current range 30% to 110%¹ for RCD rated current
<2 mA to 6 mA Smooth DC³
pacemaker 10%² of IΔN
Linear increase within 30 s
Holding time RCD G-Type 300 ms/step
RCD S-Type 500 ms/step
Measurement accuracy ±5%
Specified trip current range (EN 61008-1) AC Models 50% through 100%
Type A (>10 mA) for 35% to 140%
Type A (≤10 mA) for 35% to 200%
Model B is 50% through 200%.
marginal notes Type ¹A (IΔN > 10 mA) for 30% to 150%
Type A (IΔN = 10 mA) for 30% through 210%
Model B is 20% through 210%.
²B Type 5%
³ For RCD Type A-EV/RDC-DD according to IEC 62955
Ground Resistance Test (RE)
range (of scales or measuring equipment) 200 Ω / 2000 Ω
resolution (of a photo) 0.1 Ω / 1Ω
frequency 128 Hz
output voltage 25 V
phase sequence indication
icon (computing)   Phase Sequence Indicator Icon    Phase sequence indicator active.
General technical indicators
Dimensions (L x W x H) 10 x 25 x 12.5 cm
Weight (with battery) 1.3 Kg
Battery type and quantity AA Type, 6 Sections
tightness IP-40
safety Conforms to EN/IEC 61010-1 and EN/IEC 61010-2-034 standards.
overvoltage CAT III / 500V; CAT IV 300V
performances EN61557-1 to EN61557-7 and EN61557-10

Model: Fluke 1663 Multi-Function Installation Tester

FLK-1663

Fluke 1663 Multi-Function Installation Tester

Kit Includes:

  • 6 AA (IEC LR6) batteries
  • C1600 Hard Carrying Case
  • Zeroing Adapter
  • Heavy Duty Power Cord
  • STD Standard Test Pen Kit
  • Padded back and waist straps
  • Quick Reference Guide
  • TP165X Remote Control Probe and Meter Pen
Expand More
Fluke 1663 Multi-Function Installation TesterFluke 1663 Multi-Function Installation Tester
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand