Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")

Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")

¥999,999.00

Main characteristics

  • Insulation testing from 0.01 MΩ to 10 GΩ
  • Remote test probes to make repetitive testing or testing of hard-to-reach DUTs easier
  • Insulation test voltages: 50 V, 100 V, 250 V, 500 V and 1000 V for a wide range of applications
  • Pass/fail (compare) function for easy and convenient repeatability testing
  • Save/recall function with 19 storage units saves time and labor
  • AC/DC voltage: 0.1 V to 600 V
  • Resistance: 0.01 Ω to 20.00 KΩ
  • Auto shut-off function to save battery power
  • CAT IV 600 V measured safety level for increased protection of personnel
  • Included Accessories: Test Leads, Test Probes, Remote Meter Pen, Alligator Clips
  • 5 Years Warranty

SKU:Fluke 1508 IND Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")

Fluke 1508 IND
The 1508 IND Insulation Resistance Tester is tailor-made for industrial enterprise users, upgrading again on the original guarantee of accuracy, durability, safety and ease of use, extending the warranty period to 5 years, and upgrading the test accessories with a large crocodile clip set to measure more target scenarios.

Product Specification: Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")

Product Specifications: Fluke 1508 IND Insulation Resistance Tester (Digital "Shaking Meter")

AC/DC voltage measurement
accurate realm 600.0 V
resolution (of a photo) 0.1 V
50 Hz to 400 Hz ± (% reading + digits) ± (2 % + 3)
Input Impedance 3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced) > 60 dB at DC, 50 or 60 Hz
overload protection 600 V rms or DC
Ground Wire Resistance Measurement
Range/Resolution 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1 Ω
20.00 kΩ 0.01 kΩ
accurate ± (1.5 % + 3)
overload protection 2 V RMS or DC
Open Circuit Test Voltage > 4.0 V, < 8 V
short-circuit current > 200.0 mA
Insulation specifications
Measurement range 0.01 MΩ to 10 GΩ
test voltage 50 V, 100 V, 250 V, 500 V, 1000 V
Test Voltage Accuracy + 20 %, - 0 %
Short circuit test current 1 mA, nominal
Automatic discharge Discharge time <0.5 s when C = 1 µF or less
Energized circuit detection function If a voltage greater than 30 V is detected prior to test initialization, the test is disabled.
Maximum capacitive load Operates with loads up to 1 µF.
General technical parameters
Maximum voltage applied to any terminal 600 V AC RMS or DC
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
temperature coefficient 0.05 × (given accuracy) / °C for temperatures 28 °C ( 82 °F)
relative humidity 0 % to 95 % at 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % at 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % at 40 °C to 55 °C (104 °F to 131 °F)
vibration Random, 2 g, 5-500 Hz, meets the requirements of MIL-PRF-28800F, Class 2 instrumentation
impact resistance 1 m drop according to IEC 61010-1, 2nd edition (1 m drop test, 6 sides, oak floor)
electromagnetic compatibility Accuracy = given accuracy in RF fields of 3 V/M (EN 61326-1:1997)
surety Meets the requirements of ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No. 1010.1 and IEC/EN 61010-1 2nd edition for CAT IV 600 V equipment.
accreditation CSA, according to standard CSA/CAN C22.2 No. 1010.1; TUV, according to standard IEC/EN 61010-1, 2nd ed.
batteries 4 AA type batteries ((NEDA 15A or IEC LR6))
Battery life For insulation tests. At least 1000 insulation tests can be performed at room temperature with new batteries. Tests refer to standard tests: 1000 V to 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
For resistance measurements. At least 2500 ground resistance measurements can be made at room temperature with a fresh battery. Tests refer to the standard test: 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
sizes 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
weights 550 g (1.2 lb)
IP rating IP40
altitude (of a machine) operate 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-working (storage) 12,000 m
overload capacity 110 % Scope

Model: Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")

Fluke 1508 IND

embody

  • Fluke 1508 Insulation Resistance Tester Mainframe
  • TLL224 Test Leads
  • TP74 Test Probe
  • TP165X Remote Meter Pen
  • Large Crocodile Clip
  • user manual

Note: The Fluke 1508 IND is an accessory and warranty upgrade for the Fluke 1508.

F1508-IND technical parameters [please login to download and view].

Expand More
Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")Fluke 1508 IND Insulation Resistance Tester (Digital "Shake Meter")
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand