Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer
Fluke 561 Infrared and Contact Thermometer

Fluke 561 Infrared and Contact Thermometer

¥999,999.00

Main characteristics

  • Infrared thermometers are able to measure not only close up, but also at a distance, without having to use a ladder at all.
  • The contact temperature measurement function is compatible with all standard small connector type K thermocouples, so you don't need to purchase separate thermocouples for them at all, thus protecting your investment.
  • Velcro® pipe probes can be used for superheat and subcooling measurements as well as other contact and non-contact temperature measurements.
  • Single Point Laser Sighting Measurement
  • Temperature measurement ranges from -40 °C to 550 °C (-40 °F to 1022 °F) are available for most industrial and residential applications.
  • The emission energy can be easily adjusted (high, medium, low) for more precise measurement of pipes and other materials with very smooth surfaces.
  • Lightweight (only 12 ounces/340 grams) for easy portability
  • Easy to use
  • Highly efficient - there is no need to turn off the unit when performing infrared measurements.
  • MIN, MAX, DIF functions help you quickly identify problems
  • Fault scanning is done quickly and efficiently for both small and large objects.

SKU:Fluke 561 Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 561 Infrared and Contact Thermometer

Infrared thermometer with type K thermocouple function

The Fluke 561 Infrared and Contact Pyrometer combines the temperature measurement capabilities technicians in industrial, power, and HVAC industries need, with both infrared and contact temperature measurement, making it a one-piece solution that can be used in multiple applications. It is fast, efficient and easy to use, saving you valuable time and effort. At the same time, you also have the flexibility to choose between contact and infrared temperature measurement. The infrared thermometer measures heat, motion, electricity, and inaccessible objects in moments, and can be used to check motors, insulation, circuit breakers, radiant heat, piping, corroded joints, wiring faults, and to scan HVAC ductwork and other inaccessible objects without using a ladder. When measuring ducts, you can either use the convenient Velcro® duct probe or utilize the standard Type K mini-connector thermocouple probe you have on hand to measure overheating or internal temperatures.

Product Specification: Fluke 561 Infrared and Contact Thermometer

common technical specification
temp -40 to 550 °C (-40 to 1022 °F)
Display resolution 0.1 °C (0.1 °F) of reading
D:S (distance ratio of measuring points) 12:1
Emissivity Quick Selector It can be adjusted between three settings:
Low (0.3), medium (0.7), high (0.95)
Display Accuracy [Assumes ambient operating temperature of 73°F (23°C) to 77°F (25°C) ±1.0 % reading ±1 % reading or ±1 °C (±2 °F), whichever is greater, below 0 °C/32 °F ±1 °C (±2 °F) ± 0.1°/1°
response time <500 mSec (95% of reading)
repetitive ± 0.5% of reading or ±1 °C (±2 °F), whichever is greater
spectral response 8 µm to 14 µm
laser aiming single point laser
Laser off Laser turns off when ambient temperature exceeds 104 °F (40 °C)
laser power Class 2 (II) operation; output <1 mW at 630-670 nm
relative humidity 10% to 90% RH, non-condensing, < 30 °C (86 °F)
Power supply and battery life 2 AA type batteries (alkaline or nichrome)
Battery life 12 hours
The data show that maintaining 7 seconds.
Backlit Display Yes, dual temperature LCDs (current and MAX/MIN/DIF/KTC temperatures), low battery indication, F/C unit indication, and scan/hold option
warranty period 2 years
operating temperature 0 °C to 50 °C (32 °F to 120 °F)
storage temperature -20 °C to 65 °C (-25 °F to 150 °F)
Maximum and minimum temperature and temperature difference there are
Mini-Connector K-Type Thermocouple Input Yes, compatible with industry standard K-type probes with miniature connectors. Displays pyrometer temperature range.
Type K Thermocouple Fabric Hook and Loop Fastener Tube Probe Yes, temperature range 0 °C to 100 °C (32 °F to 212 °F), accuracy ±2.2 °C (±4 °F)
Heating, Ventilation, Air Conditioning and Refrigeration (HVAC) Measurement Guide there are

Model: Fluke 561 Infrared and Contact Thermometer

Fluke 561
Fluke 561 Infrared and Contact Thermometer

Includes.

  • 561 IR thermometer
  • K-Type thermocouple
  • Fabric hook-and-loop fastener pipe probe
  • Hard carrying case
  • 2 AA batteries
  • Users manual
Expand More