Safety testing with perfect insight
GPT-12000 Series 200VA Electrical Safety Analyzer
Alternating Current Withstand Voltage Test (ACW), Direct Current Withstand Voltage Test (DCW), Insulation Resistance Test (IR), Ground Bonding Impedance Test (GB)
The entire lineup offers 4 models
Safety testing must be safe
GPT-12000 series electrical safety analyzers provide up to AC 200VA output capacity and comply with IEC61010-2-034 standard (Safety requirements for electrical equipment for measurement/control and laboratory use I. Special requirements for insulation resistance measuring equipment and compressive strength testing equipment).
We provide safety regulations for testing various electronic/electrical products or components as required by IEC, EN, UL, CSA, GB, JIS, and others.
We emphasize the safety of the user during safety testing and provide safety locks, multiple remote control methods, and safe discharge.
Safety testing must emphasize accuracy
The GPT-12000 series electrical safety analyzers offer a wide range of voltage/current settings, providing higher measurement resolution.
Output settings/measurement ranges: AC withstand voltage test (AC 5kV/40mA max), DC withstand voltage test (DC 6kV/10mA max), insulation resistance test (DC 1200V/50GΩ max), grounding resistance test (AC 32A/650mΩ max), and grounding conductivity test (DC100mA/70Ω max).
Measurement Resolution (AC Withstanding Voltage: 1μA; DC Withstanding Voltage: 0.1μA; Insulation Resistance: 0.1MΩ; Ground Resistance: 0.1mΩ; Conductivity Test: 0.01Ω)
Safety testing must consider functionality
The entire GPT-12000 series offers voltage rise and fall time settings and large capacitance testing capability (up to 47uF).
The GPT-12000 series not only provides a display of test results, but also provides a curve scanning function between the test voltage/current and the test results, allowing the user to analyze the voltage/current situation during the test process, which is especially convenient for finding insulation breakdown situations.
Statistical analysis, multistep testing, data saving and more are available.
Safety Engineer: 0512-666171777-672
18913132806
More video sharing content.
Goodwell Safety Test Knowledge Sharing https://v.youku.com/v_show/id_XNDYxNDE1OTUzNg==.html
GPT-12000 Safety Tester PPT Introduction https://v.youku.com/v_show/id_XNDYyMTc5MjU2MA==.html
GPT-12000 Series Capacitive Load Test Demo https://v.youku.com/v_show/id_XNDYyMTc5MjU0OA==.html
GPT-12000 USB flash drive auto storage function https://v.youku.com/v_show/id_XNDYyMjAyODQxNg==.html
GPT-12000 Rear Panel Introduction https://v.youku.com/v_show/id_XNDYyMjAyOTIxNg==.html
GPT-12000 Curve Scanning Function https://v.youku.com/v_show/id_XNDYyMjAyOTY4MA==.html
GPT-12000 Front Panel Introductionhttps://v.youku.com/v_show/id_XNDYyMjAyOTQ2MA==.html
GPT-12000 Data Statistical Analysis Functionhttps://v.youku.com/v_show/id_XNDYyMjAyOTkxMg==.html
GPT-12000 Operation Video https://v.youku.com/v_show/id_XNDg4NDY0MzUwOA==.html
Quick Selection
| model number | Key Features | Rear Panel Output | quantitative (science) | contiguity | standard interface |
| GPT-12004 | AC/DC/IR/GB | √ | 200VA | √ | USB/RS-232/I/O ports |
| GPT-12003 | AC/DC/IR | √ | 200VA | √ | USB/RS-232/I/O ports |
| GPT-12002 | AC/DC | √ | 200VA | √ | USB/RS-232/I/O ports |
| GPT-12001 | AC | √ | 200VA | √ | USB/RS-232/I/O ports |
Detailed specifications
This specification applies to the GPT-12000 energized for at least 30 minutes at 15℃~35℃.
| General Information | |
| demonstrate | 7" LCD |
| stockpile | 100 groups in manual mode; 100 groups in automatic mode |
| power supply | AC 100V~240V ± 10%, 50Hz/60Hz |
| Size & Weight | 380(W) x 148(H) x 454(D)mm /approx. 15kg |
| exchangesPressure resistance test | |||
| Output Voltage Range | 0.050kV~ 5.000kV | ||
| Output Voltage Resolution | 1V | ||
| Output Voltage Accuracy | ± (1% of setting +5V) (no load) | ||
| Maximum rated load (Table1) | 200VA (5kV/40mA) [GPT-12XXX] | ||
| Maximum rated current | 40mA [GPT-12XXX]
0.001mA~10mA(0.05k≤V≤0.5kV) 0.001mA~40mA(0.5kV<V≤5kV) |
||
| Output Voltage Waveform | simple harmonic vibration | ||
| frequency | 50 Hz / 60 Hz | ||
| Rate of change of voltage | ± (1% +5V)[Maximum rated load--no load] | ||
| Voltmeter Accuracy | ± (1% of reading+ 5 V) | ||
| Current measurement range | 0.001mA~40.00mA [GPT-12XXX] | ||
| Current Resolution | 1uA (1uA~9.999mA)
10uA(10.00mA~40.00mA) |
||
| Current measurement accuracy | ± (1.5% of reading+30uA) | ||
| Judgment accuracy | ± (3% of setting+30uA) | ||
| Upper/lower limit judgment function | Yes | ||
| ARC Detection | Yes | ||
| Rise time control function | Yes | ||
| RAMP TIME | 0.1~999.9S | ||
| Down time control function | Yes | ||
| RAMP DOWN Time | 0.0~999.9S | ||
| TIMER (test time)² | OFF, 0.3S~999.9S | ||
| GND | ON/OFF | ||
| WAIT TIME | 0.0~999.9S | ||
| 1, It takes at least 0.3 seconds to reach the set voltage of 50V/10mA. 2, The timer will turn off only when the upper current is set below 30 mA. |
|||
| direct current (D.C.)Withstanding Voltage Test (for GPT-12002/12003/12004) | |
| Output Voltage Range | 0.050kV~6.000kV¹ |
| Output Voltage Resolution | 1V |
| Output Voltage Accuracy | ±(1% of setting +5V) With no load |
| Maximum rated load | 50W (5kV/10mA) [GPT-12xxx] |
| Maximum rated current | 10mA [GPT-12XXX]
0.001mA~2mA(0.05kV£V£0.5kV) 0.001mA~10mA(0.5kV<V£6kV) |
| Voltmeter Accuracy | ± (1% of reading+ 5 V) |
| Voltage Resolution | ± (1% +5V)[Maximum rated load ->no load] |
| Current measurement range | 0.001mA-10.00mA |
| Current measurement resolution | 0.1uA
0.1uA (0.1uA~999.9uA) 1uA (1uA~9.999mA) 10uA (10.00mA) |
| Current measurement accuracy | ±(1.5% of reading+3uA) when I<1mA
±(1.5% of reading+30uA) when I≥1mA |
| Judgment accuracy | ± (3% of setting+30uA) |
| Upper/lower limit judgment function | Yes |
| ARC Detection | Yes |
| Rise time control function | Yes |
| RAMP TIME | 0.1~999.9S |
| Down time control function | Yes |
| RAMP DOWN Time | 0.0~999.9S |
| TIMER | OFF, 0.3S~999.9S |
| GND | ON/OFF |
| waiting time | 0.0~999.9S |
| Maximum capacitive load DC mode | 1uF |
| ¹ It takes at least 0.3 seconds to reach the set voltage of 50V/2mA. | |
| Insulation resistance test (for 12003/12004) | |||
| output voltage | 50V-1200V | ||
| Output Voltage Resolution | 50V | ||
| Output Voltage Accuracy | ±(1% of setting +5V) with no load | ||
| Resistance Measurement Range | 0.1MΩ~50GΩ | ||
| Measurement voltage / Measurement range / Measurement accuracy | |||
| 50V≤V≤450V
|
0.1MΩ~1MΩ | 5% of reading + 3 count | |
| 1MΩ~50MΩ | 5% of reading + 1 count | ||
| 51MΩ~2GΩ | 10% of reading + 1 count | ||
| 500V≤V≤1200V
|
0.1MΩ~1MΩ | 5% of reading + 3 count | |
| 1MΩ~500MΩ | 5% of reading + 1 count | ||
| 501MΩ~9.999GΩ | 10% of reading + 1 count | ||
| 10G~50GΩ | 20% of reading + 1 count¹ | ||
| test voltage | Display Range | ||
| 50V≤V≤100V | 000.1MΩ~10.00GΩ | ||
| 150V≤V≤450V | 000.1MΩ~20.00GΩ | ||
| 500V≤V≤1200V | 000.1MΩ~50.00GΩ | ||
| Voltage regulation | ± (1% +5V) [Maximum rated load ->no load | ||
| Voltmeter Accuracy | ±(1% of reading +5V) | ||
| short-circuit current | 10mA max. | ||
| Output Impedance | 2kΩ | ||
| Upper/lower limit judgment function | Yes | ||
| Rise time control function | Yes | ||
| RAMP UP | 0.1~999.9S | ||
| Down time control function | Yes | ||
| RAMP DOWN (downtime) | 0.0~999.9S | ||
| waiting time | 0.0~999.9S | ||
| TIMER | 0.3S~999.9S2 | ||
| GND | ON/OFF | ||
| Note: When the insulation resistance ground mode is turned on, the GND OFFSET action needs to be performed.
1When the insulation resistance grounding method is ON, a maximum of 30 Gohm can be guaranteed. |
|||
| 2 When the insulation resistance grounding mode is on, the test time starts from 0.5 seconds. | |||
| Ground impedance test (for GPT-12004) | |
| Output Current Range | 3.00A~32.00A |
| Output current accuracy | ±(1% of setting+0.2A) when 3A≤I≤8A |
| ±(1% of setting+0.05A) 8A < I ≤ 32A | |
| Output current resolution | 0.01A |
| test voltage | Approximately max. 8VAC (open-circuit) |
| frequency | 50Hz/60Hz selectable |
| Resistance Meter Measuring Range | 1mΩ ~ 650mΩ |
| Resistance Meter Measurement Resolution | 0.1mΩ |
| Resistance Meter Measurement Accuracy | ±(1% of reading+2mΩ) |
| Resistance Meter Judgment Accuracy | ±(1% of setting+2mΩ) |
| Upper and lower limit judgment function | Yes |
| TIMER | 0.3S~999.9S |
| GND | ON/OFF |
| conductionbeta (software) | ||
| Output Current | 100mA(DC) | |
| Resistance Meter Measuring Range | 0.10Ω~70.00Ω | |
| Resistance Meter Measurement Resolution | 0.01Ω | |
| Resistance Meter Measurement Accuracy | ±(10% of reading+2Ω) | |
| Resistance Meter Judgment Accuracy | ±(10% of setting+2Ω) | |
| Upper and lower limit judgment function | Yes | |
| TIMER | 0.3S~999.9S | |
| connector | ||
| REMOTE (Remote Terminal) | Yes | |
| SIGNAL IO | Yes | |
| RS-232 | Yes | |
| USB (Device) | Yes (USB 2.0) | |
| Rear Output | Yes | |
| USB (Host) for data output port | Yes (USB 2.0) | |
| GPIB | Yes (optional) | |
Standard Accessories
Quick Operation Manual x 1,
CD x1.
Power cord x 1,
Interlock key x 1,
Programmable Terminal Hookup GHT-119 x 1,
Test Lead GHT-115 x 1 for GPT-12003/12002/12001
Test Lead GHT-115 x 1, GTL-215 x 1 for GPT-12004
optional
Opt.1 GPIB card
Optional Accessories
GHT-113 High Pressure Test Gun
GHT-205 High Pressure Test Probe
GTL-232 RS232C Data Cable, 9-pin Female to 9-pin, null Modem for Computer
GTL-246 USB cable, A-B type, approx. 1.2m
GTL-248 GPIB cable, approx. 2m
GPT-12004 AC/DC/IR/GB Electrical Safety Analyzer
GPT-12003 AC/DC/IR Electrical Safety Analyzer
GPT-12002 AC/DC Electrical Safety Analyzer
GPT-12001 AC Electrical Safety Analyzer
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.