-Automatically determines AC and DC
-Up to DC 2000V for open-circuit voltage inspection of photovoltaic panels (*1)
-Simultaneous display of inrush current (INRUSH) RMS value and waveform peaks
-Wireless support! Measured values can be transferred to a smartphone or tablet device (when wireless adapter Z3210 is installed)
-Harmonic analysis from 1st to 30th harmonic through software GENNECT Cross (when wireless adapter Z3210 is installed)
Product Feature Name
※1 Requires option P2000, which can measure up to DC 1000V from the main unit alone.
CAT IV 600 V, CAT III 1000 V
(CAT III 2000 V, CAT IV 1000 V (when using P2000)
Basic parameters (accuracy guaranteed for 1 year, adjusted accuracy guaranteed for 1 year)
| DC current range | 20.00 A/600.0 A, basic accuracy: ±1.3% rdg. ±0.08 A (range 20A) |
|---|---|
| AC current range | 20.00 A/600.0 A (10 to 1 kHz, true RMS rectified), basic accuracy 45 - 66 Hz : ±1.3% rdg. ±0.08 A (at 20A) |
| crest factor | Range 20.00 A: 7.5 Range 600.0 A: 3 or less |
| AC + DC current range | 20.00 A/600.0 A (10 to 1 kHz, true RMS rectified), basic accuracy DC, 45 - 66 Hz : ±1.3% rdg. ±0.13 A (at 20A) |
| DC voltage range | 600.0 mV to 1000 V (600.0 V to 2000 V when using P2000) |
| AC Voltage Range | 6.000 V to 1000 V, 4 ranges (15 to 1 kHz, true RMS rectification), basic accuracy 45 - 66 Hz : ±0.9% rdg. ±0.003 V (at 6V) |
| AC + DC voltage range | 6.000 V to 1000 V, 4 ranges, basic accuracy DC, 45 - 66 Hz : ±1.0% rdg. ±0.013 V (at 6V) |
| Resistance range | 600.0 Ω to 6.000 MΩ, 5 ranges, basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω) |
| electrostatic capacitance range | 1.000 μF to 1000 μF, 4 ranges, basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF) |
| frequency range | 9.999 Hz to 999.9 Hz, 3 ranges, basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz) |
| Temperature (K) | -40.0 to 400.0 ˚C, Accuracy: ±0.5% rdg. ±3.0 ˚C + Temperature Probe Accuracy |
| a power test | Hi: AC40 V~600 V, Lo: AC80 V~600 V, 50/60 Hz |
| harmonic (wave with frequency an integer multiple of the fundamental) | Harmonic level/content/total harmonic distortion up to the 30th order in the current can be measured [when Z3210 is installed]. * :: Can be displayed using application software (GENNECT Cross) |
| Other Functions | DC power, conductivity check, diode check, AC/DC auto judgement function, DC current-voltage positive/negative judgement function, maximum/minimum/average/peak maximum/peak minimum display, low-pass filtering function, display value hold, backlight, auto power save, beep, zero adjustment, etc. |
| Dust and water resistance | IP20 (voltage measurement in completely dry condition, with jaws closed) IP54 (when stored) |
| power supply | Alkaline Battery No. 7 (LR03) × 2 Approx. 40h (when Z3210 is not installed), approx. 20h (when Z3210 is installed and wireless communication is performed) Other conditions: AC 10 A measurement, LCD backlight OFF, 23°C reference value |
| Measurable conductor diameter | φ33 mm, Jaw size: 69 W × 14 D mm |
| Volume and weight | 65 W × 215 H × 35 D mm, 340 g |
| attachment (email) | Test Lead L9300 ×1, Carrying Case C0203 ×1, Alkaline Battery No. 7 (LR03) ×2, Instruction Manual ×2, Precautions for Use ×1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.