Product Overview: Fluke 561 Infrared and Contact Thermometer
Infrared thermometer with type K thermocouple function
The Fluke 561 Infrared and Contact Pyrometer combines the temperature measurement capabilities technicians in industrial, power, and HVAC industries need, with both infrared and contact temperature measurement, making it a one-piece solution that can be used in multiple applications. It is fast, efficient and easy to use, saving you valuable time and effort. At the same time, you also have the flexibility to choose between contact and infrared temperature measurement. The infrared thermometer measures heat, motion, electricity, and inaccessible objects in moments, and can be used to check motors, insulation, circuit breakers, radiant heat, piping, corroded joints, wiring faults, and to scan HVAC ductwork and other inaccessible objects without using a ladder. When measuring ducts, you can either use the convenient Velcro® duct probe or utilize the standard Type K mini-connector thermocouple probe you have on hand to measure overheating or internal temperatures.
Product Specification: Fluke 561 Infrared and Contact Thermometer
| common technical specification | |
| temp | -40 to 550 °C (-40 to 1022 °F) |
| Display resolution | 0.1 °C (0.1 °F) of reading |
| D:S (distance ratio of measuring points) | 12:1 |
| Emissivity Quick Selector | It can be adjusted between three settings: |
| Low (0.3), medium (0.7), high (0.95) | |
| Display Accuracy [Assumes ambient operating temperature of 73°F (23°C) to 77°F (25°C) | ±1.0 % reading ±1 % reading or ±1 °C (±2 °F), whichever is greater, below 0 °C/32 °F ±1 °C (±2 °F) ± 0.1°/1° |
| response time | <500 mSec (95% of reading) |
| repetitive | ± 0.5% of reading or ±1 °C (±2 °F), whichever is greater |
| spectral response | 8 µm to 14 µm |
| laser aiming | single point laser |
| Laser off | Laser turns off when ambient temperature exceeds 104 °F (40 °C) |
| laser power | Class 2 (II) operation; output <1 mW at 630-670 nm |
| relative humidity | 10% to 90% RH, non-condensing, < 30 °C (86 °F) |
| Power supply and battery life | 2 AA type batteries (alkaline or nichrome) |
| Battery life | 12 hours |
| The data show that maintaining | 7 seconds. |
| Backlit Display | Yes, dual temperature LCDs (current and MAX/MIN/DIF/KTC temperatures), low battery indication, F/C unit indication, and scan/hold option |
| warranty period | 2 years |
| operating temperature | 0 °C to 50 °C (32 °F to 120 °F) |
| storage temperature | -20 °C to 65 °C (-25 °F to 150 °F) |
| Maximum and minimum temperature and temperature difference | there are |
| Mini-Connector K-Type Thermocouple Input | Yes, compatible with industry standard K-type probes with miniature connectors. Displays pyrometer temperature range. |
| Type K Thermocouple Fabric Hook and Loop Fastener Tube Probe | Yes, temperature range 0 °C to 100 °C (32 °F to 212 °F), accuracy ±2.2 °C (±4 °F) |
| Heating, Ventilation, Air Conditioning and Refrigeration (HVAC) Measurement Guide | there are |
Model: Fluke 561 Infrared and Contact Thermometer
Fluke 561
Fluke 561 Infrared and Contact Thermometer
Includes.
- 561 IR thermometer
- K-Type thermocouple
- Fabric hook-and-loop fastener pipe probe
- Hard carrying case
- 2 AA batteries
- Users manual
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.