Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302

Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302

Product Features
  • Test frequency 20Hz~200kHz/1MHz, accuracy 0.02%
  • Basic measurement accuracy: 0.1%
  • Three impedance output modes to choose from, and the measurement results are fully comparable with the LCR meters of well-known brands.
  • Enhanced Turn Ratio for accurate measurement of low permeability cores.
  • High-speed LCR measurement, up to 80 times/sec.
  • High-speed DCR measurement, up to 50 times/sec.
  • Graphical and tabular displays are available for scanning frequency, voltage and overlap current measurements (3252/3302).
  • Built-in 8mA reset current for RJ45 transmission transformer environment (optional, pre-shipment installation only)
  • For TV Inverter transformers, 100Bin leakage classification and leakage balancing are provided.
  • ALC (Automatic Location Compensation) function for MLCC (Multilayer Ceramic Electrolytic Capacitor) measurement (3252/3302)
  • Provide fixture stray capacity compensation function for transformer and inductor measurement.
  • 1320 DC Overlap Current Source Direct Control Power (3252/3302)
  • Large LCD display (320 x 240 dot matrix)
  • Provide all kinds of standard test fixtures and special fixtures customized.
  • Four-terminal test fixtures for accurate and stable measurement of DCR, inductance and turn ratio.
  • Built-in comparator: 10 levels of bin sorting and counting (3252/3302)
  • Inductance measurement as leakage inductance center value for transformer applications in chargers.
  • 4M SRAM memory card for machine data setup and backup
  • Standard RS232, HANDLER, PRINTER interface, support LCR function GPIB interface (optional)
  • 15 internal instrument settings to store and call

Category. Tag. Brand.

Inquire about this product

Chroma 3250/3252/3302 transformer test system, for a transformer production or QC incoming and outgoing inspection, with high stability and high reliability of the precision measurement instruments. 3250/3252 provide 20Hz-200kHz test frequency, 3302 provides 20Hz-1MHz test frequency. The transformer scanning test program covers all kinds of transformer low-voltage measurement parameters. Including inductance, leakage inductance, turn ratio, DC resistance, impedance, coil-to-coil capacity and other primary parameters; quality factor, series equivalent resistance and other secondary parameters, as well as short-circuit inspection. High-speed digital sampling technology and scanning test fixture (A132501) design, so that the previous time-consuming and inefficient transformer production inspection becomes accurate and fast.

The 3250/3252/3302 also provide a variety of output impedance modes for selection, making it possible to solve the problem of inductance difference caused by the difference in test current between test instruments due to the difference in test output impedance. In addition, the inductance conversion method is provided in the turn ratio measurement technique, which can improve the turn ratio measurement error caused by high leakage ratio of low coupling coefficient transformers.

In addition to the transformer scanning function, the 3252/3302 also provides the LCR Meter function, which can be applied to various parts for incoming and outgoing inspection, R&D analysis or production line automation applications.

model number relate (a story or information)
3250 Automatic Transformer Test System
3250 Automatic transformer test system (with 8mA overlap current)
3252 Automatic Parts Analyzer
3252 Automatic Parts Analyzer (with GPIB interface)
3302 Automatic Parts Analyzer
3302 Automatic Parts Analyzer (with GPIB interface)
3302 Automatic Parts Analyzer (with 8mA overlap current)
3302 Automatic Parts Analyzer (Transformerless Scanning Test)
A110211 Component Test Kit
A110211 Component Test Kit
A110212 Component Remote Test Box
A110234 High Frequency Test Lines
A110239 Four-terminal SMD Electrolytic Capacitor Test Kit
A113012 Vacuum generator (for use with A132574)
A113014 Vacuum mercury pump (for use with A132574)
A132501 Transformer Auto Scan Test Kit
A132563 WINCPK Transformer Test Data Statistical Analysis Software (USB Software Protector)
A132574 SMD Power Choke Test Fixture
A133004 SMD Test Boxes
A133019 BNC test lead 2M (one side open)
A133006 1A overlapping current source device
Expand More
Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302Automatic Transformer Test System/Automatic Parts Analyzer Model 3250/3252/3302

Click to enquire

Product consultation and purchase:18218718851

I already understand