Deep Storage, Fast Refresh
Adopting Ding Yang's original SPO technology, digital trigger system with high trigger sensitivity and low jitter.
256 levels of luminance and color temperature display for greater clarity
Waveform refresh rate of 400,000 wfm/s for easy capture of abnormal waveforms
14 Mpts storage depth for in-depth view of waveform details
256 levels of luminance and color temperature display for greater clarity
Waveform refresh rate of 400,000 wfm/s for easy capture of abnormal waveforms
14 Mpts storage depth for in-depth view of waveform details


A revolution in data analysis and processing
14 M full sampling point measurement, measurement accuracy and sampling accuracy are exactly the same, no distortion
14 M full sample point operation, additional co-processor to complete, faster
1 M-point FFT operation, support Peaks, Markers, FFT points optional
Support for Zoom, Gating, Math measurements and statistics
Supports 38 automatic measurement functions
Hardware-accelerated computing for a smoother user experience
14 M full sample point operation, additional co-processor to complete, faster
1 M-point FFT operation, support Peaks, Markers, FFT points optional
Support for Zoom, Gating, Math measurements and statistics
Supports 38 automatic measurement functions
Hardware-accelerated computing for a smoother user experience


Power Loop Response Analysis / Potentiogram (4-channel series only)
Stability is a very important indicator in power supply design. Generally speaking, stability measurement needs to use a special frequency response analyzer, but because of its high price is often prohibitive, so DYNAM provides a set of economical solutions: DYNAM SDS1000X-E oscilloscope and signal source with the standard free Bode Plot Ⅱ software, to achieve the power loop measurement.
- Newly developed baud plot measurement core for higher measurement sensitivity and accuracy
- Variable excitation scanning modes for power control loop test boxes and other complex test scenarios
- Humanized UI design, more friendly parameter settings
- Tabular and cursor measurements for more intuitive analysis of results


Serial decoding is standard
Most of the oscilloscopes on the market do not come standard with serial CAN, LIN, I2C, SPI, RS-232/UART bus triggering and decoding functions, and you need to purchase additional options to open this function. The SDS1000X-E product should be born in response to the needs of engineers, this function as standard, free of charge.
Waveforms and data can be displayed on the interface at the same time, which is convenient to view; the detailed information of decoding is displayed in the form of a list, and it supports storing and exporting the data.


Powerful debugging and analysis capabilities
Event search and navigation to quickly locate events of interest
MSO Logic Analyzer Integration, Mixed Signal Analyzer
Combination of historical and sequential modes, no hiding of abnormal signals
Hardware-based Pass/Fail mode for long-term signal monitoring
MSO Logic Analyzer Integration, Mixed Signal Analyzer
Combination of historical and sequential modes, no hiding of abnormal signals
Hardware-based Pass/Fail mode for long-term signal monitoring
Remote control via web page
With the embedded Web Server, you can remotely control the instrument, observe the waveforms and get the measurement results through the browser without installing the driver software and the host computer software, which can meet the application requirements of high voltage, high temperature and other special environments. The embedded virtual control panel is exactly the same as the oscilloscope panel, which is easier and more convenient to use. SDS1000X-E supports two styles of web page layouts for PC and cell phone, so that control and observation can be easily accomplished on cell phone as well.

model number | analog bandwidth | channel number | Maximum real-time sampling rate | Maximum waveform capture rate | Maximum storage depth | Reference price (including tax) |
---|---|---|---|---|---|---|
SDS1204X-E | 200 MHz | 4 | 1 GSa/s | 400,000 wfm/s | 14 Mpts | ¥5,680 |
SDS1202X-E | 200 MHz | 2 + EXT | 1 GSa/s | 400,000 wfm/s | 14 Mpts | ¥4,380 |
SDS1104X-E | 100 MHz | 4 | 1 GSa/s | 400,000 wfm/s | 14 Mpts | ¥5,280 |
SDS1102X-E | 100 MHz | 2 + EXT | 1 GSa/s | 400,000 wfm/s | 14 Mpts | ¥3,780 |
SDS1074X-E | 70 MHz | 4 | 1 GSa/s | 400,000 wfm/s | 14 Mpts | ¥4,880 |
SDS1072X-E | 70 MHz | 2 + EXT | 1 GSa/s | 400,000 wfm/s | 14 Mpts | ¥3,480 |
Specification | |||
---|---|---|---|
bandwidths | 70 MHz, 100 MHz, 200 MHz | Decoding type (standard) | ic, spi, uart/rs232, can, lin |
real time sampling rate | The 2-channel series adopts one 1 GSa/s ADC chip and the 4-channel series adopts two 1 GSa/s ADC chips, with a sampling rate of 500 MSa/s per channel when all channels are on, and a sampling rate of 1 GSa/s in channel interleaving mode. | 16-channel logic analyzer (4-channel series optional) | Maximum sample rate 1 GSa/s, storage depth 14 Mpts/CH |
channel number | 4 (4-channel series) | Portmap (4-channel series support) | Minimum Start Frequency 10 Hz, Minimum Sweep Width 500 Hz, Maximum Sweep Width 120 MHz (and limited by current model bandwidth and source bandwidth), Maximum Sweep 500 Frequency Points |
2+EXT (2-channel series) | connector | USB Host, USB Device, Sbus (4-channel series support, Siglent logic analyzer interface), LAN, Pass/Fail, Trigger Out | |
Storage depth | Channel interleaved mode 14 Mpts/CH, non-interleaved mode 7 Mpts/CH | Standard Probes | 4 Sets / 2 Sets Passive Probes PB470 |
Maximum waveform capture rate | 400,000 wfm/s (Sequence mode) | 4 sets / 2 sets of passive probes PP510 | |
Trigger Type | Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Serial Trigger (IIC, SPI, UART, CAN, LIN) | 4 sets / 2 sets of passive probes PP215 | |
USB Arbitrary Waveform Generator (4-channel series option) | Single channel, maximum output frequency 25 MHz, sampling rate 125 MSa/s, waveform length 16 kpts | screen (TV, computer or movie) | 7-inch TFT-LCD display with 800*480 resolution |
weights | 2-channel series: net weight 2.5 kg; gross weight 3.5 kg | ||
4-channel series: net weight 2.6 kg; gross weight 3.8 kg |