Product Overview: TiS75+ Thermal Imaging Camera
Precision upgraded and reconstructed for clarity
Compared to the original model (TiS75), the new product has 44%* more pixels, which will provide users with clearer and more accurate measurement results. And the thermal sensitivity has been upgraded simultaneously, enabling detection of even smaller temperature changes.
*384 x 288 pixels (TiS75+) 320 x 240 pixels (TiS75)
Focus-free + manual focus for both near and far
For quick scans or novices unfamiliar with thermal imaging, simply turn the focus ring to the fixed focus position to use the focus-free mode to capture images at 1m or more away from the target and ensure accurate focus every time.
For experienced engineers, the image can be adjusted according to the distance of the object to be measured using the manual focus mode to obtain a high quality and clear thermal image, or to realize a close and clear observation of small targets, such as the heat of circuit board components, LED chips and so on.
Smart Data, Simplicity and Complexity
The integrated intelligence of the TiS55+ and TiS75+ means that users can completely throw away their notepads and attach all the information they need to their saved heat maps and have them automatically organized and filed by the machine, saving valuable time spent analyzing heat maps and diagnosing problems:
- Voice Annotation - Utilizing a Bluetooth headset (optional), up to 60 seconds of voice can be recorded per image, accurately identifying what you see in the field in real time
- IR-PhotoNotes - take equipment numbers and other field photos as a reference when viewing heat maps on a computer
- Asset Tagging Device Intelligent Recognition Technology - Scan the QR code on the device and start taking heatmaps, which will be automatically saved in a folder under the current device name, eliminating the need to manually organize them. All data can be shared and analyzed in the cloud.
Meanwhile, the newly upgraded 3.5-inch touch screen is more suitable for modern engineers' habits, with a tap to complete the setup and a swipe to switch between IR/visible light.
Data Streaming Function, Measure and Analyze
Data streaming function can help users in the test can be through the data cable with temperature data real-time data transfer data to the computer, can help users instantly in the PC terminal to complete more complex analysis test work.
27Hz frame rate model for recording high-speed moments
In addition to the 9Hz frame rate model, the TiS75+ is also available in an optional 27Hz frame rate model, ideal for observing fast-moving or rapidly changing temperature targets, so say goodbye to dragging shadows.
Product Specifications: TiS75+ Thermal Imaging Camera
| core functionality | TiS75+ |
| Infrared resolution | 384 x 288 (110,592 pixels) |
| IFOV | 1.91 mRad |
| field of view | 42° x 30° |
| focusing system | Manual focus, fixed focal length (focus position positioned at 1 meter) |
| wireless connection | Yes, connects to PC, iPhone® and iPad® (iOS 4s and newer), Android™ 4.3 and newer, as well as WiFi and LAN (where provided) |
| Compatible with Fluke Connect Applications | Yes*, connecting the camera to a smartphone automatically captures an image and uploads it to the Fluke Connect app for saving and sharing |
| Fluke Connect Assets Optional Software | Yes*, assign images to assets and create work orders. Easily compare objects under test, whether mechanical, electrical or IR images, in the same location |
| tagging of assets | Scan the QR code and Fluke Connect™ helps you automatically organize and archive heat maps! |
| IR-Fusion infrared visible light fusion technology | Continuous fusion, 0 % to 100 %. adds visual detail to IR images. |
| Picture in Picture (PIP) | there are |
| monitor | 3.5" (8.9 cm diagonal) touch screen 640 x 480 LCD |
| Ergonomic design | Designed for one-handed use |
| thermal sensitivity | 40mk |
| Level and span | Smooth auto and manual zoom |
| Fast automatic adjustment in manual mode | there are |
| Minimum range (in manual mode) | 3°C (4.5 °F) |
| Minimum range (in auto mode) | 5°C (9.0 °F) |
| Built-in digital camera (visible light) | 640 x 480 |
| frame rate | 9 Hz or 27 Hz models |
| Dew point calculation | there are |
| Data storage and image capture | |
| random access memory (RAM) | Approx. 500 images |
| external memory | ≥4 GB SD card (>1000 images) |
| Image capture, viewing, and saving mechanisms | One-handed image capture, viewing and saving capabilities |
| Image File Format | Non-infrared BMP or JPEG or full infrared is2 |
| Memory View | there are |
| hardware | Fluke Connect Software - Comprehensive analysis and reporting software with access to Fluke Connect |
| Analyze and store IR data on a PC | there are |
| Exporting File Formats with Fluke Connect Software | is2, BMP, GIF, JPEG, PNG, TIFF |
| Audio notes | Yes, up to 60 seconds of recording when connected to an external device via Bluetooth Audio Headset Profile (HSP). |
| IR-image labeling system | There is a choice of up to 3 additional visible images to be included in the IS2 file. |
| Notes to the text | After completing the IS2 capture, the user can enter comments using the on-screen keyboard. |
| Video Recording and Formatting | Standard video and thermal image video. |
| Auto-capture (temperature and interval) | There is the ability to capture IS2 or Jpeg files at user-selectable intervals. |
| batteries | |
| Battery (field replaceable, rechargeable) | Lithium-ion rechargeable batteries |
| Battery Life | Continuous operating time without WiFi ≥3.5 hours (actual battery life depends on settings and usage) |
| Battery charging time | Fully charged in 2.5 hours |
| Battery charging systems | Ti SBC3B dual-slot battery charger, or charge in a thermal imaging camera. |
| Alternating current operation | Operates on AC power through the included universal power adapter, which has the following output: 15 VDC, 2 A |
| power saving feature | User selectable sleep and shutdown |
| temperature measurement | |
| Temperature range (not calibrated below -10°C) | -20°C to 550°C (not calibrated below -10°C) |
| accurate | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature |
| On-screen emissivity correction | Yes, built-in list of ten common material emissivities, + adjustments between 0.01 and 1.00 |
| palette | |
| Standard color palette | 6 |
| General technical indicators | |
| Color Alarm | Available. User selectable hot and cold spots and internal/external range color alarms. Modify the color palettization of the IR image by limiting the pixels drawn using a pixel temperature based palette color. |
| infrared wavelength | ~8-14μm |
| operating temperature | -10°C to 50°C (14°F to 122°F) |
| storage temperature | -20°C to 50°C (-4°F to 122°F) without battery |
| relative humidity | 10 % to 95 % non-condensing |
| temperature point | Center point (fixed) |
| User definable point markers | Yes, 5 user adjustable temperature point markers. Position is adjustable. The temperature value of the marker is displayed on the screen. The user can choose to turn the display on/off for each marker. |
| User-defined measurement boxes | Yes, 5 user adjustable rectangles. Size and position are adjustable. Rectangle statistics are displayed on the screen: minimum temperature, maximum temperature, and average temperature. The user can choose to turn the display on/off for each marker. |
| Hard carrying case | Rugged hard carrying case with soft case, including adjustable hand strap |
| safety standard | IEC 61010-1: Contamination class 2 |
| electromagnetic compatibility | IEC 61326-1: Portable electromagnetic environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
| Australia RCM | RCM IEC 61326-1 |
| US FCC | 47 CFR subpart 15, section C 15.207, 15.209, 15.249 |
| vibratory | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
| under attack | 30 g, 11 ms, IEC 60068-2-27 |
| fall down | Withstands 2 m drop impact |
| Dimensions (H x W x D) | Approx. (26.7 cm x 10.1 cm x 14.5 cm) Approx. (10.5 in x 4.0 in x 5.7 in) |
| Weight (with battery) | 0.98 kg |
| Shell protection grade | IP54 |
| warranty period | Two years (standard) |
| Recommended calibration intervals | Two years (assuming normal operation and aging) |
| Supported Languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Chinese (Simplified), Spanish, Swedish, Chinese (Traditional) and Turkish. |
| RoHS compliant | there are |
Model: TiS75+ Thermal Imaging Camera
FLK-TIS75+ 27HZ
Fluke TiS75+ Thermal Imaging Camera 27HZ
Included:
- thermal imaging camera
- AC power supply (with universal AC adapter)
- Dual Slot Intelligent Battery Charger
- Two lithium-ion smart batteries
- USB cable
- 4 GB Micro SD Card
- Rugged hard carrying case with soft case and adjustable hand strap
- Available for free download: Fluke Connect™ Software and User Manuals
FLK-TIS75+ 9HZ
Fluke TiS75+ Thermal Imaging Camera 9HZ
Included:
- thermal imaging camera
- AC power supply (with universal AC adapter)
- Dual Slot Intelligent Battery Charger
- Two lithium-ion smart batteries
- USB cable
- 4 GB Micro SD Card
- Rugged hard carrying case with soft case and adjustable hand strap
- Available for free download: Fluke Connect™ Software and User Manuals
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.