GDM-906X Series Digital Multimeter
GDM-906X Series Digital Multimeter
GDM-906X Series Digital Multimeter
GDM-906X Series Digital Multimeter
GDM-906X Series Digital Multimeter
GDM-906X Series Digital Multimeter

GDM-906X Series Digital Multimeter

This product is currently out of stock and unavailable.

  • 6 ½ digital display: 1,200,000
  • 4.3″ TFT LCD
  • DCV basic accuracy: 0.0035% (GDM-9061)/0.0075% (GDM-9060)
  • 12 measurement functions: DCV, ACV, DCI, ACI, 2-wire and 4-wire resistance, frequency, period, diode, continuity, temperature and capacitance.
  • Sampling rate up to 10k SPS (GDM-9061)
  • Dual measurement to perform two selected measurements simultaneously
  • Provides functionality including histograms, bar charts and trend charts
  • Temperature measurement support for RTDs, thermistors and thermocouples
  • Standard Interface: USB, RS232C, LAN, Digital I/O
  • Optional interface: GPIB

GDM-906X series (2 models ~ GDM-9061 and GDM-9060), 6 ½ digit dual measurement digital meter with high precision DC current measurement, fast sampling rate, 12 measurement items (DC voltage/current, AC voltage/current, 2-wire/4-wire resistance, frequency, cycle, diode, short-circuit buzzer, temperature, capacitance), 6 measurement items (dB/dBm/Compare/MX+B/Percent and 1/X), and rich communication interfaces (USBdevice/host, RS+B/Percent and 1/X). operation functions (dB/dBm/Compare/MX+B/Percent and 1/X), and a rich set of communication interfaces (USBdevice/host, RS-232C, LAN, digital I/O, and GPIB optional), providing a full range of measurement capabilities, as well as higher speed and accuracy. With a 4.3-inch TFT graphic display and fast sampling rates (GDM-9061: 10k/s, GDM-9060: 1k/s max.), the series can be used to display bar graphs, trend graphs, or histograms in addition to traditional digital displays, making the entire measurement process more intuitively and quickly presented in its entirety. At the same time, the larger memory (GDM-9061:100k, GDM-9060:10k) also assists in the statistical calculation of trend graphs or histograms during the measurement process, simplifying the tedious trend analysis. In terms of ease of use, the GDM-906X series also incorporates a wealth of operational designs, such as numeric buttons for easy setup that require numeric inputs, such as upper/lower limit values, LAN IP...etc.; and operational interfaces or messages that support multiple languages (English/Traditional/Simplified/Japanese/Korean), which helps to shorten the meter's operational learning curve. For automatic test system measurement or remote control applications, the GDM-906X provides USB, RS-232C and LAN as standard communication interfaces in addition to GPIB (customer installation option). In terms of software support, the GDM-906X series provides DMM-Viewer2 to assist users in observing or recording measurement data, and LabVIEW driver to facilitate different system integration program requirements.

GDM-9061 Multiple Display Modeshttps://v.youku.com/v_show/id_XNDYyMTc4NjYyMA==.html

GDM-906X Data Logginghttps://v.youku.com/v_show/id_XNDYyMTc4NjAzNg==.html

GDM-9061 Demo Videohttps://v.youku.com/v_show/id_XNTAxOTkzNTY1Mg==.html

Quick Selection

model number sampling rate demonstrate DCV Accuracy Maximum current level Rear Panel Inputs Standard Interface
GDM-9060 1K/sec 6½ Dual Display (1200000) 0.0075% 3A NO USB/RS-232/LAN/I/O
GDM-9061 10K/sec 6½ Dual Display (1200000) 0.0035% 10A YES USB/RS-232/LAN/I/O
GDM-8261A 2.4K/sec 6½ Dual Display (1200000) 0.0035% 10A NO USB/RS-232/I/O

 

Detailed specifications

DC Characteristics
dc voltage
gear level (i.e. first gear, high gear etc) resolution (of a photo) input resistance Accuracy (1 year) (TCAL ± 5°C)
GDM-9061 GDM-9060
100.0000 mV 0.1μV 10MΩor >10GΩ 0.0050 + 0.0035 0.0090 + 0.0065
1.000000 V 1μV 10MΩor >10GΩ 0.0048 + 0.0007 0.0080 + 0.0010
10.00000 V 10μV 10MΩor >10GΩ 0.0035 + 0.0005 0.0075 + 0.0005
100.0000 V 0.1mV 10MΩ±1% 0.0050 + 0.0006 0.0085 + 0.0006
1000.000 V 1mV 10MΩ±1% 0.0050 + 0.0010 0.0085 + 0.0010
Resistance Grades resolution (of a photo) Test Current Accuracy (1 year) (TCAL ± 5°C)
  GDM-9061 GDM-9060
100.0000 Ω 100μΩ 1mA 0.010 + 0.004 0.014 + 0.007
1.000000 kΩ 1mΩ 1mA 0.010 + 0.001 0.014 + 0.001
10.00000 kΩ 10mΩ 100μA 0.010 + 0.001 0.014 + 0.001
100.0000 kΩ 100mΩ 10μA 0.010 + 0.001 0.014 + 0.001
1.000000 MΩ 5μA 0.010 + 0.001 0.014 + 0.001
10.00000 MΩ 10Ω 500nA 0.040 + 0.001 0.040 + 0.001
100.0000 MΩ 100Ω 500nA 0.800 + 0.010 0.800 + 0.010
direct current
gear level (i.e. first gear, high gear etc) resolution (of a photo) Burden Voltage Accuracy (1 year) (TCAL ± 5°C)
  GDM-9061 GDM-9060
100.0000 μA 100pA < 0.011 V 0.05 + 0.025 0.05 + 0.025
1.000000 mA 1nA < 0.11 V 0.05 + 0.006 0.05 + 0.006
10.00000 mA 10nA < 0.04 V 0.05 + 0.020 0.05 + 0.020
100.0000 m A 0.1μA < 0.4 V 0.05 + 0.005 0.05 + 0.005
1.000000 A 1μA < 0.7 V 0.10 + 0.010 0.10 + 0.010
3.000000 A 1μA < 2.0 V 0.20 + 0.020 0.20 + 0.020
10.00000 A 10μA < 0.5 V 0.15 + 0.010 ------------------
 
contiguity resolution (of a photo) Test Current Accuracy (1 year) (TCAL ± 5°C)
  GDM-9061 GDM-9060
1000.000 Ω 0.001 Ω 1 mA 0.010 + 0.030 0.014 + 0.030
Diode Testing
gear level (i.e. first gear, high gear etc) resolution (of a photo) Test Current Accuracy (1 year) (TCAL ± 5°C)
  GDM-9061 GDM-9060
5.000000 V 1μV 1 mA 0.010 + 0.030 0.014 + 0.030
DC Ratio
Accuracy specification: ± (DC input accuracy + DC reference accuracy)
AC Characteristics
AC Voltage (True RMS)
gear level (i.e. first gear, high gear etc) resolution (of a photo) frequency Accuracy (1 year) (TCAL ± 5°C)
  GDM-9061 GDM-9060
100.0000 mV 0.1μV 3 Hz - 5 Hz 1.00 + 0.04 1.00 + 0.04
5 Hz - 10 Hz 0.35 + 0.04 0.38 + 0.04
10 Hz - 20 kHz 0.06 + 0.04 0.09 + 0.04
20 kHz - 50 kHz 0.12 + 0.05 0.15 + 0.05
50 kHz - 100 kHz 0.60 + 0.08 0.63 + 0.08
100 kHz - 300 kHz 4.00 + 0.50 4.00 + 0.50
1.000000 V to 750.000 V 1μV ~ 1mV 3 Hz - 5 Hz 1.00 + 0.04 1.00 + 0.04
5 Hz - 10 Hz 0.35 + 0.04 0.38 + 0.04
10 Hz - 20 kHz 0.06 + 0.04 0.09 + 0.04
20 kHz - 50 kHz 0.12 + 0.05 0.15 + 0.05
50 kHz - 100 kHz 0.60 + 0.08 0.63 + 0.08
100 kHz - 300 kHz 4.00 + 0.50 4.00 + 0.50
AC Current (True RMS)
gear level (i.e. first gear, high gear etc) resolution (of a photo) frequency Accuracy (1 year) (TCAL ± 5°C)
  GDM-9061 GDM-9060
100.0000 μA 10.00000 mA 100pA 10nA 3 Hz - 5 Hz 1.00 + 0.04 1.00 + 0.04
5 Hz - 10 Hz 0.35 + 0.04 0.38 + 0.04
10 Hz - 5 kHz 0.10 + 0.04 0.13 + 0.04
5 kHz-10 kHz 0.18 + 0.04 0.20 + 0.04
1.000000 mA100.0000 mA 1nA100nA 3 Hz - 5 Hz 1.00 + 0.04 1.00 + 0.04
5 Hz - 10 Hz 0.30 + 0.04 0.33 + 0.04
10 Hz - 5 kHz 0.10 + 0.04 0.13 + 0.04
5 kHz-10 kHz 0.15 + 0.04 0.18 + 0.04
1.000000 A 1μA 3 Hz - 5 Hz 1.00 + 0.04 1.00 + 0.04
5 Hz - 10 Hz 0.30 + 0.04 0.33 + 0.04
10 Hz - 5 kHz 0.10 + 0.04 0.13 + 0.04
5 kHz-10 kHz 0.15 + 0.04 0.18 + 0.04
3.000000 A 1μA 3 Hz - 5 Hz 1.00 + 0.04 1.00 + 0.04
5 Hz - 10 Hz 0.35 + 0.04 0.38 + 0.04
10 Hz - 5 kHz 0.23 + 0.04 0.23 + 0.04
5 kHz-10 kHz 0.23 + 0.04 0.23 + 0.04
10.00000 A 10μA 3 Hz - 5 Hz 1.10 + 0.04 ------------------
------------------
10 Hz - 5 kHz 0.15 + 0.04 ------------------
------------------
temperature characteristic
RTD (PT100-based accuracy)
gear level (i.e. first gear, high gear etc) resolution (of a photo) Accuracy (1 year) (TCAL ± 5°C)
-200℃~-100℃ 0.001°C 0.09°C
-100℃~-20℃ 0.001°C 0.08°C
-20℃~20℃ 0.001°C 0.06°C
20℃~100℃ 0.001°C 0.08°C
100℃~300℃ 0.001°C 0.12°C
300℃~600℃ 0.001°C 0.22°C
Thermocouple thermometers (ITS-90 based accuracy)
typology gear level (i.e. first gear, high gear etc) resolution (of a photo) Accuracy (1 year) (TCAL ± 5°C)
E -200℃~+1000℃ 0.002°C 0.2°C
J -210℃~+1200℃ 0.002°C 0.2°C
T -200℃~+400℃ 0.002°C 0.3°C
K -200℃~+1372℃ 0.002°C 0.3°C
N -200℃~+1300℃ 0.003°C 0.4°C
R -50℃~+1768℃ 0.01°C 1°C
S -50℃~+1768℃ 0.01°C 1°C
B +350℃~+1820℃ 0.01°C 1°C
Thermistor ((2.2kΩ, 5kΩ, 10kΩ or User Type))
gear level (i.e. first gear, high gear etc) resolution (of a photo) Accuracy (1 year) (TCAL ± 5°C)
-80℃ ~150℃ 0.01°C 0.01°C
Capacitor Characteristics
capacitors
gear level (i.e. first gear, high gear etc) resolution (of a photo) Accuracy (1 year) (TCAL ± 5°C)
1.000 nF 0.001nF 2.00 + 2.00
10.00 nF 0.01nF 2.00 + 1.00
100.0 nF 0.1nF 2.00 + 0.40
1.000 μF 0.001μF 2.00 + 0.40
10.00 μF 0.01μF 2.00 + 0.40
100.0 μF 0.1μF 2.00 + 0.40
Frequency and period characteristics
Frequency/period
gear level (i.e. first gear, high gear etc) resolution (of a photo) Accuracy (1 year) (TCAL ± 5°C)
100.0000mV~750.000V 3Hz - 5Hz 0.1
5Hz - 10Hz 0.05
10Hz - 40Hz 0.03
40Hz - 1MHz 0.006

Size & Weight: 267(W)*107(H)*302(D)mm, about 3.5kg

 

replacement (parts)
Safety instructions×1, Power cord×1, USB cable GTL-246×1, Test cable GTL-207A×1,
CD x 1 (includes complete instruction manual, upgrade program and PC software, DMM-Viewer2)

optional
GTL-205 Temperature measuring wire adapter with thermocouple (K-type), approx. 1000mm
GTL-234 RS-232C Cable, 9-pin F-F Type, Straight, 2000mm
GTL-248 GPIB cable, about 2000mm

GTL-308 4-wire (+shield) test lead, approx. 1500 mm

GRA-422 Rack (19", 2U)

GDM-TL1 Test Lead Set (for all meter series)
GSC-014 Meter Accessory Kit

 

Ordering Information

GDM-9061 6 ½ (1200000 counts) Digital Dual Measurement Multimeter
GDM-9060 6 ½ (1200000 counts) Digital Dual Measurement Multimeter

options (as in computer software settings)
Opt.1 GPIB card (*) GPIB can be installed at the customer's site

Expand More
GDM-906X Series Digital MultimeterGDM-906X Series Digital Multimeter

Click to enquire

Product consultation and purchase:18218718851

I already understand