Product Features
♦ Frequency range: 45~450HZ
Power range: 0-14.4kVA
Voltage range: 15~260Vrms, 50~420Vrms
Current range: 0-160 Arms
Parallel/three-phase control *1
♦ 7-inch LCD display
Oscilloscope waveform display function, displaying voltage and current waveforms
♦ High-speed AD sampling, real-time waveform capture
Measure Vrms/Vpk/Vdc/Irms/Ipk/Idc/W/VA/VAR/CF/PF/FREQ.
THD(V) parameters can be measured up to 50 times.
♦ AC electronic load: CC /CR/CP mode
DC electronic loads: CC/CR/CP/CV mode *2
External 0-10V analog control, voltage, current analog monitoring function *3
OTP/OCP/OVP/UVP/OPP protection function
LAN/USB communication interface, external USB disk interface
*1 IT8616 does not have this function, IT8617 can switch between single and three phases.
*2 CV mode for IT8615/IT8615L only
*3 External analog capability for IT8615 and IT8615L only
Product Features and Benefits
Scope of Application

Simultaneous display of multiple parameters
The IT8600 provides users with a 7-inch LCD display screen and a user-friendly graphical display interface, which not only allows you to view multiple parameters at the same time, but also allows you to choose from a variety of display modes, such as waveforms, bar graphs and lists, which opens up a whole new feeling of use and fully takes into account the various measurement needs of engineers in different tests.

Harmonic measurement and analysis function
The IT8600 provides powerful data measurement functions, in addition to measuring conventional parameters such as Vrms, Vpk, Vdc, Irms, Ipk, Idc, W, VA, VAR, CF, PF, Freq, etc., it also provides a unique voltage harmonic analysis function to verify the object to be measured (uninterruptible power supply UPS, generator, etc.). For harmonic disturbances in the power grid, it has the function of analyzing up to 50th voltage harmonics, and can display the analysis results in different forms to show the percentage of each harmonic.

Oscilloscope waveform display function
IT8600 unique oscilloscope waveform display function, you can choose to display or hide the input voltage and current waveforms of the object to be measured, and observe only the necessary waveforms on the screen, which is more intuitive. You can also use the user-friendly screenshot function key to take a screenshot of the current screen image and save it to the peripheral device storage disk through the front USB interface, which is convenient for secondary analysis of data and waveforms.

Parallel/three-phase control
The IT8600 provides multiple parallel, three-phase and parallel three-phase functions, which can realize the testing of three-phase AC power supply or higher power supply applications. In three-phase parallel connection, users can realize Y-type and Δ-type connection according to the actual needs, and the IT8600 can also realize 380V AC input, which is universally used to meet diversified testing needs.
(* IT8616 does not have this function, IT8617 can switch between single and three phases)

| model number | input voltage | amps | power (output) | resolution (of a photo) | mythical goblin spirit degree (angles, temperature etc) | take over for sb. mouth | sizes |
|---|---|---|---|---|---|---|---|
| IT8615 | 50~420V | 20A | 1800VA | 10mV/1mA | ±(0.1%+0.2%FS) | LAN/USB | 3U |
| IT8615L | 15~260V | 20A | 1800VA | 10mV/1mA | ±(0.1%+0.2%FS) | LAN/USB | 3U |
| IT8616 | 50~420V | 40A | 3600VA | 10mV/1mA | ±(0.1%+0.2%FS) | LAN/USB | 6U |
| IT8617 | 50~420V | 60A | 5400VA | 10mV/1mA | ±(0.1%+0.2%FS) | LAN/USB | 15U |
| IT8624 | 50~420V | 80A | 7200VA | 10mV/10mA | ±(0.2%+0.2%FS) | LAN/USB | 27U |
| IT8625 | 50~420V | 100A | 9000VA | 10mV/20mA | ±(0.5%+0.5%FS) | LAN/USB | 27U |
| IT8626 | 50~420V | 120A | 10.8kVA | 10mV/20mA | ±(0.5%+0.5%FS) | LAN/USB | 27U |
| IT8627 | 50~420V | 140A | 12.6kVA | 10mV/40mA | ±(0.5%+0.5%FS) | LAN/USB | 37U |
| IT8628 | 50~420V | 160A | 14.4kVA | 10mV/40mA | ±(0.5%+0.5%FS) | LAN/USB | 37U |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.