{"id":12210,"date":"2025-02-17T09:27:51","date_gmt":"2025-02-17T01:27:51","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/12210.html"},"modified":"2025-02-17T09:29:56","modified_gmt":"2025-02-17T01:29:56","slug":"%e9%ab%98%e9%a2%91%e7%bd%97%e6%b0%8f%e7%ba%bf%e5%9c%88-cphx9000b%e7%b3%bb%e5%88%97","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/12210.html","title":{"rendered":"High Frequency Rochester Coils CPHX9000B Series"},"content":{"rendered":"<p><strong>\u00a0<\/strong><strong>Electrical Specifications<\/strong><\/p>\n<p><strong>Measurement conditions: 23\u00b0C; 60%RH; the wire under test passes through the center of the probe's induction loop. \u00a0\u00a0\u00a0<\/strong><\/p>\n<p><strong>\u00a0\u00a0\u00a0<\/strong><\/p>\n<table class=\"table table-bordered table-striped\" width=\"750\" cellspacing=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"157\"><strong>model number<\/strong><\/td>\n<td valign=\"center\" width=\"101\"><strong>CPH<\/strong><strong>X<\/strong><strong>9012<\/strong><strong>B<\/strong><\/td>\n<td valign=\"center\" width=\"103\"><strong>CPH<\/strong><strong>X<\/strong><strong>9030<\/strong><strong>B<\/strong><\/td>\n<td valign=\"center\" width=\"99\"><strong>CPH<\/strong><strong>X<\/strong><strong>9060<\/strong><strong>B<\/strong><\/td>\n<td valign=\"center\" width=\"97\"><strong>CPHX9120B<\/strong><\/td>\n<td valign=\"center\" width=\"95\"><strong>CPHX9300B<\/strong><\/td>\n<td valign=\"center\" width=\"98\"><strong>CPHX9600B<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>current range<\/strong><\/td>\n<td valign=\"center\" width=\"101\">120Apk<\/td>\n<td valign=\"center\" width=\"103\">300Apk<\/td>\n<td valign=\"center\" width=\"99\">600Apk<\/td>\n<td valign=\"center\" width=\"97\">1200Apk<\/td>\n<td valign=\"center\" width=\"95\">3000 Apk<\/td>\n<td valign=\"center\" width=\"98\">6000 Apk<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>Range Sensitivity<\/strong><\/td>\n<td valign=\"center\" width=\"101\">10mV\/A<\/td>\n<td valign=\"center\" width=\"103\">5mV\/A<\/td>\n<td valign=\"center\" width=\"99\">2mV\/A<\/td>\n<td valign=\"center\" width=\"97\">1mV\/A<\/td>\n<td valign=\"center\" width=\"95\">0.5mV\/A<\/td>\n<td valign=\"center\" width=\"98\">0.2mV\/A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>Typical Accuracy<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\">\u00b12%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>High Frequency Bandwidth<\/strong><strong>(<\/strong><strong>-3dB<\/strong><strong>)<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\"><strong>22<\/strong><strong>0MHz<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>rising time<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\">\u2264 1.59ns<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>Low Frequency Cutoff (Hz)<\/strong><\/td>\n<td valign=\"center\" width=\"101\">65<\/td>\n<td valign=\"center\" width=\"103\">32<\/td>\n<td valign=\"center\" width=\"99\">15<\/td>\n<td valign=\"center\" width=\"97\">7.2<\/td>\n<td valign=\"center\" width=\"95\">3.5<\/td>\n<td valign=\"center\" width=\"98\">1.5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>di\/dt (kA\/us)<\/strong><\/td>\n<td valign=\"center\" width=\"101\">65<\/td>\n<td valign=\"center\" width=\"103\">185<\/td>\n<td valign=\"center\" width=\"99\">328<\/td>\n<td valign=\"center\" width=\"97\">650<\/td>\n<td valign=\"center\" width=\"95\">1850<\/td>\n<td valign=\"center\" width=\"98\">3280<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>output noise<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\">1.8mVrms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>Output Impedance<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\">50\u03a9<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>output interface<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\">BNC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>Maximum Output Voltage<\/strong><\/td>\n<td valign=\"center\" width=\"101\">\u00b11.2Vpk<\/td>\n<td valign=\"center\" width=\"103\">\u00b11.5Vpk<\/td>\n<td valign=\"center\" width=\"99\">\u00b11.2Vpk<\/td>\n<td valign=\"center\" width=\"97\">\u00b11.2Vpk<\/td>\n<td valign=\"center\" width=\"95\">\u00b11.5Vpk<\/td>\n<td valign=\"center\" width=\"98\">\u00b11.2Vpk<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\"><strong>Power supply method<\/strong><\/td>\n<td colspan=\"6\" valign=\"center\" width=\"593\">USB 5V\/2A (standard adapter)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p><strong>CPH<\/strong><strong>X<\/strong><strong>9000<\/strong><strong>A\/B<\/strong><strong>Series Roche Coil High Frequency<\/strong><strong>amps<\/strong><strong>extend one's head (out or into)<\/strong>It's a test.<strong>AC Current Signal<\/strong>High-frequency current probes with high bandwidth and high accuracy (2% typical).<strong>The probes have a communication function and can be used with the intelligent probe controller OT7001.<\/strong><strong>Real-time control of the oscilloscope to set the product model and voltage of the smart probe accessed by the user<\/strong><strong>amps<\/strong><strong>type, attenuation ratio, delay and other parameters. Completely solved the long-term user to use a third-party oscilloscope probe must be manually set the probe parameters of the difficulties, realize and<\/strong><strong>Oscilloscope Dedicated Interface<\/strong><strong>Probe-like user experience.<\/strong>Bandwidth up to<strong>22<\/strong><strong>0MHz<\/strong>Withstand voltages up to<strong>1kVpk<\/strong>The standard BNC output interface makes it easy to connect with oscilloscopes, data collectors, etc. to observe current waveforms; 4 No.5 batteries or external USB DC5V power supply makes it more flexible and convenient to use; the length of the probe ring and connecting wires can be customized according to the customer's requirements to meet the requirements of special occasions for testing.<\/p>","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[3541],"product_cat":[1998,52],"product_tag":[],"class_list":{"0":"post-12210","1":"product","2":"type-product","3":"status-publish","5":"product_brand-cybertke","6":"product_cat-current-probes","7":"product_cat-tydzcs","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-variable"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/12210","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=12210"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=12210"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=12210"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=12210"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=12210"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}