■ Multi-Channel Handheld Data Logger
The new generation of DAS 220 loggers is designed to test the parameters you need to record in your process: voltage test sensor test (0-10V), temperature test (thermocouple, PT100-PT1000), current test (optional shunt) resistance test, counting, frequency. You can visualize the test results (graphic and numerical) and store them inside the logger or on USB. You can transfer and process the data on your PC using the license-free Das Lab software.
■ Humanized interface
DAS220 with 10" touch screen: the user interface is very interactive. Icons and symbols make navigation very easy and time-saving.
Technical indicators | |
Number of channels: | 10 channels |
Input metrics | |
dc voltage | |
Range: | 1mV (±0.5Mv) to 200V (±100V) |
Maximum input voltage: | DC 100V |
Precision: | 0.1% at full scale, ±10μV |
Temperature band thermocouple | |
transducers | realm |
Couple J | -210°C - 1200°C |
Couple K | -250°C - 1370°C |
Couple T | -200°C - 400°C |
Couple S | -50°C - 1760°C |
Couple B | 200°C - 1820°C |
Couple E | -250°C - 1000°C |
Couple N | -250°C - 1300°C |
Couple C | 0°C - 2320°C |
Couple L | -200°C - 900°C |
Accuracy Cold End Temperature Compensation ±1.25% | |
Temperature bands PT100-PT1000 | |
Current: | 1mA (Pt100) & 100μA (Pt1000) |
Range: | -200°C to 850°C |
Testing: | Line 2, Line 3 |
Accuracy (20°C): | 0.3°C ± 0.1% of reading |
2-wire compensation resistor: | Maximum 30Ω |
3-wire compensation resistor: | Maximum 50Ω |
resistive | |
Range: | 1kΩ 10Kω |
Precision: | 1Ω (range 1kΩ) and 10Ω (10kΩ) |
Acquisition-Sampling | |
Resolution: | 16-bit |
Get the system: | Scanning, sampling per channel |
Sample rate: | 1ms to 20mn V >50mV
2ms to 20mn V ≤50mV. Thermocouples & Pt100-Pt1000 |
Trigger. | Date, Delay, Queue, Queue Combination (and/or)
The text of the logical channel (and, or, slope, the (Levels) |
Pre-trigger. | Variable sampling from 0-100k |
Additional I/O | |
logical channel | |
Quantity: | 12 |
Maximum permissible voltage: | 24V Cat I |
Input Impedance: | 4.7kΩ |
Sample rate: | Maximum 1ms |
Logic Function Inputs | |
Number of channels: | 4 (K1-K4) |
Maximum permissible voltage: | 24V Cat I |
Sample rate: | Maximum 1ms |
Pulse counting: | 0-10000000 |
Frequency testing: | 1Hz to 10kHz |
Alarm (output) | |
Quantity: | 4 alarms (A,B,C,D) |
Output Level: | 0-5V |
Comes with: | 100/240V mains adapter, instruction manual (CDROM),
1 male 25-pole connector Connector, stylus, rag, screwdriver |
Requires DAS220 with battery: | DAS220 BAT |
internal storage | |
Internal flash drive: | Minimum 32GB |
Maximum file size. | 2GB |
connector | |
USB. | 2 Type A USB |
Ethernet. | 10/100 Twisted pair with RJ45 |
Wifi. | Optional USB adapter |
General specifications | |
demonstrate | 10 inch TFTLCD touch screen, backlight, 1024*600 |
power supply | 10V/4A max with mains adapter (100/240VAC) |
batteries | Factory Option, Non-Detachable, Li-Ion Battery |
Battery Standby | 15 hours in standby mode, 10 hours in non-standby mode |
operating temperature | 0 °C -40 °C, 80% RH (non-condensing) |
Storage temperature | -20°C - 60°C |
sizes | 210*295*105mm |
weights | 2.5kg |
surety | CAT I 100V according to IEC61010-1 |
warranty period | 2 years |
Selection Guide | DAS220 | DAS220BAT |
10 analog multichannel | - | - |
12 Logic Channel Inputs | - | - |
Internal battery (8h standby) | - | - |
WiFi Interface (USB Networking) | option | option |
Optional accessories | |
Sturdy suitcase | P/N:902408000 |
Wifi (USBA adapter) | P/N: 902402000 |
12 isolated logic passes | P/N:984405500 |
Logic Channel Flex Cable | P/N:902407000 |
4-20 Ma/50 Ohm Shunt | P/N:902406500 |
19" up | P/N:902209000 |
DIN machine | P/N:902201000 |
■ 10 analog channels, 12 logic channels
■ Maximum 1ms sampling speed per channel
■ 100kHz bandwidth
■ 32GB internal hard drive
■ 无内置电池
■ Universal inputs: voltage, thermocouple, PT100-1000, current (optional adaptations required)
(device), resistor
■ Voltage: 1mV to 200V (±100V)
■ Temperature: Thermocouple (all types), Pt100/Pt1000 (2 or 3 wire)
■ 4 alarms (outputs)
■ 4 logic function inputs with counter and frequency meter functions
■ 16-bit resolution
■ 10" TFT panoramic touchscreen
■ Interfaces: USB, Ethernet, WiFi (optional)
■ Li-Ion battery (factory option): 15h standby
▪ DasLab software (license-free)
■ Safety standards: IEC61010 CAT I 100V
■ The DAS220 is a very versatile recorder in the field of process testing.
- Multi-channel temperature monitoring and recording
- 0-10V Sensor monitoring and recording
- voltage test
- pulse counting