Flexible Current Probes RCP Series
Flexible Current Probes RCP Series
Flexible Current Probes RCP Series
Flexible Current Probes RCP Series
Flexible Current Probes RCP Series
Flexible Current Probes RCP Series
Flexible Current Probes RCP Series
Flexible Current Probes RCP Series

Flexible Current Probes RCP Series

¥999,999.00
  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Flexible Current ProbesRCP Series

Bandwidth: 2Hz-30MHz

Coil cross-section diameter: approx. 1.6mm

Typical Accuracy: 2%

Peak current: 12000Apk

Interface: Standard BNC

Micsig flexible current probe (Roche coil) RCP series has a bandwidth of up to 30MHz, the maximum measurable current up to 12000Apk, the probe's withstand voltage value of up to 1kVrms, the insertion impedance is almost zero, the most significant reduction in the interference of the object under test.

The ultra-small 1.6mm coil cross-section diameter allows for easy passage through the pins of TO-220 semiconductor devices. Typical accuracy is up to 2% for precise measurement of high frequency high current signals. Ideal for third-generation semiconductor double-pulse dynamic testing, monitoring semiconductor switching current waveforms, and more.

Flexible Current Probes

Measurement of MOSFET Id Current

With excellent high-frequency characteristics, the RCP series can easily cope with high-speed signals and fast-changing current waveforms, helping you to observe high-frequency harmonic components when measuring the Id current of MOSFETs (oscillating portion of the waveform in the figure).

The excellent response time of RCP series can quickly capture, measure and feedback the real-time current condition of MOSFETs, so that you can get twice the result with half the effort in design and debugging process.

Extremely small coil cross-section diameter

With a cross-section diameter of only 1.6mm, the coil can easily pass through semiconductor devices with narrow chip pin spacing (e.g. TO-220, TO-47).

Coil design is lightweight and flexible, easy to plug and unplug, to solve the problem of hard probe hard to reach areas, easy to realize the connection with the object under test, while the probe coil diameter can be customized according to customer needs, to meet a variety of special occasions test requirements

BNC connector for worry-free adaptation

Adopts standard BNC interface design, suitable for all brands of oscilloscopes.

appliance

● Measurement of currents in motor drives, such as power quality measurements in variable speed drives (VSDs), uninterruptible power supplies (UPSs) or switching mode power supply (SMPS) circuits
Measurement of pin currents of MOSFETs and IGBTs made of silicon carbide SiC, gallium nitride GaN, etc., for double-pulse testing.
:: Monitoring of currents in small inductors, capacitors, and dissipation circuits
● Measurement of load currents and high harmonic currents in power electronics
● Measurement of small AC currents in the presence of large DC currents
● Measurement of high-frequency sinusoidal, pulse or transient currents
:: Measurement of AC current in three-phase power supply systems
:: Measurement of power loss in semiconductors
● Measurement of 50/60Hz industrial frequency current
:: Power converter development and diagnostics

Application of flexible current probes

model number RCP60XS RCP120XS RCP300XS RCP600XS RCP1200XS RCP3000XS RCP6000XS RCP12000XS
bandwidths 85Hz - 30MHz  34Hz - 30MHz 10Hz - 30MHz 10Hz - 30MHz 12Hz - 30MHz 3Hz - 30MHz 2Hz - 30MHz 2Hz - 30MHz
peak current 60Apk 120Apk 300Apk 600Apk 1200Apk 3000 Apk 6000 Apk 12000 Apk
Output sensitivity 100mV/A (10x) 50mV/A (20x) 20mV/A (50X) 10mV/A (100X) 5mV/A (200X) 2mV/A (500X) 1mV/A (1000X) 0.5 mV/A (2000X)
Typical Accuracy 2% 2% 2% 2% 2% 2% 2% 2%
Rate of change of current (peak) 4kA/μs 8kA/μs 20kA/μs 40kA/μs 70kA/μs 70kA/μs 70kA/μs 70kA/μs
Attenuation Characteristics 65%/ms 35%/ms 9%/ms 6%/ms 3%/ms 2%/ms 2%/ms 2%/ms
output noise <20mVpp  <20mVpp <18mVpp <12mVpp <5mVpp <5mVpp <5mVpp <6mVpp
pressure resistance AC 1kVrms (1 minute) (50Hz/60Hz) (Rochester coil section only)
Wire length 1.5m, refers to the length from the integrator to the Roche coil, supports customization
Rochester coil inner diameter 25mm, can measure wires up to 20mm in diameter, supports customization.
Rochester coil perimeter 80mm, support customization
Rochester coil cross-section diameter Approx. 1.6mm
Output Impedance 1MΩ
Oscilloscope Side Interface Universal standard BNC connector, can be used with all brands of oscilloscopes