Product Overview: Fluke 324 True RMS Clamp Meter
The Fluke 324 True RMS Clamp Meter for Commercial and Residential Electricians is a reliable, rugged troubleshooting and troubleshooting tool featuring True RMS measurement, a slim design for easy transportation and use, and a wide display for efficient troubleshooting and troubleshooting. The addition of temperature and capacitance functions meets all the needs of HVAC technicians.
Safe and accurate diagnosis and troubleshooting
Safe and accurate diagnosis and troubleshooting
- CAT III 600 V, CAT IV 300 V safety rating
- Provides true RMS AC voltage and current measurements for accurate measurement of non-linear signals
- Measures up to 400 A AC current
- Measurable 600V AC/DC Voltage
- Measurable 4kΩ resistance, on-off detection ≤ 30Ω
- Measures temperatures in the range of -10°C to 400°C
- Measures up to 1000μF capacitance
- Backlight and hold function to capture the reading shown on the display
- Comes with a two-year warranty and standard soft carry case
Fluke 320 Series Clamp Meter for Electrical Troubleshooting and Troubleshooting
| Fluke 323 True RMS Clamp Meter | Fluke 324 True RMS Clamp Meter | Fluke 325 True RMS Clamp Meter | |
| alternating current (electricity) | 400A | 40A/400A | 40A/400A |
| DC A | 40A/400A | ||
| AC/DC voltage | 600V | 600V | 600V |
| resistive | 400Ω/4kΩ | 400Ω/4kΩ | 400Ω/4kΩ/40kΩ |
| intermittence | ≤ 70Ω | ≤ 30Ω | ≤ 30Ω |
| capacitors | 100μF/1000μF | 100μF/1000μF | |
| temp | -10°C to 400°C | -10°C to 400°C | |
| do sth. with one's back to the light | there are | there are | |
| frequency | 5Hz to 500Hz | ||
| Min/Max | there are |
Standard:
- Fluke 324 True RMS Clamp Meter
- TL75 Test Leads
- Type K thermocouple
- 2 AAA batteries (installed)
- soft pallet
Product Specifications: Fluke 324 True RMS Clamp Meter
| Technical indicators | ||
| alternating current (electricity) | range (of scales or measuring equipment) | 40.00 A / 400.0 A |
| accuracy | 1.5% ± 5 words (45 Hz to 400 Hz) Note: Increase by 2% @ position sensitivity |
|
| direct current | range (of scales or measuring equipment) | - |
| accuracy | - | |
| alternating current | range (of scales or measuring equipment) | 600.0 V |
| accurate | 1.5% ± 5 words | |
| dc voltage | range (of scales or measuring equipment) | 600.0 V |
| accurate | 1.0% ± 5 words | |
| resistive | range (of scales or measuring equipment) | 400.0 Ω/ 4000 Ω |
| accuracy | 1.0% ± 5 words | |
| intermittence | ≤ 30 Ω | |
| capacitors | 0 to 100.0 μF / 100 μF to 1000 μF | |
| frequency | - | |
| AC response | true rms | |
| do sth. with one's back to the light | there are | |
| Data retention | there are | |
| contact temperature | -10.0°C to 400.0°C (14.0°F to 752.0°F) | |
| Min/Max | - | |
| sizes | H x W x D (mm) | 207 x 75 x 34 |
| Maximum wire diameter | 30 mm (600 MCM) | |
| weights | 208 g | |
| rating | CAT III 600 V CAT IV 300 V |
|
| Low Pass Filter Parameters | Built-in, 800Hz | |
| warranty | 2 years | |
Model: Fluke 324 True RMS Clamp Meter
Fluke 324
Fluke 324 True RMS Clamp Meter
- Fluke 324 True RMS Clamp Meter
- TL75 Test Leads
- Type K thermocouple
- 2 AAA batteries (installed)
- soft pallet
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.