● Insulation resistance test (DC50V~1200V), withstand voltage test (AC/DC5000V), full remote control
:: Programmable tests (32 files for test programs, 50 steps per file for test points)
● Generate accurate test voltage by PWM control method.
● 3930 High Voltage Scanning Unit (option)
Pressure-resistant test section
| Output Voltage AC/DC | AC0.2~5.00kV,500VA(rated 30 minutes)/DC0.2~5.00kV,50VA(continuous) |
|---|---|
| Voltage setting method | Digital setting (setting resolution: 0.01kV) |
| AC Waveform/Frequency | Sine wave (distortion rate below 5% without load), switchable at 50/60Hz |
| Current measurement range | 10mA, resolution: 0.01mA / 100mA, resolution: 0.1mA |
| voltmeter | Accuracy: ±1.5%f.s. (JIS Class 1.5, f.s.=5.00kV) (RMS display) |
| Method of Determination | Window comparison method (digital setting) |
Insulation resistance test
| rated voltage | DC50~1200V (can be set arbitrarily if 1V step) |
|---|---|
| Rated test current | 1mA, short-circuit current: 200mA or less |
| Test range/accuracy | 0.10 to 9999 MΩ, 4 ranges, ±4 % rdg. (Representative value 0.5 MΩ to 1000 MΩ) |
| Method of Determination | Window comparison method (digital setting) |
Timer *The timer setting time will vary depending on the load during the actual test.
| Setting range | 0.3 to 999 s |
|---|---|
| Ramp/Delay | Test voltage Ramp up, down, insulation resistance test delay: 0.1 ~ 99.9s |
| functionality | Program up to 32 files with 50-step experimental settings Save 10 sets of test contents for voltage/insulation withstand each, hold, buzzer |
| monitoring function | Output voltage, detection current/test resistance, monitoring cycle: 2 times/s or more |
| power supply | AC100~120 V, 200~240 V (50/60 Hz), 1000 VA max. |
| Volume/Weight | 320W×155H×480D mm,18kg |
| attachment (email) | 9615 high-voltage test cable (high-voltage cable and loop, 1 each), power cord × 1, instruction manual × 1, spare fuse × 1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.