Fluke 117C Non-Contact Voltage Measurement Multimeter
Fluke 117C Non-Contact Voltage Measurement Multimeter
Fluke 117C Non-Contact Voltage Measurement Multimeter
Fluke 117C Non-Contact Voltage Measurement Multimeter
Fluke 117C Non-Contact Voltage Measurement Multimeter
Fluke 117C Non-Contact Voltage Measurement Multimeter

Fluke 117C Non-Contact Voltage Measurement Multimeter

Main characteristics

  • Features VoltAlert™ technology for non-contact voltage detection
  • AutoVolt Automatic DC/AC Voltage Selection
  • LoZ function: low input impedance prevents false readings due to spurious voltages
  • White LED backlight illumination Effective reading even in low light locations
  • True RMS for accurate measurement of non-linear loads
  • Measures 20 A (30 seconds instantaneous; 10 A continuous)
  • Resistance, continuity, frequency and capacitance measurements
  • Provides min/max/average values to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Measurements can be taken hands-free using the optional magnetic meter suspension strap (ToolPak™).
  • Safety class CAT III 600 V

SKU:Fluke 117C Category. Brand.

Inquire about this product

Product Overview: Fluke 117C Non-Contact Voltage Measurement Multimeter

Designed for electrical technicians and manufactured by Fluke.

Compact True RMS Meter for Commercial Applications The Fluke 117C is a meter for use in demanding environments such as commercial buildings, hospitals, and schools.The Fluke 117C includes integrated non-contact voltage detection to help make measurements faster.

Also available are the Fluke 114 Electrical Measurement Multimeter, the Fluke 115C Multimeter, and the Fluke 116C HVAC Multimeter with temperature and microamp current measurement.

Product Specifications: Fluke 117C Non-Contact Voltage Measurement Multimeter

technical specification
Maximum voltage between any terminal and ground 600 V
overvoltage protection 6 kV peak according to IEC 61010-1 600 VCAT III, pollution class 2
A Input fuse 11 A, 1000 V Fast-Acting Fuse (Fluke PN 803293)
monitor Numbers: 6000 counts, 4 updates per second
histogram 33 segments, 32 updates per second
operating temperature -10 °C to +50 °C
storage temperature -40 °C to +60 °C
Battery Type 9 V alkaline battery, NEDA 1604A / IEC 6LR61
Battery life Typically 400 hours without backlight
Accuracy Specifications
DC millivolt Range/Resolution 600.0 mV / 0.1 mV
accurate ± ([% of reading] + [number of counts]): 0.5% + 2
dc voltage Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
accurate ± ([% of reading] + [number of counts]): 0.5% + 2
Automatic. Volt. Range/Resolution 600.0 V / 0.1 V
accurate 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC voltage (mV)¹ true RMS value Range/Resolution 600.0 mV / 0.1 mV
accurate 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC Voltage¹ True RMS Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
accurate 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
intermittence Range/Resolution 600 Ω / 1 Ω
accurate Buzzer 250 Ω when off; detected
500 μs or more for open or short circuits.
ohm (loanword) Range/Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
accurate 0.9% + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
accurate 5% + 2
Diode Testing Range/Resolution 2.00 V / 0.001 V
accurate 0.9% + 2
capacitors Range/Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
accurate 1.9% + 2
Range/Resolution > 1000 μF
accurate 5% + 20%
Lo-Z Capacitor range (of scales or measuring equipment) 1 nF to 500 μF
accurate 10% + 2 µδΠΝ
AC Ampere True RMS (45 Hz to 500 Hz) Range/Resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
accurate 1.5% + 3
20 A continuous overload up to 30 seconds
DC amperage Range/Resolution 6.000 A / 0.001 A 10.00 A / 0.01 A
accurate 1.0% + 3
20 A continuous overload up to 30 seconds
Hz (voltage or current input)² Range/Resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
accurate 0.1% + 2
1. All AC voltage ranges (except Auto-V/LoZ) are specified as 1% to 100% of the range. the starting range of Auto-V/LoZ is specified as 0.0 V. The starting range of Auto-V/LoZ is specified as 0.0 V. The starting range of Auto-V/LoZ is specified as 0.0 V.
2. Temperature error (accuracy) does not include thermocouple probe error.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage and DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature range/resolution: -40 °F to 752 °F / 0.2 °F.
Mechanical and general specifications
sizes 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
weights 550 g
warranty period 3 years

Model: Fluke 117C Non-Contact Voltage Measurement Multimeter

Fluke 117

Electrician's multi-meter with non-contact voltage detection function

This model includes the following components:

  • sleeve
  • user manual

F117C Technical Specification [Please login to download and view]

115C-117C Product Manual [Please login to download and view]

Expand More
Fluke 117C Non-Contact Voltage Measurement MultimeterFluke 117C Non-Contact Voltage Measurement Multimeter

Click to enquire

Product consultation and purchase:18218718851

I already understand