● Measurement of MLCC leakage current as fast as 6.8ms, 8ch simultaneous measurement
● High-speed measurement of leakage current in high-capacity MLCCs with a large current range (1mA).
:: Increased reliability of inspections through the contact inspection function
● Individual setting of each channel enables the construction of a flexible system.
The Super Insulation Meter SM7810 is a special note item. Connecting cables for input/output ports are sold separately, please inquire first.
*Connectors/plugs and cables related to input/output ports
● The connector for the current input port and the plug for the voltage output port are not standard accessories. The connector for the voltage input port is a standard accessory.
● We have other cables for various input ports of different lengths to suit various measurement needs, so please inquire in advance if you need to purchase them separately.
*Connectors/plugs and cables related to input/output ports
● The connector for the current input port and the plug for the voltage output port are not standard accessories. The connector for the voltage input port is a standard accessory.
● We have other cables for various input ports of different lengths to suit various measurement needs, so please inquire in advance if you need to purchase them separately.
Technical parameters (accuracy guaranteed for 1 year, warm-up time over 1 hour)
| channel number | 8 channels (side-by-side for simultaneous measurement) |
|---|---|
| applied voltage | Power supply via external power supply (back voltage input connector input) |
| Measurement range | Current: 1pA~1mA Range: 100pA/1nA/10nA/100nA/1μA/10μA/100μA/1mA Resistance: 1×102Ω ~ 1×1015Ω |
| Measured speed, INDEX representative value | FAST: 6.8ms, MED: 26.0ms, SLOW: 100.0ms, SLOW2:320.0ms |
| Basic Measurement Accuracy (1µA range FAST value) | Current accuracy: ±(2.0+(0.5µ/(measured current value)))% Resistance accuracy: current accuracy + voltage accuracy of external power supply |
| Test Voltage Setting | 0.1V~1000.0V (Resolution: 0.1V) |
| Contact check function | Judge the contact status by comparing it with the reference value judged by the measured capacity value. |
| Other Functions | Trigger delay, average value, contact check, fixture capacitance open circuit compensation, comparison and judgment of measured values, fixture open circuit compensation function, setup condition backup, LCD display light off/light on |
| connector | GP-IB, RS-232C, EXT I/O |
| Power Supply, Consumption | SM7810: AC 100V/110 V, 50/60 Hz, 30 VA SM7810-20: AC 220 V, 50/60 Hz, 30 VA |
| Volume and weight | 425 mm W × 99 mm H × 488 mm D, 10.5 kg |
| attachment (email) | Power cord × 1, Voltage input connector × 1, Spare fuse (in socket) × 1, Rubber base × 4, Instruction manual × 1 |