GPM-8213 Power Meter
GPM-8213 Power Meter
GPM-8213 Power Meter
GPM-8213 Power Meter

GPM-8213 Power Meter

  • 4" TFT LCD display
  • Two numerical display modes
  • Standard screen: Display 2 primary measurement items + 6 secondary measurement items
  • Simple screen: shows the values of the 4 main tests.
  • Meets the requirements of IEC 62301 for power measurement.
  • Voltage/current test bandwidth up to DC~6kHz
  • Watt resolution up to 1uW
  • Minimum current level 5mA, resolution up to 0.1uA
  • Current/voltage can be measured up to distortion waveforms with a CF of 3, with a half range CF of 6.
  • Wh power time/Ah current time integration function
  • With total harmonic distortion measurement
  • With front panel test terminals
  • Standard Interface: RS-232C, USB device, LAN
  • Optional Interface: GPIB (must be factory installed)
  • Options: GPM-001

Categories. , Tags. , Brand.

Inquire about this product

GPM-8213 is a digital power meter designed for single-phase (1P/2W) AC power measurement. The product adopts 4" TFT LCD display, 5-digit quantitative display, provides 19 kinds of parameters related to power measurement, integral measurement function, and highly accurate voltage/current/power measurement capability, front/rear panel input terminals, various communication interfaces...etc., to assist the user to achieve clear, convenient and accurate power measurement. Measurement

The GPM-8213 provides up to 19 parameters for power measurement, including Voltage (Vrms/ V+pk/ V-pk), Current (Irms/ I+pk/ I-pk), Frequency (VHz/ IHz), Power (P/ P+pk/ P-pk), Crest Factor (CFV/ CFI), Visible Power (VA), and Void Power (VAR), Power Factor (PF), Phase Angle (DEG), Total Harmonic Distortion Rate (THDV/ THDI), and highly accurate voltage/current/power measurement (±0.1% readings ±0.1% gears); and properly utilize the advantages of the TFT LCD display, in addition to a simple mode to present the same four parameters as the traditional power meter. In addition to the same four measurement parameters as the traditional power meter, the TFT LCD display can even display 8 measurement parameters (2 main measurements + 6 monitoring measurements), which not only meets the need for accuracy and easy readability in process testing, but also meets the needs of R&D, design and quality verification of a wide range of measurement applications.

The GPM-8213 is designed to meet the requirements of IEC 62301/EN 50564 standby power consumption measurements for products under test. The GPM-8213 also provides measurement support, including a test bandwidth of up to DC~6kHz, support for small currents up to 5mA (with a resolution of up to 0.1uA), a power measurement resolution of up to 1uW, a crest factor of up to 3 (with a half range of up to 6), and a total harmonic distortion rate (at least 13th order). Total harmonic distortion (at least 13th order power harmonics) can be measured. For large voltage/current measurement applications, the PT/CT rate function can be used with an external Potential Transformer or Current Transformer to meet the measurement requirements.

In addition, in terms of data acquisition and storage, in addition to the standard RS-232C/USB interface (virtual COM)/LAN for programming and reading, there is also an optional GPIB interface (to be installed at the factory), which meets the habits of the majority of people who use automatic measurement systems.

GPM-8213 AC/DC Digital Power Meter Introductionhttps://v.youku.com/v_show/id_XNDYyMTc4NzcyMA==.html

 

Quick Selection

model number demonstrate gear level (i.e. first gear, high gear etc) Standby power consumption test Standard Interface
GPM-8213 4-inch TFT LCD 600V/20A YES USB/RS-232/LAN

 

 

Detailed specifications                                                                           
Measurement characteristics
importation
sports event gear level (i.e. first gear, high gear etc)
Input Voltage 600 Vrms
Input Current 20 Arms
Input impedance (50/60 Hz) input voltage 2.4MΩ
  amps 5mA - 200mA: 500mΩ
  amps 0.5A - 20A: 5mΩ
Maximum display voltage 700 Vrms
Maximum display current 25 Arms
Maximum permissible insulation voltage 300 V
Low Frequency Filters cut-off frequency 500 Hz
parameters
synchronization frequency 45Hz ~ 6kHz
Average number of times 1, 2, 4, 8, 16, 32, 64
Display items (standard mode) 8 projects (simultaneous)
Display items (simple mode) 4 projects (simultaneous)
Number of Display Bits 5
Voltage converter (PT ratio) 1 ~ 9999.999
Current converter (CT ratio) 1 ~ 9999.999
Measurement items Voltage, Current, Effective Power, Apparent Power, Ineffective Power, Power Factor, Phase Angle, Frequency, Integral Current, Integral Power, Positive Integral Power, Negative Integral Power, Integral Time, Voltage Waveform Factor, Current Waveform Factor, Peak Voltage, Peak Current, Total Harmonic Distortion
Measurement Display Symbols Vdc, Vrms, V+pk, V-pk, Idc, Irms, I+pk, I-pk, P, P+pk, P-pk, VA, VAR, PF, CFV, CFI, DEG, VHz, IHz, THDV, THDI
 Voltage measurement
measuring gear CF=3 15v, 30v, 60v, 150v, 300v, 600v
  CF=6 7.5v, 15v, 30v, 75v, 150v, 300v
wave factor 3, 6
accuracy range of validity Gear of 1 % ~ 105 %
  DC ±(0.2 % reading + 0.2 % stop)
  45 Hz ≤ f ≤ 66 Hz ±(0.1 % reading + 0.1 % stop)
  66 Hz < f ≤ 1kHz ±(0.1 % reading + 0.2 % stop)
  1 kHz < f ≤ 6kHz ± 3 % gears
  Filter on Increased error 0.3 % reading @ 45Hz to 66Hz
temperature effect 5-18˚C / 28-40˚C Increase ±0.03% reading /˚C
residual noise 0.5 % gear
current measurement
measuring gear CF=3 5mA, 10mA, 20mA, 50mA, 100mA, 200mA, 500mA, 1A, 2A, 5A, 10A, 20A
  CF=6 2.5mA, 5mA, 10mA, 25mA, 50mA, 100mA, 250mA, 0.5A, 1A, 2.5A, 5A, 10A
wave factor 3, 6
accuracy range of validity Gear of 1 % ~ 105 %
  DC ±(0.2 % reading + 0.2 % stop)
  45 Hz ≤ f ≤ 66 Hz ±(0.1 % reading + 0.1 % stop)
  66 Hz < f ≤ 1kHz ±(0.1 % reading + 0.2 % stop)
  1 kHz < f ≤ 6kHz ± 3 % gears
  Filter on Increased error 0.3 % reading @ 45Hz to 66Hz
temperature effect 5-18˚C / 28-40˚C Increase ±0.03% reading /˚C
residual noise 0.5 % gear
power measurement
accuracy range of validity Gear of 1 % ~ 110 %
  DC ±(0.2 % reading + 0.2 % stop)
  45 Hz ≤ f ≤ 66 Hz ±(0.1 % reading + 0.1 % stop)
  66 Hz < f ≤ 1kHz ±(0.1 % reading + 0.3 % stop)
  1 kHz < f ≤ 6kHz ± 3 % gears
  Filter on. Increased error 0.3 % reading @ 45Hz to 66Hz
temperature effect 5-18˚C / 28-40˚C Increase ±0.03% reading /˚C
Frequency measurement
Measurement range Filter on 30.000Hz to 499.99Hz
  Filter off 30.000Hz to 9.9999kHz
Measurement items Voltage, current
Effective Input Range Input Voltage File Bit 10% ~ 105%
accuracy ± (0.06 % reading)
integral measurement
integrator accuracy ± (voltage or current accuracy + 0.1 % reading)
timers realm 0 hours 0 minutes ~ 9999 hours 59 minutes
  accuracy ±0.01% ±1 sec.
General Information
storage state Temperature -40°C ~ 70°C; Humidity < 90%RH (non-condensing)
Using the power supply AC 100-240V, 50-60Hz; Power consumption 25VA(max)
Size and Weight 270(W) x 110(H) x 350(D) mm, approx. 2.9 kg

Standard Accessories
Safety Guide x 1
Power cord x 1
Test Lead GTL-209 x 1
CD-ROM x 1 (with full manual and USB driver)

Optional equipment
Option 01 GPIB Card
Note: Optional GBIP must be factory installed prior to shipment.

Optional Accessories
GPM-001 Test Fixture Box (with cable)
GTL-232 RS-232C cable, 9-pin Female to 9-pin, null modem for computer, approx. 2000mm
GTL-246 USB cable, A-B type, approx. 1200mm
GTL-248 GPIB cable, approx. 2000mm
GTL-251 GPIB-USB-HS+ (high speed)

 

Ordering Information

GPM-8213 with GPIB Digital Power Meter (with RS-232C / USB device / LAN and optional interface GPIB)

GPM-8213 Digital Power Meter (with RS-232C / USB device / LAN)

Expand More
GPM-8213 Power MeterGPM-8213 Power Meter

Click to enquire