IT-M3800 Series Feedback DC Electronic Load
IT-M3800 Series Feedback DC Electronic Load
IT-M3800 Series Feedback DC Electronic Load
IT-M3800 Series Feedback DC Electronic Load
IT-M3800 Series Feedback DC Electronic Load
IT-M3800 Series Feedback DC Electronic Load

IT-M3800 Series Feedback DC Electronic Load

¥99,999.00

IT-M3800 series feed-back DC electronic loads can simulate various load characteristics and also feed power back to the grid without pollution, which not only saves power and heat dissipation costs for users, but also meets the demand for energy saving and environmental protection. With high-precision output and measurement, and a number of safety designs for testing, it is suitable for use in a variety of testing fields, such as 5G communication and data centers, industrial components, aging testing, photovoltaic energy storage, power optimizers, etc.

SKU:IT-M3800 Categories. , Tag. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Features

Compact design, 1U@6kW, 2U@12kW
Voltage range: 10~1500V
Current range: 8A~720A
Power range: 12kW
Simple master/slave parallel connection to expand power while maintaining performance*1
♦ Efficient and environmentally friendly energy return, effectively reducing electricity and cooling costs
♦ Voltage, current, power Adjustable up/down slope
Battery discharge test function
Short circuit analog function
♦ List function, up to 200 steps can be set up
♦ 8 operation modes: CC/CV/CP/CW/CC+CV/CV+CR/CR+CC/CC+CV+CW+CR operation modes
Von function to control the On/Off state of the instrument.
Multiple protection functions: OVP, ± OCP, ± OPP, OTP, power-down protection, islanding protection.
♦ Automatic detection of power grid status for reliable grid-connection function
USB/CAN/LAN/Digital IO interface as standard, and optional GPIB/Analog & RS232 interface*1 1U model >16 units in parallel, 2U model >8 units in parallel Please contact ITECH for details.

Product Features and Benefits

Application Areas

 

 

High power density, compact design

 

ITECH has been adhering to the high power density design concept to help customers to optimize the test solution. IT-M3800 series can provide up to 6kW of power in a 1U chassis, and up to 12kW of power in a 2U chassis, which makes ITECH's entire high power density product line more complete and comprehensive.

 

Wide range design, one for many

 

IT-M3800 series has 25 models, the single voltage from 10V to 1500V, single current up to 720A. adopts a wide range of output design, compared with the traditional fixed-range output DC loads, provides users with more voltage and current combinations, so that the use of more flexible. A single load can cover a wide range of application requirements, significantly reducing the complexity of system construction and space occupied.

 

Efficient energy return

 

The IT-M3800 has an energy recovery function, which can return power to the grid without pollution, and the return can be up to nearly 95%. All the return processes are automatic and safe, and the IT-M3800 is equipped with an automatic grid detection system, which detects the phase voltage and frequency in real time for grid synchronization. It not only saves the cost of electricity, HVAC and refrigeration facilities and reduces noise, but also helps to reduce carbon emissions and protect the environment.

 

Power accumulation, energy saving at a glance

 

IT-M3800 series utilizes power electronic conversion technology to recycle and reuse the output energy of the power supply under test on the premise of completing the test power experiment. Through internal high-speed voltage and current sampling, users can directly view the current power parameters in the instrument panel, including the voltage, frequency and power of each phase. You can also view the total power, the current total power back and the historical total power back, so the energy-saving effect is clear at a glance. After power failure and reboot, IT-M3800 series can continue to accumulate power based on the power before the last power off.

 

Battery Discharge Test

 

The IT-M3800 series is equipped with a discharge test function, which is suitable for discharging all kinds of portable batteries. Three test shutdown conditions can be set by yourself: shutdown voltage, shutdown capacity and discharge time. When any one of the three conditions is met, the test will be automatically interrupted. Battery voltage, discharge time and discharged capacity can be observed during the test.

 

Highly efficient parallel technology

 

Considering the convenience and versatility of users, IT-M3800 utilizes the master/slave control mode, which allows multiple loads to be connected in parallel to meet high-power testing needs. Meanwhile, it adopts fiber optic parallel technology to fully solve the problems of slow speed and poor accuracy that exist in the traditional parallel mode, which is suitable for calibration and metrology, R&D labs, production lines and ATE test setups.

 

Multiple operating modes

 

The IT-M3800 is equipped with CC/CV/CW/CR basic operation modes.

The IT-M3800 is equipped with four compound operation modes, including CC+CR, CV+CR, CV+CC and CC+CV+CW+CR, which can be adapted to the testing needs of a wide range of occasions.

model numberinput voltageampspower (output)resolution (of a photo)mythical goblin spirit degree (angles, temperature etc)take over for sb. mouthsizes
IT-M3801-10-12010V3 to 120A12 to 1200W0.001V/0.1A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3802-10-24010V4~240A40~2400W0.001V/0.1A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3803-10-36010V6~360A60~3600W0.001V/0.1A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3807-10-72010V12~720A120~7200W0.001V/0.1A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U
IT-M3802-32-8032V80A2kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3804-32-16032V160A4kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3806-32-24032V240A6kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3812-32-48032V480A12kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U
IT-M3802-80-4080V40A2kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3804-80-8080V80A4kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3806-80-12080V120A6kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3812-80-24080V240A12kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U
IT-M3802-300-20300V20A2kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3804-300-40300V40A4kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3806-300-60300V60A6kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3812-300-120300V120A12kW0.001V/0.01A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U
IT-M3802-500-12500V12A2kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3804-500-24500V24A4kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3806-500-36500V36A6kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3812-500-72500V72A12kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U
IT-M3802-800-8800V8A2kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3804-800-16800V16A4kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3806-800-24800V24A6kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3812-800-48800V48A12kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U
IT-M3806-1500-121500V12A6kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2321 U
IT-M3812-1500-241500V24A12kW0.01V/0.001A≤0.03% + 0.03%FS / ≤0.1% + 0.1%FSUSB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS2322 U

IT-M3800 series product leaflet [Please login to download and view].

IT-M3800 series communication protocol [Please login to download and view].

IT-M3800 Series User's Manual [Please login to download and view]

Expand More
IT-M3800 Series Feedback DC Electronic LoadIT-M3800 Series Feedback DC Electronic Load
¥99,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand