DP6000 Electrical Specifications
Model No. | DP6150 | DP6350 | DP6700 | ||||
Bandwidth (-3dB) | 70MHz | ||||||
rising time | ≤5ns | ||||||
accurate | ±2% | ||||||
Range selection (attenuation ratio) | 50X/500X | 100X/1000X | 100X/1000X | ||||
Maximum differential measurement voltage
(DC + Peak AC) |
50X | ±150V | 100X | ±350V | 100X | ±700V | |
500X | ±1500V | 1000X | ±3500V | 1000X | ±7000V | ||
Common mode voltage (DC + Peak AC) | ±1500V | ±3500V | ±7000V | ||||
Maximum Differential Mode Voltage VS Frequency Curve | Refer to Figure 1 | Refer to Figure 2 | Refer to Figure 3 | ||||
Maximum input voltage to ground (Vrms) | 600V CATIII
1000V CATII |
600V CATIII
1000V CATII |
1000V CATIII
2300V CATI |
||||
Input Impedance | single-ended to ground (computing) | 5MΩ | 5MΩ | 20MΩ | |||
Two inputs | 10MΩ | 10MΩ | 40MΩ | ||||
Input Capacitance | single-ended to ground (computing) | <4pF | <4pF | <5pF | |||
Two inputs | <2pF | <2pF | <2.5pF | ||||
CMRR | DC | >80dB | >80dB | >80dB | |||
100kHz | >60dB | >60dB | >60dB | ||||
1MHz | >50dB | >50dB | >50dB | ||||
Noise (Vrms) | 50X | <50mV | 100X | <100mV | 100X | <220mV | |
500X | <300mV | 1000X | <600mV | 1000X | <1.2V | ||
Overload indication voltage threshold | 50X | ≥150V | 100X | ≥350V | 100X | ≥700V | |
500X | ≥1500V | 1000X | ≥3500V | 1000X | ≥7000V | ||
latency | Probe host | 50X | 9ns | 100X | 9.3ns | 100X | 9.3ns |
500X | 7.5ns | 1000X | 7.4ns | 1000X | 7.2ns | ||
BNC cable (1m) | 5ns | ||||||
Bandwidth Limit (5MHz) | ≥-3dB@5MHz | ||||||
Overload indicator (red) | there are | ||||||
Overload alarm sound | Yes (optionally off) | ||||||
Autosave Function | there are | ||||||
Adjustable bias function | Yes (enter test mode to adjust) | ||||||
Terminal Load Requirements | ≥100kΩ | ||||||
power supply | USB 5V/2A Adapter | ||||||
Safety meets standards | EN61010-1: 2010 | ||||||
EMC Compliance | en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013 |
DP6000A Electrical Specifications
Model No. | DP6070A | DP6150A | DP6350A | DP6700A | |||||
Bandwidth (-3dB) | 100MHz | ||||||||
rising time | ≤3.5ns | ||||||||
accurate | ±2% | ||||||||
Range selection (attenuation ratio) | 10X/100X | 50X/500X | 100X/1000X | 100X/1000X | |||||
Maximum differential measurement voltage
(DC + Peak AC) |
10X | ±70V | 50X | ±150V | 100X | ±350V | 100X | ±700V | |
100X | ±700V | 500X | ±1500V | 1000X | ±3500V | 1000X | ±7000V | ||
Common mode voltage (DC + Peak AC) | ±700V | ±1500V | ±3500V | ±7000V | |||||
Maximum Differential Mode Voltage VS Frequency Curve | Refer to Figure 1 | Refer to Figure 2 | Refer to Figure 3 | Refer to Figure 4 | |||||
Maximum input voltage to ground (Vrms) | 450V CATII
600V CATI |
600V CATIII
1000V CATII |
600V CATIII
1000V CATII |
1000V CATIII
2300V CATI |
|||||
Input Impedance | single-ended to ground (computing) | 2.5MΩ | 5MΩ | 5MΩ | 20MΩ | ||||
Two inputs | 5MΩ | 10MΩ | 10MΩ | 40MΩ | |||||
Input Capacitance | single-ended to ground (computing) | <4pF | <4pF | <4pF | <5pF | ||||
Two inputs | <2pF | <2pF | <2pF | <2.5pF | |||||
CMRR | DC | >80dB | >80dB | >80dB | >80dB | ||||
100kHz | >60dB | >60dB | >60dB | >60dB | |||||
1MHz | >50dB | >50dB | >50dB | >50dB | |||||
Noise (Vrms) | 10X | <25mV | 50X | <50mV | 100X | <100mV | 100X | <220mV | |
100X | <120mV | 500X | <300mV | 1000X | <600mV | 1000X | <1.2V | ||
Overload indication voltage threshold | 10X | ≥70V | 50X | ≥150V | 100X | ≥350V | 100X | ≥700V | |
100X | ≥700V | 500X | ≥1500V | 1000X | ≥3500V | 1000X | ≥7000V | ||
latency | Probe host | 10X | 8.7ns | 50X | 8.5ns | 100X | 8.2ns | 100X | 8.9ns |
100X | 8.1ns | 500X | 7.5ns | 1000X | 7.4ns | 1000X | 6.6ns | ||
BNC cable (1m) | 5ns | ||||||||
Bandwidth Limit (5MHz) | ≥-3dB@5MHz | ||||||||
Overload indicator (red) | there are | ||||||||
Overload alarm sound | Yes (optionally off) | ||||||||
Autosave Function | there are | ||||||||
Adjustable bias function | Yes (enter test mode to adjust) | ||||||||
Terminal Load Requirements | ≥100kΩ | ||||||||
power supply | USB 5V/2A Adapter | ||||||||
Safety meets standards | EN61010-1: 2010 | ||||||||
EMC Compliance | en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013 |
DP6000B Electrical Specifications
Model No. | DP6070B | DP6150B | DP6350B | DP6700B | |||||
Bandwidth (-3dB) | 300MHz | ||||||||
rising time | ≤1.16ns | ||||||||
accurate | ±2% | ||||||||
Range selection (attenuation ratio) | 20X/200X | 50X/500X | 100X/1000X | 200X/2000X | |||||
Maximum differential measurement voltage
(DC + Peak AC) |
20X | ±70V | 50X | ±150V | 100X | ±350V | 200X | ±700V | |
200X | ±700V | 500X | ±1500V | 1000X | ±3500V | 2000X | ±7000V | ||
Common mode voltage (DC + Peak AC) | ±700V | ±1500V | ±3500V | ±7000V | |||||
Maximum Differential Mode Voltage VS Frequency Curve | Refer to Figure 1 | Refer to Figure 2 | Refer to Figure 3 | Refer to Figure 4 | |||||
Maximum input voltage to ground (Vrms) | 450V CATII
600V CATI |
600V CATIII
1000V CATII |
600V CATIII
1000V CATII |
1000V CATIII
2300V CATI |
|||||
Input Impedance | single-ended to ground (computing) | 2.5MΩ | 5MΩ | 5MΩ | 20MΩ | ||||
Two inputs | 5MΩ | 10MΩ | 10MΩ | 40MΩ | |||||
Input Capacitance | single-ended to ground (computing) | <4pF | <4pF | <4pF | <5pF | ||||
Two inputs | <2pF | <2pF | <2pF | <2.5pF | |||||
CMRR | DC | >80dB | >80dB | >80dB | >80dB | ||||
100kHz | >60dB | >60dB | >60dB | >60dB | |||||
1MHz | >50dB | >50dB | >50dB | >50dB | |||||
Noise (Vrms) | 20X | <90mV | 50X | <115mV | 100X | <350mV | 200X | <550mV | |
200X | <120mV | 500X | <180mV | 1000X | <550mV | 2000X | <1V | ||
Overload indication voltage threshold | 20X | ≥70V | 50X | ≥150V | 100X | ≥350V | 200X | ≥700V | |
200X | ≥700V | 500X | ≥1500V | 1000X | ≥3500V | 2000X | ≥7000V | ||
latency | Probe host | 20X | 5.6ns | 50X | 5.5ns | 100X | 5.2ns | 200X | 5.1ns |
200X | 4.5ns | 500X | 4.5ns | 1000X | 4.2ns | 2000X | 4.2ns | ||
BNC cable (1m) | 5ns | ||||||||
Bandwidth Limit (5MHz) | ≥-3dB@5MHz | ||||||||
Overload indicator (red) | there are | ||||||||
Overload alarm sound | Yes (optionally off) | ||||||||
Autosave Function | there are | ||||||||
Adjustable bias function | Yes (enter test mode to adjust) | ||||||||
Terminal Load Requirements | ≥100kΩ | ||||||||
power supply | USB 5V/2A Adapter | ||||||||
Safety meets standards | EN61010-1: 2010 | ||||||||
EMC Compliance | en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013 |
DP6000D Electrical Specifications
Model No. | DP6070D | DP6150D | DP6350D | DP6700D | |||||
Bandwidth (-3dB) | 500MHz | ||||||||
rising time | ≤700ps | ||||||||
accurate | ±2% | ||||||||
Range selection (attenuation ratio) | 20X/200X | 100X/1000X | 200X/2000X | 200X/2000X | |||||
Maximum differential measurement voltage
(DC + Peak AC) |
20X | ±70V | 100X | ±150V | 200X | ±350V | 200X | ±700V | |
200X | ±700V | 1000X | ±1500V | 2000X | ±3500V | 2000X | ±7000V | ||
Common mode voltage (DC + Peak AC) | ±700V | ±1500V | ±3500V | ±7000V | |||||
Maximum Differential Mode Voltage VS Frequency Curve | Refer to Figure 1 | Refer to Figure 2 | Refer to Figure 3 | Refer to Figure 4 | |||||
Maximum input voltage to ground (Vrms) | 450V CATII
600V CATI |
600V CATIII
1000V CATII |
600V CATIII
1000V CATII |
1000V CATIII
2300V CATI |
|||||
Input Impedance | single-ended to ground (computing) | 2.5MΩ | 5MΩ | 5MΩ | 20MΩ | ||||
Two inputs | 5MΩ | 10MΩ | 10MΩ | 40MΩ | |||||
Input Capacitance | single-ended to ground (computing) | <4pF | <4pF | <4pF | <5pF | ||||
Two inputs | <2pF | <2pF | <2pF | <2.5pF | |||||
CMRR | DC | >80dB | >80dB | >80dB | >80dB | ||||
100kHz | >60dB | >60dB | >60dB | >60dB | |||||
1MHz | >50dB | >50dB | >50dB | >50dB | |||||
Noise (Vrms) | 20X | <90mV | 100X | <200mV | 200X | <350mV | 200X | <625mV | |
200X | <130mV | 1000X | <420mV | 2000X | <730mV | 2000X | <1V | ||
Overload indication voltage threshold | 20X | ≥70V | 100X | ≥150V | 200X | ≥350V | 200X | ≥700V | |
200X | ≥700V | 1000X | ≥1500V | 2000X | ≥3500V | 2000X | ≥7000V | ||
latency | Probe host | 20X | 5.6ns | 100X | 5.5ns | 200X | 5.3ns | 200X | 5.6ns |
200X | 4.9ns | 1000X | 4.5ns | 2000X | 4.5ns | 2000X | 4.6ns | ||
BNC cable (1m) | 5ns | ||||||||
Bandwidth Limit (5MHz) | ≥-3dB@5MHz | ||||||||
Overload indicator (red) | there are | ||||||||
Overload alarm sound | Yes (optionally off) | ||||||||
Autosave Function | there are | ||||||||
Adjustable bias function | Yes (enter test mode to adjust) | ||||||||
Terminal Load Requirements | 50Ω | ||||||||
power supply | USB 5V/2A Adapter | ||||||||
Safety meets standards | EN61010-1: 2010 | ||||||||
EMC Compliance | en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013 |