● Industry's high-precision AC-IR and DCV measurement function
- AC-IR up to 10 nΩ resolution, 5½ digits: excellent resolution and stability for resistance measurements
- DCV up to 1 µV resolution, 7½ digits: Voltage measurement accuracy that rivals high-precision voltmeters
● Simultaneous measurement of the true value of ΩV: the fastest checking time is 12ms, which reduces the checking time by half while ensuring stability.
:: Applicable to production lines for large-capacity batteries with an internal resistance of 1 mΩ or less.
- High-precision sorting for shipment inspection: BT6075
- For OCV/IR testing during initial process, defective product detection: BT6065
Basic parameters (1 year accuracy guarantee)
| Resistance Measurement Range
(high resolution on) |
[Range (Measuring current), Accuracy (SLOW2), Max. display value, Resolution]
3 mΩ (300 mA), ±0.08% rdg. ±0.08 μΩ, 5.10000 mΩ, 0.01 μΩ 3 mΩ (100 mA), ±0.08% rdg. ±0.50 μΩ, 5.10000 mΩ, 0.01 μΩ 30 mΩ (100 mA), ±0.08% rdg. ±0.5 μΩ, 51.0000 mΩ, 0.1 μΩ 300 mΩ (10 mA), ±0.08% rdg. ±5 μΩ, 510.000 mΩ, 1 μΩ 3 Ω (1 mA), ±0.10% rdg. ±50 μΩ, 5.10000 Ω, 10 μΩ 30 Ω (100 μA), ±0.15% rdg. ±0.5 mΩ, 51.0000 Ω, 100 μΩ Measured current frequency: 1 kHz ±0.2 Hz Additional precision Temperature coefficient: The following values are added to the measurement accuracy for environments of 0℃ to 18℃, 28℃ to 40℃. (Measurement accuracy × 0.1)/°C Resistance Measurement MIR Mode: Resistance Measurement Accuracy Increase of ±0.01% of the reading. |
|---|---|
| DC voltage measurement range | [Name: Range, SLOW2, Maximum display value, Resolution]
BT6065: 10 V, ±0.002% rdg. ±20 μV, ±12.00000 V, 10 μV BT6065: 100 V, ±0.004% rdg. ±0.6 mV, ±120.0000 V, 100 μV BT6075: 10 V, ±0.0012% rdg. ±11 μV, ±12.000000 V, 1 μV BT6075: 100 V, ±0.003% rdg. ±0.60 mV, ±120.00000 V, 10 μV Additional precision Temperature coefficient: The following values are added to the measurement accuracy for environments of 0℃ to 18℃, 28℃ to 40℃. (Measurement accuracy × 0.1)/°C |
| Temperature measurement range | Range: -10.0℃~60.0℃
Accuracy (Main unit + Z2005): ±0.5℃ (Measurement temperature 10. 0℃~40.0℃), ±1.0℃ (Measurement temperature -10.0℃~9.9℃, 40.1℃~60.0℃) |
| Loop resistance measurement range | [Resistance range, Resistance measurement current, Maximum display value]
3 mΩ, 300 mA, 10.0 Ω 3 mΩ, 100 mA, 50.0 Ω 30 mΩ, 100 mA, 50.0 Ω 300 mΩ, 10 mA, 50.0 Ω 3 Ω, 1 mA, 50.0 Ω 30 Ω, 100 μA, 500 Ω |
| Sampling time(*1) | [power supply frequency, FAST1, FAST2, MEDIUM1(MED1), MEDIUM2(MED2), SLOW1, SLOW2]
50 Hz, 4 ms, 10 ms, 20 ms, 40 ms, 100 ms, 200 ms 60 Hz, 4 ms, 10 ms, 17 ms, 33 ms, 100 ms, 200 ms *1: Measurement functions ΩV, Ω, V universal |
| corresponding time | When measuring a 4V battery, pure resistance measurement: approx. 8ms |
| functionality | Average (1 time ~ 256 times)), Contact Check, Resistance Self-Calibration, DC Voltage Self-Calibration, Zeroing (CH528), Multi-Channel Calibration (CH528), Loop Resistance Detection, Resistance Measurement MIR Mode (Mutual Interference Reduction Mode), Comparator, Command Compatibility (Battery Tester BT3562A Upper Compatible), Panel Save (Number of Saved Groups: 6), Communication Monitor, EXT. Compatible), Panel Save (No. of Saved Groups: 6), Communication Monitor, EXT. |
| connector | LAN (10BASE T/100BASE-T, TCP/IP), USB (COM Mode, Connector C), USB (MEM Mode, Connector A Type, Z4006 USB Disk Use), RS-232C (9600 bps, 19200 bps, 38400 bps), EXT. I/O |
| power supply | Rated supply voltage: AC 100 V to 240 V
Rated power frequency: 50 Hz, 60 Hz Maximum power rating: 40 VA |
| Volume-Weight | Approx. 215 (W) × 88 (H) × 313 (D) mm, approx. 3.1 kg (excluding protrusions) |
| attachment (email) | Power cord × 1, Startup guide × 1, Precautions for use × 1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.