Main characteristics

  • Automatically generates and regulates pressure up to 300 psi
  • Easily document the calibration process with on-board test templates
  • Internal automatic pressure fine-tuning
  • Measures, outputs and simulates 4 to 20 mA signals.
  • 24V loop power supply to power the transmitter under test
  • Bright two-channel/three-channel color graphical display
  • HART Communications for Testing HART Smart Transmitters
  • Built-in leak test to verify that the test device is not leaking
  • Rugged, portable design with 3-year standard warranty
  • Compatible with Fluke Connect® Applications
  • Temperature measurement with optional 720RTD probe
  • Measuring Vdc for testing transmitters with 1 Vdc to 5 Vdc outputs
  • Compatible with 700 Series and 750 Series Pressure Modules
  • Upload recorded test results to DPCTrack2™ calibration management software
  • Innovative semi-rigid carrying case for on-site use

Automatic pressure generation and controlUp to 300 psi (20 bar, 2 MPa). Enter a pressure and the 729 automatically pumps up to the desired pressure. Fill out a test template and the 729 automatically pumps up and records a multi-point pressure calibration test.

Simple calibration recordUse the defined transmitter and transducer templates. Type the starting and ending test pressures and the number of test points.729 Additional operations can be performed based on the recorded pressure applied to each test point, the measured mA current, and the error %. A bright color graphical display highlights out-of-tolerance test results in red.

Internal automatic pressure fine-tuningHelps compensate for minor leaks in hoses and test fixtures. Eliminates the need to manually turn the vernier to compensate for leaks, helping to avoid the hassle of manually pumping and manually fine-tuning test fixtures.

HART communicationEnables mA output adjustment to the value of the application and pressure zero correction for HART pressure transmitters. You can also easily perform configuration tasks such as changing transmitter labels, units of measure, and ranges. Other supported HART commands include: setting a fixed mA output for troubleshooting, reading device configuration parameters, and reading device diagnostic data.

Measurement of mA signals from transmitters, outputs and analog mA signalsFor testing I/P and other mA loop devices. A 24V loop power supply is included for testing and powering the transmitter during stand-alone testing of an isolated control system.

Rugged portable designWith a 3-year warranty, the 729 is unique compared to most other pressure calibrators. 729 has been tested and guaranteed to withstand a 1-meter drop test for on-site instrument calibration operations.

Fluke Connect® CompatibilityEnables users to perform remote monitoring using the Fluke Connect mobile app, as well as manage and store pressure measurements and log events. Share measurements using ShareLive™ video calls and email capabilities.

measured temperatureUtilizing the optional 720RTD probe [32]

Pressure measurementWhen different pressure measurement ranges or resolutions are required, the original 700 Series and 750 Series pressure modules can be utilized [34].

Multi-language support: Select the language from the instrument setup program. HART communication commands are limited to English according to the HART device description and protocol.

Semi-rigid caseFor field operations, the case stores test hoses, fittings, test leads and small hand tools needed for on-site pressure calibration.

SKU:Fluke 729 Category. Brand.

Inquire about this product

Product Overview: Fluke 729 Automatic Pressure Calibrator

Portable Automatic Pressure Calibrator Simplifies Pressure Calibration

Designed for process technicians, the Fluke 729 Automatic Pressure Calibrator simplifies the pressure calibration process and provides fast, accurate test results. Technicians know that calibrating pressures can be a time-consuming task, and the 729 makes the process easier than ever with its internal motorized pump, which automates pressure generation and adjustment in an easy-to-use, rugged, portable toolkit.

The 729 is the ideal portable pressure calibrator. Simply enter the target pressure and the calibrator automatically pressurizes to the desired set point. The internal micro-regulator then automatically stabilizes the pressure at the required value.

The Fluke 729 can also automatically test multiple pressure points and automatically record the results. Calibration is also fairly simple. Simply enter the start and end pressures, as well as the number of test points and the tolerance level. The 729 does the rest.

Built-in HART communication enables HART transmitter mA adjustment, easy HART configuration, and adjustment to the applied 0% and 100% values.

Uploading and managing recorded calibration results with DPCTrack2™ calibration management software makes it easy to manage your instruments, create scheduled tests and reports, and manage calibration data.

The Fluke 729 Automatic Pressure Calibrator offers optional ranges of 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa), and 300 psi (20 bar, 2 Mpa) so you can perform calibrations anytime, anywhere.

Product Specifications: Fluke 729 Automatic Pressure Calibrator

Pressure specification*
One-year specification, 0.02% at full scale
Control specification, 0.005% of full scale minimum
*Refer to the manual for detailed specifications

 

model number
729 30G
Psi Range, Resolution -12.0000 to 30.0000 psi
Bar Range, Resolution -0.82737 - 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
marginal notes No wireless communication provided
729 150G
Psi Range, Resolution -12.000 to 150.000 psi
Bar Range, Resolution -0.8273 - 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
marginal notes No wireless communication provided
729 300G
Psi Range, Resolution -12.000 to 300.000 psi
Bar Range, Resolution -0.8273 - 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
marginal notes No wireless communication provided
729 30G FC
Psi Range, Resolution -12.0000 to 30.0000 psi
Bar Range, Resolution -0.82737 - 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
marginal notes Wireless Communication for Fluke Connect
729 150G FC
Psi Range, Resolution -12.000 to 150.000 psi
Bar Range, Resolution -0.8273 - 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
marginal notes Wireless Communication for Fluke Connect
729 300G FC
Psi Range, Resolution -12.000 to 300.000 psi
Bar Range, Resolution -0.8273 - 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
marginal notes Wireless Communication for Fluke Connect
729CN 200K
Psi Range, Resolution -12.0000 to 30.0000 psi
Bar Range, Resolution -0.82737 - 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
marginal notes For China, no wireless communication provided
729CN 1M
Psi Range, Resolution -12.000 to 150.000 psi
Bar Range, Resolution -0.8273 - 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
marginal notes For China, no wireless communication provided
729CN 2M
Psi Range, Resolution -12.000 to 300.000 psi
Bar Range, Resolution -0.8273 - 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
marginal notes For China, no wireless communication provided
729CN 200K FC
Psi Range, Resolution -12.0000 to 30.0000 psi
Bar Range, Resolution -0.82737 - 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
marginal notes For China, Wireless Communications for Fluke Connect
729CN 1M FC
Psi Range, Resolution -12.000 to 150.000 psi
Bar Range, Resolution -0.8273 - 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
marginal notes For China, Wireless Communications for Fluke Connect
729CN 2M FC
Psi Range, Resolution -12.000 to 300.000 psi
Bar Range, Resolution -0.8273 - 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
marginal notes For China, Wireless Communications for Fluke Connect
729PLUS 2M 729 Automatic pressure calibrator, 2Mpa, Chinese version, with FC function, with Chinese report software
729PLUS 1M 729 Automatic pressure calibrator, 1Mpa, Chinese version, with FC function, with Chinese report software
729PLUS 200K 729 Automatic Pressure Calibrator, 200kPa, Chinese version, with FC function, with Chinese reporting software
729JP 200K
kPa range, resolution -82.737 to 206.843 kPa
marginal notes For Japan, no wireless communication
729JP 1M
kPa range, resolution -82.73 to 1034.21 kPa
marginal notes For Japan, 1 Mpa range, no wireless communication available
729JP 2M
kPa range, resolution -82.73 to 2068.43 kPa
marginal notes For Japan, 2 Mpa range, no wireless communication available
729JP 200K FC
kPa range, resolution -82.737 to 206.843 kPa
marginal notes For Japan, Wireless Communications for Fluke Connect
729JP 1M FC
kPa range, resolution -82.73 to 1034.21 kPa
marginal notes For Japan, Wireless Communications for Fluke Connect
729JP 2M FC
kPa range, resolution -82.73 to 2068.43 kPa
marginal notes For Japan, Wireless Communications for Fluke Connect

 

Electrical specifications
All specifications apply to the 110% range (except 24 mA output and analog, which apply to the 100% range).
range (of scales or measuring equipment)
mA measurement, output and analog 0 mA to 24 mA
DC Voltage Measurement 0 V dc to 30 V dc
resolution (of a photo)
mA DC output, analog and measurement 1 μA
DC Voltage Measurement 1 mV
accurate 0.01% ± 2 LSD for all ranges (at 23 °C ± 5 °C)
degree of stability Full scale 20 ppm/°C (-10 °C to +18 °C and 28 °C to +50 °C)
mA Analog External Voltage Requirements 12 V dc to 30 V dc
Loop Compliance Voltage 24 V dc (at 20 mA)
mA Analog External Voltage Requirements 12 V dc to 30 V dc
Temperature measurement only/100 Ω Pt(385) RTD -50 °C to 150 °C (-58 °F to 302 °F)
Temperature resolution 0.01 °C (0.01 °F)
Temperature Accuracy ± 0.1 °C (0.2 °F) ± 0.25 °C (± 0.45 °F) Synthesized Uncertainty (when using 720 RTD probe (optional accessory))
driving ability 1200 Ω (without HART resistor), 950 Ω (with HART resistor)
Mechanical technical indicators
Volume (H x W x L) 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
weights 6.5 lbs. (2.95 kg)
protection class IP54
Environmental specifications
operating temperature -10 °C to 50 °C (for measurement), 0 °C to 50 °C (for pressure control)
Battery operating temperature -10 °C to 40 °C
Battery reaches 40 °C only when charging
storage temperature -40 °C to 60 °C
Working altitude 3000 m
Storage altitude 13000 m
Wireless (729 FC only)
Radio frequency certification FCC ID: T68-FBLE IC:6627A-FBLE
Radio frequency range 2412 MHz to 2462 MHz

Model: Fluke 729 Automatic Pressure Calibrator

FLK-729 30G
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, no wireless communication
FLK-729 150G
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, no wireless communication
FLK-729 300G
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, no wireless communication
FLK-729 30G FC
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, includes wireless communication for Fluke Connect
FLK-729 150G FC
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, includes wireless communication for Fluke Connect
FLK-729 300G FC
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, includes wireless communication for Fluke Connect
FLK-729CN 200K
Fluke 729CN 200K, 200 kPa Fully Automatic Pressure Calibrator, China
For China, 200 kPa range, no wireless communication available
FLK-729CN 1M
Fluke 729CN 1M, 1MPa Fully Automatic Pressure Calibrator, China
For China, 1MPa range, no wireless communication available
FLK-729CN 2M
Fluke 729CN 2M, 2 MPa Fully Automatic Pressure Calibrator, China
For China, 2 MPa range, no wireless communication available
FLK-729CN 200K FC
Fluke 729CN 200K FC, 200 kPa Fully Automatic Pressure Calibrator, China, with Fluke Connect
For China, 200 kPa range, wireless communication included, for Fluke Connect
FLK-729CN 1M FC
Fluke 729CN 1M FC, 1 MPa Fully Automatic Pressure Calibrator, China, with Fluke Connect
For China, 1 MPa Range, Wireless Communication Included, for Fluke Connect
FLK-729CN 2M FC
Fluke 729CN 2M FC, 2 MPa Fully Automatic Pressure Calibrator, China, with Fluke Connect
For China, 2 MPa Range, Wireless Communication Included, for Fluke Connect
FLK-729PLUS 2M
729 Automatic pressure calibrator, 2Mpa, Chinese version, with FC function, with Chinese report software
FLK-729PLUS 1M
729 Automatic pressure calibrator, 1Mpa, Chinese version, with FC function, with Chinese report software
FLK-729PLUS 200K
729 Automatic Pressure Calibrator, 200kPa, Chinese version, with FC function, with Chinese reporting software

F729 Technical Parameters [please login to download and view]

F729 User's Manual [Please login to download and view].

 

Expand More
Fluke 729 Automatic Pressure CalibratorFluke 729 Automatic Pressure Calibrator

Click to enquire

Product consultation and purchase:18218718851

I already understand