HCPX8000 Series Current ProbesIt is a high frequency current probe capable of measuring both DC and AC. Its features include: high bandwidth, high accuracy.With the intelligent probe controller, the probe can communicate with most of the mainstream brands of oscilloscopes on the market, and automatically set the attenuation ratio, impedance, delay time and so on. It solves the long-term difficulties of using third-party general-purpose oscilloscope probes that must be set manually, realizes the same user experience as oscilloscope dedicated interface probes, and is not limited by a single brand of oscilloscope.If the intelligent control function is not required, the customer can also be powered directly by an adapter (It is not possible to use the USB port of the oscilloscope to supply power to the probe.) for current measurements.

Product Electrical Specifications

tweezers

Model No. HCPX8030(C/D/H) HCPX8050 HCPX8070
Bandwidth (-3dB) HCPX8030 DC-50MHz (Figure 1.a) DC-50MHz

(Figure 4)

DC-30MHz

(Figure 7)

HCPX8030C DC-70MHz (Figure 1.b)
HCPX8030D DC-100MHz (Figure 1.c)
HCPX8030H DC-120MHz (Figure 1.d)
rising time HCPX8030 ≤7ns ≤7ns ≤11.6ns
HCPX8030C ≤5ns
HCPX8030D ≤3.5ns
HCPX8030H ≤2.92ns
continuous current

maximum values

HCPX8030 30 Arms (Figure 2.a) 50 Arms

(Figure 5)

70 Arms

(Figure 8)

HCPX8030C 30 Arms (Figure 2.b)
HCPX8030D 30 Arms (Figure 2.c)
HCPX8030H 30 Arms (Figure 2.d)
peak current 50Apk 75Apk 100Apk
range (of scales or measuring equipment) 5A 1X attenuation 7.5A 1X attenuation 10A 2X attenuation
30A 10X attenuation 50A 10X attenuation 70A 20X attenuation
Overcurrent alarm value 5A ≥5APk 7.5A ≥7.5APk 10A ≥10APk
30A ≥50APk 50A ≥75APk 70A ≥100APk
Current Transfer Ratio 5A 1V/A 7.5A 1V/A 10A 0.5V/A
30A 0.1V/A 50A 0.1V/A 70A 0.05V/A
resolution (of a photo) 5A 1mA 7.5A 1mA 10A 2mA
30A 10mA 50A 10mA 70A 20mA
accurate

(DC, 45-66Hz max continuous current)

5A ±1%±1mA 7.5A ±1%±1mA 10A ±1%±2mA
30A ±1%±10mA 50A ±1%±10mA 70A ±1%±20mA
Input Impedance HCPX8030 Reference figure (3.a) Reference (Figure 6) Reference (Figure 9)
HCPX8030C Reference figure (3.b)
HCPX8030D Reference figure (3.c)
HCPX8030H Reference figure (3.d)
Time delay (probe main unit)

+1m BNC)

Reference (Figure 19)
Terminal Load Requirements ≥100kΩ
Power supply method DC 5V/2A (standard adapter)
Insulated line voltage 300V CAT I
Safety meets standards EN61010-1: 2010+A1:2019 en 61010-2-032:2019
EMC Compliance en61326-1:2013 en61000-3-2:2014 en61000-3-3:2013