Product Overview: Fluke 6500-2 Electrical Safety Tester
Perform more tests per day
The Fluke 6500-2 Appliance Safety Tester is a lightweight, compact, one-button solution with automated testing features that have been redesigned to help you get more portable appliance testing done every day.The 6500-2 is designed to work faster without compromising test results.
One-Click Solutions...
A preset test program can be initiated at the push of a button. Not only does this simplify testing, but it also allows for a faster, more efficient way of working. 6500-2 is a fully automated unit with user-definable test programs and a QWERTY keypad that facilitates quick data entry.
light weight...
Weighing approximately 3 kg, the 6500-2 is lightweight and portable, making it easy to work in the field. The rugged carrying case (standard) not only provides transportation protection, but also additional storage space for accessories and other tools.
small volume...
This portable appliance tester is extremely compact and has the usual Fluke durability for field work.The Fluke Appliance Safety Tester is a complete all-in-one solution with all the features needed to test portable appliances.
Product Specification: Fluke 6500-2 Electrical Safety Tester
| Technical indicators | ||
| Test specifications | The accuracy metric for the display range is defined as ±(% reading + word count) for 23 °C ±5 °C and ≤75% RH. | |
| The accuracy index decreases per °C ( 0.1 x accuracy index) from 0 °C to 18 °C and from 28 °C to 40 °C. | ||
| The ranges comply with the service operating error requirements specified in EN 61557-1: 1997, EN 61557-2: 1997, EN 61557-4: 1997, EN 61557-6: 1997, DIN VDE0404-2. | ||
| power-on test | The test indicates reverse L-N, missing PE, and measures supply voltage and frequency. | |
| Display range | 90 V to 264 V | |
| Accuracy @ 50 Hz | ± (2% + 3 words) | |
| resolution (of a photo) | 0.1 V | |
| Input Impedance | > 1 MΩ // 2.2 nF | |
| Maximum input supply voltage: | 264 V | |
| Ground connection test (Rpe) | Display range | 0 to 19.99 Ω |
| Accuracy (after ground test zeroing) | ± (5% + 4 words) | |
| resolution (of a photo) | 0.01 Ω | |
| Test Current | 200 mA AC -0% +40%, 1.99 Ω 10 A AC ±20%, 25 mΩ @ 230 V |
|
| open circuit voltage | > 4 V AC, < 24 V AC | |
| Ground test zeroing | Subtract up to 1.99 Ω | |
| Insulation test (Riso) | Display range | 0 to 299 MΩ |
| accuracy | ±(5% + 2 words), 0.1 to 300 MΩ | |
| resolution (of a photo) | 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) |
|
| test voltage | 500 V DC -0% + 25% @ 500 kΩ load or 250 V dc -0% +25% @ 250 kΩ load | |
| Test Current | > 1 mA @ 500 kΩ load, < 15 mA @ 0 Ω | |
| Automatic discharge time | < 0.5 s, 1 μF | |
| Maximum capacitive load | Operates up to 1 μF | |
| Contact Current Test | Display range | 0 to 1.99 mA, AC |
| accuracy | ± (4% + 2 words) | |
| resolution (of a photo) | 0.01 mA | |
| Internal resistance (via probe) | 2 kΩ | |
| Measurement Methods | Probe* | |
| Alternative Leakage Current Test | Display range | 0 to 19.99 mA, AC |
| accuracy | ± (2.5% + 3 words) | |
| resolution (of a photo) | 0.01 mA | |
| test voltage | 100 V AC ±20% | |
| Load/Leakage Test: Load Current | Display range | 0 A to 13 A |
| accuracy | ± (4% + 2 words) | |
| resolution (of a photo) | 0.1 A* | |
| Load/Leakage Current Test: Load Power | Display range 230 V power supply | 0.0 VA to 3.2 kVA |
| accuracy | ± (5% + 3 words) | |
| resolution (of a photo) | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
| Load/Leakage Current Test: Leakage Current | Display range | 0 to 19.99 mA |
| accuracy | ± (4% + 4 words) | |
| resolution (of a photo) | 0.01 mA* | |
| PELV test | Accuracy @ 50 Hz | ± (2% + 3 words) |
| overload protection | 300 V rms | |
| alarm threshold | 25 V rms | |
| RCD test: disconnecting current | operating error | ±10% |
| nominal value | 30 mA | |
| accuracy | ±5% | |
| RCD test: decoupling time | standardized requirements | 61557 Chapter 6; rated test current tolerance of 0% to +10% |
| operating error | ±10% | |
| RCD type | AC general purpose 30 mA | |
| Display range | 310 ms | |
| resolution (of a photo) | 0.1 ms | |
| accuracy | 3 ms | |
| Tripping time limit @ 100% (30 mA) | 300 ms | |
| Tripping time limit @ 500% (150 mA) | 40 ms | |
| *The appliance under test is supplied through the mains power supply. | ||
| Environmental indicators | |
| operating temperature | 0 to 40 °C |
| relative humidity | Non-condensing <10 °C |
| 95%, 10 to 30 °C | |
| 75%, 30 to 40 °C | |
| Security Indicators | |
| security level | Conforms to the requirements of EN61010-1 3rd edition |
| CAT II, 300 V, pollution class 2 | |
| Mechanical and general technical specifications | ||
| Dimensions (L x W x H) | 200 x 275 x 114 mm | |
| weights | 3.13 kg | |
| power supply | 230 V +10% -15%, 50 Hz ±2 Hz or (6500-2 only: 110 V +10% -15%, 50 Hz ±2 Hz) | |
| Power consumption (tester) | 13 W typical (standby) 60 W maximum, 25A during ground test |
|
| save | temp | -10 to 60 °C |
| corrode (degrade chemically) | 70 °C @ 95% Rh for up to 5 days | |
| Working altitude | 0 to maximum 2000 m | |
| seal up | IP-40 (housing), IP-20 (connector) | |
| EMC | EN61326-1 compliant, portable | |
| EMI immunity | 3 V/m | |
Model: Fluke 6500-2 Electrical Safety Tester
Fluke 6500-2
Portable Safety Equipment Tester
- Fluke Model 6500-2 Portable Safety Equipment Tester
- Quick Reference Guide
- backpacks
- test line
- Test Probes
- spring clip
- power cable (of an appliance etc)
- USB memory
- USB cable
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.