Product Overview: Fluke 110 True RMS Digital Multimeter
Compact True RMS meter for precise electrical installations and diagnostics
The Fluke 110 is a multifunction multimeter for electrical measurement and diagnostics. It serves as a reliable electrical diagnostic and maintenance device for home and business use.110 It is also suitable for professional applications requiring true RMS accuracy.
Main Product Features
- Accurately measures true RMS AC voltage for non-linear signals
- Large white LED backlight lets you work in poorly lit areas
- Resistance and Intermittency
- Minimum/maximum/average values, recording signal fluctuations
- Safety class CAT III 600 V
Product Specifications: Fluke 110 True RMS Digital Multimeter
Accuracy is good for one year after calibration at operating temperatures from 18 °C to 28 °C and relative humidity from 0 % to 90 %. Accuracy specifications are shown as the following values: ± ([% of reading] + [count])
| General technical indicators | |
|---|---|
| Maximum voltage (between any terminal and ground) | 600V |
| safety | IEC 61010-1, pollution class 2 IEC 61010-2-033, CAT III 600 V |
| monitor | Digital: 6,000 counts, 4 updates per second |
| bar chart | 33 segments, 32 updates per second |
| temp (of a machine) operate leave in sb's care |
-10 °C to + 50 °C -40 °C to + 60 °C |
| batteries | 9 V alkaline battery, IEC 6LR61 |
| Battery life | Typically 400 hours without backlight |
| accurate | |||
|---|---|---|---|
| surveying | range (of scales or measuring equipment) | resolution (of a photo) | Accuracy ± ([% of readings] + [counts]) |
| DC voltage (mV) | 600.0 mV | 0.1 mV | 0.5% + 2 |
| dc voltage | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5% + 2 |
| accurate | |||
|---|---|---|---|
| surveying | range (of scales or measuring equipment) | resolution (of a photo) | Accuracy ± ([% of readings] + [counts]) |
| AC millivolt1 True RMS | 600.0 mV | 0.1 mV | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| AC Volts1 True RMS | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| intermittence | 600 Ω | 1 Ω | Buzzer 250 Ω when off; detects open or short circuits for 500 μs or more. |
| ohm (loanword) | 600.0 Ω | 0.1 Ω | 0.9 % + 2 |
| 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ |
0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ |
0.9 % + 1 | |
| 40.00 MΩ | 0.01 MΩ | 5 % + 2 | |
1All AC voltage ranges have been specified as ranges from 1 % to 100%. Because no inputs are specified for ranges below 1 %, it is normal for this and other true RMS meters to display non-zero readings when the test leads are disconnected or shorted from the circuit. For voltage, the crest factor is ≤ 3 at 4000 counts and decreases linearly to 1.5 at full scale. ac volts are ac-coupled.
Model: Fluke 110 True RMS Digital Multimeter
Fluke 110 True RMS Digital Multimeter
Included:
- Fluke 110 True RMS Multimeter
- TL75 Hard Point™ Test Lead Set with Protective Cover
- 9 V battery (installed)
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.