-Helps with failure analysis at the test site
-Improve work efficiency! Saving of measuring man-hours through electronic management (Excel® direct input function)
-Designed to prevent misplugging of test cables for safe and secure testing (terminal protection function)
-Integrated test lead and test sheath
-High dust and waterproof rating (IP54)
Product Feature Name
CAT III 1000V, CAT IV 600V
Basic parameters
Accuracy is guaranteed for 1 year.
※About the accuracy of the DMM: Since the digital multimeter has many measurement functions and ranges, the basic accuracy stated is only a representative value. For the accuracy of each range, please refer to the PDF of the product manual.
| dc voltage | 600.0 mV to 1000 V, 5 ranges, basic accuracy: ±0.15 % rdg. ±2 dgt. |
|---|---|
| AC Voltage 40~500Hz | 6.000 V to 1000 V, 4 ranges, Frequency: 40 Hz to 1 kHz Basic accuracy 40 Hz - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
| DC + AC Voltage | 6.000 V~1000 V, 4 ranges, Frequency: DC,40 Hz~1 kHz Basic accuracy DC, 40 Hz - 500 Hz : ±1.0 % rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
| LoZ V | 600.0 V, 1 range, Frequency: DC, 40 Hz ~ 1 kHz Basic accuracy DC, 40 Hz - 500 Hz : ±1.0 % rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
| resistive | 600.0 Ω ~ 60.00 MΩ, 6 ranges, basic accuracy: ±0.7 % rdg. ±3 dgt. |
| direct current | 600.0 mA to 10.00 A, 3 ranges, basic accuracy: ±0.5 % rdg. ±3 dgt. |
| alternating current (electricity) | 600.0 mA to 10.00 A, 3 ranges, basic accuracy 40 Hz - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3 or less) Frequency Characteristics: 40 Hz ~ 1 kHz |
| AC current (measured by AC clamp-on probe) | 10.00 A to 1000 A, 7 ranges, basic accuracy 40 Hz - 500 Hz : ±0.9 % rdg. ±3 dgt. plus measurement accuracy of clamp-on probes (True RMS, crest factor 3 or less) |
| capacitive coupling | 1.000 μF to 10.00 mF, 5 ranges, basic accuracy: ±1.9 % rdg. ±5 dgt. |
| conductivity check | Conductivity ON Threshold: 25 Ω, Conductivity OFF Threshold: 245 Ω, Response Time: 0.5 ms or more |
| Diode Testing | Open Circuit Voltage: 2.0 V or less, Test Current: 0.2 mA, Clockwise Threshold: 0.15 V ~ 1.8 V |
| Voltage Frequency | 99.99 Hz ~ 99.99 kHz, 4 ranges (depending on minimum sensitivity voltage) Basic accuracy: ±0.1 % rdg. ±1 dgt. |
| current frequency | 99.99 Hz to 9.999 kHz, 3 ranges (depending on minimum sensitivity current) Basic accuracy: ±0.1 % rdg. ±1 dgt. |
| harmonic (wave with frequency an integer multiple of the fundamental) | Harmonic level/content/total harmonic distortion up to the 30th order in the current can be measured [when Z3210 is installed]. * :: Can be displayed using application software (GENNECT Cross) |
| Other Functions | Foolproof insertion prevention function, Fuse check function, User setting hold function, Filter function, Auto zero, Display value hold, Auto hold, Maximum/minimum value display, Transient value (PEAK) display, Auto power save, USB communication (only when the optional communication package DT4900-01 is installed), Wireless communication (only when the optional wireless adapter Z3210 is installed) |
| demonstrate | 4-digit LCD, max. 6000 dgt. (except frequency measurement), bar graph |
| Display update rate | 5 cycles/s (capacitive coupling: 0.05 to 5 cycles/s depending on measured value, frequency: 1 to 2 cycles/s) |
| power supply | Alkaline dry batteries (LR6) × 3, Continuous use time: 130 h (without Z3210 installed), 70 h (with Z3210 installed, wireless communication) |
| Volume and weight | 87W × 185H × 47D mm, 480 g (including test lead holder, battery) |
| attachment (email) | Test Lead L9300 ×1, Instruction Manual ×1, Alkaline Dry Battery No. 5 (LR6) ×3, Precautions for Use ×1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.