Digital Multimeter DT4261
Digital Multimeter DT4261
Digital Multimeter DT4261
Digital Multimeter DT4261
Digital Multimeter DT4261
Digital Multimeter DT4261

Digital Multimeter DT4261

Powerful and versatile Harmonics can be measured
Dramatically improve failure analysis and work efficiency in the field

Categories. , Tag. Brand.

Inquire about this product

-Helps with failure analysis at the test site
-Improve work efficiency! Saving of measuring man-hours through electronic management (Excel® direct input function)
-Designed to prevent misplugging of test cables for safe and secure testing (terminal protection function)
-Integrated test lead and test sheath
-High dust and waterproof rating (IP54)

Product Feature Name

CAT III 1000V, CAT IV 600V

Basic parameters

Accuracy is guaranteed for 1 year.
※About the accuracy of the DMM: Since the digital multimeter has many measurement functions and ranges, the basic accuracy stated is only a representative value. For the accuracy of each range, please refer to the PDF of the product manual.

dc voltage 600.0 mV to 1000 V, 5 ranges, basic accuracy: ±0.15 % rdg. ±2 dgt.
AC Voltage 40~500Hz 6.000 V to 1000 V, 4 ranges, Frequency: 40 Hz to 1 kHz
Basic accuracy 40 Hz - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3 or less)
DC + AC Voltage 6.000 V~1000 V, 4 ranges, Frequency: DC,40 Hz~1 kHz
Basic accuracy DC, 40 Hz - 500 Hz : ±1.0 % rdg. ±13 dgt. (True RMS, crest factor 3 or less)
LoZ V 600.0 V, 1 range, Frequency: DC, 40 Hz ~ 1 kHz
Basic accuracy DC, 40 Hz - 500 Hz : ±1.0 % rdg. ±13 dgt. (True RMS, crest factor 3 or less)
resistive 600.0 Ω ~ 60.00 MΩ, 6 ranges, basic accuracy: ±0.7 % rdg. ±3 dgt.
direct current 600.0 mA to 10.00 A, 3 ranges, basic accuracy: ±0.5 % rdg. ±3 dgt.
alternating current (electricity) 600.0 mA to 10.00 A, 3 ranges, basic accuracy 40 Hz - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3 or less) Frequency
Characteristics: 40 Hz ~ 1 kHz
AC current (measured by AC clamp-on probe) 10.00 A to 1000 A, 7 ranges, basic accuracy 40 Hz - 500 Hz : ±0.9 % rdg. ±3 dgt. plus measurement accuracy of clamp-on probes
(True RMS, crest factor 3 or less)
capacitive coupling 1.000 μF to 10.00 mF, 5 ranges, basic accuracy: ±1.9 % rdg. ±5 dgt.
conductivity check Conductivity ON Threshold: 25 Ω, Conductivity OFF Threshold: 245 Ω, Response Time: 0.5 ms or more
Diode Testing Open Circuit Voltage: 2.0 V or less, Test Current: 0.2 mA, Clockwise Threshold: 0.15 V ~ 1.8 V
Voltage Frequency 99.99 Hz ~ 99.99 kHz, 4 ranges (depending on minimum sensitivity voltage)
Basic accuracy: ±0.1 % rdg. ±1 dgt.
current frequency 99.99 Hz to 9.999 kHz, 3 ranges (depending on minimum sensitivity current)
Basic accuracy: ±0.1 % rdg. ±1 dgt.
harmonic (wave with frequency an integer multiple of the fundamental) Harmonic level/content/total harmonic distortion up to the 30th order in the current can be measured [when Z3210 is installed].
* :: Can be displayed using application software (GENNECT Cross)
Other Functions Foolproof insertion prevention function, Fuse check function, User setting hold function, Filter function, Auto zero, Display value hold, Auto hold, Maximum/minimum value display, Transient value (PEAK) display, Auto power save, USB communication (only when the optional communication package DT4900-01 is installed), Wireless communication (only when the optional wireless adapter Z3210 is installed)
demonstrate 4-digit LCD, max. 6000 dgt. (except frequency measurement), bar graph
Display update rate 5 cycles/s (capacitive coupling: 0.05 to 5 cycles/s depending on measured value, frequency: 1 to 2 cycles/s)
power supply Alkaline dry batteries (LR6) × 3, Continuous use time: 130 h (without Z3210 installed), 70 h (with Z3210 installed, wireless communication)
Volume and weight 87W × 185H × 47D mm, 480 g (including test lead holder, battery)
attachment (email) Test Lead L9300 ×1, Instruction Manual ×1, Alkaline Dry Battery No. 5 (LR6) ×3, Precautions for Use ×1