SigOFIT Optical Isolation ProbeMOIP Series (Laser Powered)

Bandwidth: 100MHz-1GHz

Common mode voltage: 85kVpk

DC Gain Accuracy: 1%

Common mode rejection ratio: up to 180dB

Interface: Standard BNC

Micsig's MOIP series of optical isolation probes range from 100MHz to 1GHz and can measure differential mode signals from ±0.01V to ±6250V. Based on the exclusive SigOFIT™ leading technology, the MOIP series has a very high common mode rejection ratio of up to 108dB at 1GHz, isolation voltage of up to 85kV, and a noise floor of less than 0.45mVrms, which provides insight into the full truth of the signal within its bandwidth, and is the ultimate arbiter of the authenticity of signals measured by other voltage probes.

MOIP series adopts advanced laser power supply technology, laser signal transmission, laser power transmission (no battery, more pure power supply), 365 days of uninterrupted testing, standard BNC interface, adaptable to all brands of oscilloscopes; seconds of self-calibration, no need to wait, power on the test, without warming up, high stability, temperature drift is very small, accuracy better than 1%, can be switched between 0dB and 20dB, making a single attenuator also has two ranges to improve the signal-to-noise ratio; input capacitance of only 1pF, measuring gallium nitride (GaN) without blowing the tube, attenuator and fiber length can be customized. Make a single attenuator also has two ranges to improve the signal-to-noise ratio; input capacitance of only 1pF minimum, measurement of gallium nitride (GaN) does not blow up the tube, attenuator and fiber length can be customized, can be used to measure SiC/GaN and other power devices, such as the gate voltage drive and other high-voltage and high-frequency challenging scenarios.

The truest signal presentation

The SigOFIT Optical Isolation Probe has an extremely high common mode rejection ratio, with a CMRR of up to 128dB at 100MHz and still up to 108dB at 1GHz, making it the ultimate arbiter of the authenticity of signals measured by other voltage probes.

Optically Isolated Probes

Extremely high test accuracy and stability

As the ultimate judge of the authenticity of signals measured by other voltage probes, test accuracy is an important indicator of SigOFIT optical isolation probes, which have excellent amplitude-frequency characteristics, DC gain accuracy of better than 1%, noise floor of less than 0.45mVrms, zero drift after warm-up for 5min of less than 0.1%, gain drift of less than 1%.

Optically Isolated Probes

Optimal Test Means for Third Generation Semiconductors

Third-generation semiconductor devices due to the short on and off time, the signal has a faster rising edge and falling edge, the signal has a high energy of high-frequency harmonics, SigOFIT optical isolation probe in the highest bandwidth, but still has a common mode rejection ratio of more than 100dB, can be nearly perfect suppression of high-frequency common-mode noise generated by the oscillation of the signal presented by the signal without additional redundant components, it is the third-generation semiconductor It is the perfect choice for third-generation semiconductor testing.

Optically Isolated Probes

Testing Gallium Nitride (GaN) without Blowing Tubes

SigOFIT opto-isolated probes are safe for testing Gallium Nitride (GaN) with short test leads and coaxial transmission and a minimum probe input capacitance of only 1pF.

Optically Isolated Probes

Flexible, efficient and easy to use

SigOFIT optical isolation probe than the traditional high-voltage differential probe volume is smaller, the probe lead is more compact, more flexible and convenient to use; probe response is fast, power on that is measured, the calibration time is less than 1 second, calibration, without the need to disconnect the test connection, can be real-time to ensure that the accurate signal output.

McKesson Optical Isolation Probes

True Optical Isolation Technology

Transmitting signal with laser + transmitting power with laser (no batteries, purer power supply) for 365 days of uninterrupted testing.

Wider test range

Unlike high-voltage differential probes that can only test high-voltage signals, SigOFIT optical isolation probes can test differential mode signals from ±0.01V to ±6250V by matching different attenuators and achieve full-scale output to achieve a high signal-to-noise ratio.

Optically Isolated Probe OP

application scenario

The SigOFIT Optical Isolation Probe can be used as the final arbiter when there is a question as to the accuracy and veracity of the results measured by other voltage probes.

Power Supply Device Evaluation, Current Parallel Measurement, EMI and ESD Troubleshooting

Motor drive design, power converter design, electronic ballast design

Design and analysis of Gallium Nitride, Silicon Carbide, and IGBT half/full bridge devices

Secure Isolation Testing for High Voltage High Bandwidth Test Applications

Testing of inverters, UPS and switching power supplies

Wide voltage, wide bandwidth test applications

Various Floating Ground Tests

Optically Isolated Probes

model number MOIP100P MOIP200P MOIP350P MOIP500P MOIP800P MOIP1000P
bandwidths 100MHz 200MHz 350MHz 500MHz 800MHz 1GHz
rising time ≤3.5ns ≤1.75ns ≤1ns ≤700ps ≤500ps ≤450ps
Common mode rejection ratio DC: 180dB
100MHz: 128dB
DC: 180dB
200MHz: 122dB
DC: 180dB
350MHz: 118dB
DC: 180dB
500MHz: 114dB
DC: 180dB
800MHz: 110dB
DC: 180dB
1GHz: 108dB
Test Voltage Range Standard OP20 (MMCX), ±25V
Optional OP50 (MMCX), ±62.5V
Optional OP200(MCX), ±250V
Optional OP1000(MCX), ±1250V
Optional OP2000 (MCX), ±2500V
Optional OP5000(LCX), ±6250V
Standard OP20 (MMCX), ±25V
Optional OP50 (MMCX), ±62.5V
Optional OP200(MCX), ±250V
Standard OP1000 (MCX), ±1250V
Optional OP2000 (MCX), ±2500V
Optional OP5000(LCX), ±6250V
Optional OP20 (MMCX), ±10V
Standard OP50 (MMCX), ±25V
Optional OP100 (MMCX), ±50V (MOIP500P only)
Standard with OP2000 (MCX), ±1000V
Optional OP5000(MCX), ±2500V
Optional OP10000(LCX), ±5000V
bottom noise <0.45mVrms
DC Gain Accuracy 1%
common-mode voltage (electronics) 85kVpk