Product Overview: Fluke 117C Non-Contact Voltage Measurement Multimeter
Designed for electrical technicians and manufactured by Fluke.
Compact True RMS Meter for Commercial Applications The Fluke 117C is a meter for use in demanding environments such as commercial buildings, hospitals, and schools.The Fluke 117C includes integrated non-contact voltage detection to help make measurements faster.
Also available are the Fluke 114 Electrical Measurement Multimeter, the Fluke 115C Multimeter, and the Fluke 116C HVAC Multimeter with temperature and microamp current measurement.
Product Specifications: Fluke 117C Non-Contact Voltage Measurement Multimeter
technical specification | ||
Maximum voltage between any terminal and ground | 600 V | |
overvoltage protection | 6 kV peak according to IEC 61010-1 600 VCAT III, pollution class 2 | |
A Input fuse | 11 A, 1000 V Fast-Acting Fuse (Fluke PN 803293) | |
monitor | Numbers: 6000 counts, 4 updates per second | |
histogram | 33 segments, 32 updates per second | |
operating temperature | -10 °C to +50 °C | |
storage temperature | -40 °C to +60 °C | |
Battery Type | 9 V alkaline battery, NEDA 1604A / IEC 6LR61 | |
Battery life | Typically 400 hours without backlight | |
Accuracy Specifications | ||
DC millivolt | Range/Resolution | 600.0 mV / 0.1 mV |
accurate | ± ([% of reading] + [number of counts]): 0.5% + 2 | |
dc voltage | Range/Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
accurate | ± ([% of reading] + [number of counts]): 0.5% + 2 | |
Automatic. Volt. | Range/Resolution | 600.0 V / 0.1 V |
accurate | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
AC voltage (mV)¹ true RMS value | Range/Resolution | 600.0 mV / 0.1 mV |
accurate | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC Voltage¹ True RMS | Range/Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
accurate | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
intermittence | Range/Resolution | 600 Ω / 1 Ω |
accurate | Buzzer 250 Ω when off; detected 500 μs or more for open or short circuits. |
|
ohm (loanword) | Range/Resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
accurate | 0.9% + 1 | |
Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
accurate | 5% + 2 | |
Diode Testing | Range/Resolution | 2.00 V / 0.001 V |
accurate | 0.9% + 2 | |
capacitors | Range/Resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
accurate | 1.9% + 2 | |
Range/Resolution | > 1000 μF | |
accurate | 5% + 20% | |
Lo-Z Capacitor | range (of scales or measuring equipment) | 1 nF to 500 μF |
accurate | 10% + 2 µδΠΝ | |
AC Ampere True RMS (45 Hz to 500 Hz) | Range/Resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
accurate | 1.5% + 3 20 A continuous overload up to 30 seconds |
|
DC amperage | Range/Resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
accurate | 1.0% + 3 20 A continuous overload up to 30 seconds |
|
Hz (voltage or current input)² | Range/Resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
accurate | 0.1% + 2 | |
1. All AC voltage ranges (except Auto-V/LoZ) are specified as 1% to 100% of the range. the starting range of Auto-V/LoZ is specified as 0.0 V. The starting range of Auto-V/LoZ is specified as 0.0 V. The starting range of Auto-V/LoZ is specified as 0.0 V. 2. Temperature error (accuracy) does not include thermocouple probe error. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage and DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature range/resolution: -40 °F to 752 °F / 0.2 °F. |
||
Mechanical and general specifications | ||
sizes | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
weights | 550 g | |
warranty period | 3 years |
Model: Fluke 117C Non-Contact Voltage Measurement Multimeter
Fluke 117
Electrician's multi-meter with non-contact voltage detection function
This model includes the following components:
- sleeve
- user manual