TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester
TH9110 programmable programmable AC/DC withstand voltage and insulation tester

TH9110 programmable programmable AC/DC withstand voltage and insulation tester

TH9110/TH9110A AC/DC Withstand Voltage/Insulation Resistance Tester is the same as the Hui many years of experience in the design of electrical safety test equipment, the latest design with 500VA high power, maximum output AC 5kV/100mA, in line with the needs of high-power voltage testing, as well as in line with EN50191 equipment safety standards.

Categories. , Tags. , Brand.

Inquire about this product

TH9110/TH9110A AC/DC Withstand Voltage/Insulation Resistance Tester is the same as the Hui many years of experience in the design of electrical safety test equipment, the latest design with 500VA high power, maximum output AC 5kV/100mA, in line with the needs of high-power voltage testing, as well as in line with EN50191 equipment safety standards.

TH9110/TH9110A series, in addition to the basic AC, DC, insulation resistance test, increased the crash voltage test function, can analyze the breakdown point voltage of the product, to meet the requirements of specific customers on the product of high-voltage reliability testing; at the same time, with the open and short-circuit detection function, solves the user in the test of safety products in the reliability and accuracy of the issue of synchronization of the output contact check, to avoid the leakage of the test reliability and efficiency. It also has the function of open-short-circuit detection, which solves the problem of reliability and accuracy when testing safety products.

TH9110/TH9110A use 7-inch LCD color display, and the test results will be displayed in large characters, more clear and intuitive, easy to operate and judge. At the same time floating ground output design, electric shock protection function, etc., more to ensure that the customer even in the accidental contact with the high-voltage test terminal will not be electrocuted when the injury, to protect the safety of the operator, the operation of the worry-free.

Functional Features

A. Voltage withstand insulation test and arc detection (ARC)

Poor voltage withstand means that there should be no electrical flashover or insulation damage during the voltage withstand test. Nowadays, voltage withstand insulation test has become the standard equipment for all kinds of insulation material testing. However, just considering insulation failure is not a complete solution to product safety problems, another type of phenomenon, which is getting more and more attention in voltage withstand testing nowadays, is discharge, which has a very high correlation between discharge and insulation capability, so discharge detection is not only an important related issue, but also the main key to control product quality.

 

Arc Discharge .

 

Arc discharge occurs in the following two situations

1. When the material is subjected to high voltage, the electric field strength is relatively large, and the electric field strength is greater than the ionization energy of the gas, the gas on the surface of the material will undergo transient ionization phenomenon, which will form a fire on the surface of the material and form a temperature rise phenomenon on the material. Prolonged ignition and temperature rise may cause material quality change, which in turn leads to insulation degradation, making the voltage tolerance degree decrease, and ultimately insulation failure occurs.

2. When the distance between the detection points of the tested parts is too small, and a higher voltage is applied to the two ends of the tested parts, the air in the space between the two ends of the detection points will be ionized, resulting in the phenomenon of ignition, that is, the phenomenon of pulling the arc.

1601188175811923

Due to the arc phenomenon produces high-frequency transient discharge, such as Figure 1, is generated in the test process of a high-frequency current signal, this high-frequency signal is greater than the normal test signal, so it will cause a misjudgment, so the arc detection (ARC) function is a high-frequency power measurement detection, on the one hand, you can determine whether the material insulation of the new ability to be bad, and on the other hand, can prevent the misjudgment.

B. Contact check function OSC

 

In the process of withstand voltage test due to the oxidation of the contact point of the tested parts, test line damage, etc., will occur open circuit phenomenon, which will lead to defective products misjudged as good products; at the same time, the tested parts are damaged or the spacing between the tested ends is too small leading to short circuit phenomenon of the test line, the instrument can be known and screened in advance, reducing the damage to the fixtures and equipment to save the cost of the test.

1601188371108319-1

 

Therefore, it is possible to reduce the occurrence of poor contact problems on the production line by utilizing the judgment of the upper and lower limit values of the change in capacitance.

C. Insulation collapse detection

Conventional test withstand voltage, as shown in Figure 2, just set the rise time and test voltage value, if the test time, the measured part of the breakdown phenomenon, it will be judged that the withstand voltage is bad, directly cut off the test voltage. Therefore, the conventional withstand voltage test can only judge whether the withstand voltage is qualified under the pointing voltage.

1601188699940201-1

However, there are some passive components or materials that need to be tested for their high voltage withstand level and derive an accurate value of the crash voltage, then the conventional voltage withstand detection methods can't help. Therefore the TH9110/A adds a crash voltage detection function, as shown in Figure 3:

1601188793127374-1

 

As can be seen from the figure, the collapse voltage test function is based on the set climbing start voltage, end voltage, voltage step and time interval, and gradually measure the measured parts, when the measured parts appear to withstand the phenomenon of poor insulation, automatically save the voltage value at this time, that is, the collapse voltage; if the voltage value climbs to the cut-off voltage, the measured parts still do not appear to collapse, you can reset the cut-off voltage, etc., to carry out further Analysis, until the correct value of the collapse voltage. Therefore, the collapse voltage test mode can be used to analyze the component under test, so that researchers can improve the insulation of the component where it is weak.

D. Super Safety Design - Floating Ground Output Function / Electrocution Protection Function

 

The purpose of safety testing is to protect the user of the product, and when the operator is operating the instrument, it also needs to be protected by the design of the instrument.The TH9110/A is designed with two types of protection safety design for choice, namely the floating ground output and the electric shock protection function.

Floating ground output function:

1601189023126625

As shown in Figure 4, when the human body accidentally touches the high-voltage end of the test, the low end of the high-voltage circuit (RETURN) is not grounded, but isolated from the ground, equivalent to access to a highly insulated resistor, so that the current through the human body will not be greater than 3.5mA, thus ensuring the safety of the test personnel.

The design complies with the EN50191 equipment safety standard.

Electric shock protection function:

1601189098697674

 

As in Fig. 5, when the operator is electrocuted, the ammeter measures different values respectively, and the current I3= i2-i1 through the human body, when i3 is too high, it is judged to be electrocuted, and the output will be cut off immediately to guarantee the safety of users.

model number TH9110 TH9110A
Pressure resistance test
output voltage AC voltage range 0.05 ~ 5.0kV
Voltage waveform 50/60Hz ±0.1% sine wave
output power 500VA (5.0kV 100mA)
DC voltage range 0.05 ~ 6.0kV
output power 150VA (6.0kV 25mA)
Load variability ± (1% setpoint + 0.2% full scale) (rated power)
Voltage Accuracy 1% setpoint + 0.1% full scale
Voltage Resolution 2V
Current Test Range AC current range 0.001mA-120mA (voltage ≤4kV) 0.001mA-100mA (voltage >4kV)
Current Resolution 0.001mA
Current Accuracy ± (1% reading + 0.5% full scale)
DC current range 0.0001mA-25mA (voltage ≥1.5kV) 0.0001mA-20mA (voltage <1.5kV)
Current Resolution 0.1uA
Current Accuracy ± (1% reading + 0.5% full scale)
Maximum short-circuit current 200mA (AC test only)
Rapid Discharge Function Automatic discharge at the end of the test (DCW)
Insulation resistance test
output voltage DC : 0.05 ~ 5.0kV
Voltage Resolution 2V
Voltage Accuracy 1% of setpoint + 0.1% full scale
Resistance Test Range 1MΩ-50.0GΩ
Resistance Resolution 0.1MΩ
Resistance Test Accuracy Voltage >1000V 1MΩ ~ 1GΩ : ± (3% + 0.1% full scale)

1GΩ ~ 10GΩ : ± (7% + 2% full scale)

10GΩ ~ 50GΩ : ± (10% + 1% Full Scale)

Voltage≧500V ,≦1kV 0.1MΩ ~ 1GΩ : ± (3% + 0.1% full scale)

1GΩ ~ 10GΩ : ± (7% + 2% full scale)

10GΩ ~ 50GΩ : ± (10% + 1% full scale)

Voltage <500V 0.1MΩ ~ 1GΩ : ± (3% + (0.2*500/Vs)% range)
Rapid Discharge Function Automatic discharge at the end of the test
arc detection
Program settings AC 1mA - 20mA
DC 1mA - 10mA
OSC open/short circuit detection
Sampling standard capacitance range 0.001~40nF
Open Circuit Judgment Range 10% to 100%
Short Circuit Judgment Range 100% to 500%
time setting
Testing time 0.3~999s, 0 means continuous test
rising time 0.1~999s, 0 means off
descent time 0.1~999s, 0 means off
waiting time 0.1 to 999s, 0 means off (DC withstand voltage only)
Safety and security features
High Voltage Floating Output test pattern ACW, DCW, IR ----------
leakage current <3.5mA ac/dc
electrocution protection 0.5mA ±0.25mA selectable: on or off
Startup Protection Interlock High-voltage output is allowed only when the pin is connected low
Panel operation protection Keylock, Combination
warning indication Pass: short tone, green light; Fail: long tone, red light
Storage and Interfaces
internal memory 100 files can be stored and 50 steps can be edited per file
Standard Interface RS232, USB DEVICE, USB HOST, LAN, HANDLER
Optional Interfaces GPIB
Ambient temperature and humidity
Parameter comparison temperature 18℃~28℃, Humidity: 30%~70%RH
normal working temperature 0℃~45℃, Humidity: 20%~90%RH
Storage ambient temperature -10℃~55℃, Humidity:< 80%RH
General indicators
power supply 100V~240VAC, 47Hz~63Hz
power (output) No load:< 100W Rated power:1000W
sizes 430mm (W) x 132mm (H) x 500mm (D)
weights 21Kg

■ High power: AC 5kV/100mA/500VA output

■ High resolution: 7-inch 800 x 480 dot, TFT-LCD display

■ New operator interface, Chinese and English menus

■ Arc ARC detection function

■ OSC check function

■ Crash voltage test function

■ One-click screenshot function

■ Rear panel output function for automated production line testing

■ Storage: 100 files with up to 50 steps per file

■ High security:

High-voltage floating output designed to meet the safety requirements of the European Union standard EN50191 (TH9110 only)

Electric shock protection function

■ Transformers

Power transformers need to check whether the main insulation is qualified, that is, the insulation condition between the primary and secondary coils, between them and the core and shell. If it is not qualified, it will not only jeopardize the damage of the transformer itself and other electrical devices connected to it, but also cause danger to the equipment and personnel using electricity. Transformer voltage withstand test includes primary side and secondary pole withstand voltage, primary side and grounding withstand voltage, secondary side and grounding withstand voltage, primary side, secondary side of the coil of the interlayer short-circuit test, the primary side, the secondary side and grounding of the leakage current test, if the transformer has a number of primary or secondary side coils, the test process will be very complex, so researchers and developers in the early stages of the product design, we must pay attention to whether the transformer Therefore, in the early stage of product design, researchers should pay attention to whether the transformer is in line with the product safety standards of the transformer-related provisions, as well as in the production of test efficiency and cost considerations.

▪ Generators/motors and other wire-wound devices.

Demand for higher power and leakage current products with withstand voltage testing and analysis, such as various types of motor stator, rotor and other products with high parasitic capacitance.

▪ Electronic components.

Includes capacitors, coils, cores, chokes, filters, etc.

■ Electrical products

Household appliances, information products, audio-visual equipment, etc.

■ Non-electrical products

Voltage and insulation resistance testing of wires, non-woven fabrics, insulating materials, etc.

■ new energy vehicle

■ Automated test systems

standard equipment
Accessory Name model number
High Voltage Test Cables TH90018
Expand More
TH9110 programmable programmable AC/DC withstand voltage and insulation testerTH9110 programmable programmable AC/DC withstand voltage and insulation tester

Click to enquire

Product consultation and purchase:18218718851