ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge
ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge
ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge
ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge
ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge
ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge

ZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge

ZC2876/ZC2877/ZC2878 High Frequency Precision Bridge is a multi-functional component tester used for inspection of various electronic components. It adopts 7-inch 800×480 color TFT LCD display, which enables users to read out the test results more intuitively and comfortably. It is a high speed, wide test range, 6-bit test resolution impedance measuring instrument, which can meet the production line quality assurance, incoming inspection and laboratory measurement requirements.

Category. Tags. , Brand.

Inquire about this product

brief introduction

ZC2876/ZC2877/ZC2878 High Frequency Precision Bridge is a multi-functional component tester used for inspection of various electronic components. Its 7-inch 800x480 color TFT LCD display enables users to read out the test results more intuitively and comfortably. It is a high speed, wide test range, 6-bit test resolution impedance measuring instrument, which can meet the production line quality assurance, incoming inspection and laboratory measurement requirements.

Performance Characteristics

  • Four-parameter display, any combination of parameters, up to 12 measurement parameters
  • 7-inch 16:9 TFT LCD display with 800x480 RGB resolution
  • 0.05% basic measurement accuracy with fast test speed (200 tests/second)
  • 20Hz-5MHz test frequency with 10 mHz resolution
  • Measuring speed up to 200 times/s
  • Automatic level control ALC function for test voltage or current
  • 30 Ω, 100 Ω, 50 Ω, 10/CC four different signal source output impedance
  • Built-in comparator, 10-speed sorting and counting function
  • Frequency response curve plot analysis function
  • 10-point list scanning function
  • Internal -5V~+5V DC bias voltage source
  • Selectable ±10V (±100mA) and 1 A internal DC bias source
  • Internal 100 sets of setup files to save or recall, USB flash drive 500 sets of test files to save or recall
  • Upgrade and update of the instrument software version can be realized via USB HOST.
  • USB flash drive can support format FAT16, FAT32 file system
  • Standard RS232C, HANDLER, USB HOST, headphone jack, optional GPIB, LAN interface

Technical indicators

Operating temperature, humidity 0°C-40°C, 90%RH
Power Requirements input voltage 99v-121v 198v-242v
frequency 47.5Hz-63Hz
power wastage ≤80VA
Volume (W*H*D) 398mm×129mm×370mm
weights Approx. 9kg

Technical Parameters

Instrument Model

ZC2878

ZC2877

ZC2876

measurement function

test parameter

|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR

Basic Measurement Accuracy

0.05%

0.05%

equivalent circuit

Series, Parallel

math function

Value deviation, percentage deviation

Measurement range

Auto, Hold, Manual Selection

trigger method

Internal, Manual, External, Bus

Measurement speed (≥1kHz)

Fast: 75 times/second (fast)
Medium speed: 50 times/second
Slow: 5 times/second
Fast: 200 times/second (fast)
Medium speed: 40 times/second
Slow: 5 times/second

Average number of times

1-255

latency

0-60s in 1ms steps

calibration function

Open / Short / Load

Test Side Configuration

five extremes

List Scanning

10-point list scanning function

Display mode

Direct reading, Δ, Δ%, V/I (measured voltage/current monitoring)

monitor (computer)

6-bit resolution, 800 x 480 RGB7-inch 16: 9 TFT LCD display

test signal

Test Signal Frequency

20 Hz-1MHz, 10mHz resolution

20 Hz-2MHz, 10mHz resolution

20 Hz-5MHz, 10mHz resolution

Output Impedance

30Ω, 100Ω, 50Ω, 10 / CC selectable

Test Signal Level

Normal: 5 mV-2V
Accuracy: 10% in 1 mV steps
Constant level: 10 mV-1 V Accuracy: 5% in 1 mV steps
Normal: 5 mV-5V Accuracy: 10% in 1 mV steps
Constant Level: 10mV-1V Accuracy: 5% in 1 mV steps

DC Bias Source

inside (part, section)

0V, 1.5V, 2V

0V-5V continuously adjustable, 1mV steps

optional

ZC6802A: 0-10V DC bias voltage, 0-100mA DC bias current

ZC6802B: 0-1A DC bias current

Display range

|Z|, R, X

0.01m Ω - 99.9999 MΩ

DCR

1 mΩ - 99.9999 MΩ

|Y|, G, B

0.00001µS - 99.9999 S

C

0.00001 pF - 9.9999 F

L

0.00001 µH - 9999.99 H

D

0.00001 - 9.9999

Q

0.00001 - 9999.9

θ (DEG)

-179.999°- 179.999°

θ (RAD)

-3.14159 - 3.14159

(sth. or sb) else

Comparator Functions

Ten gears: (nine pass, one fail) and one additional accessory gear AUX

memory (unit)

100 sets of internal instrument settings for storage/recall

connector

RS-232C, HANDLER, GPIB (option), LAN (option), USBTMC, USBCDC

Expand More
ZC2876/ZC2877/ZC2878 High Frequency LCR Digital BridgeZC2876/ZC2877/ZC2878 High Frequency LCR Digital Bridge

Click to enquire

Product consultation and purchase:18218718851

I already understand