{"id":13532,"date":"2025-02-24T14:11:56","date_gmt":"2025-02-24T06:11:56","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/13532.html"},"modified":"2025-02-25T16:10:11","modified_gmt":"2025-02-25T08:10:11","slug":"%e5%a4%8d%e5%88%b6-%e5%a4%8d%e5%88%b6-2","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/13532.html","title":{"rendered":"Fluke 190 Series III ScopeMeter\u00ae Test Tool"},"content":{"rendered":"<h2>Product Overview: Fluke 190 Series III ScopeMeter\u00ae Test Tool<\/h2>\n<div id=\"overview-grid\">\n<div id=\"fluke-product-display-overview\">\n<div id=\"overview_content\">\n<h3>High-performance portable oscilloscope designed for harsh environments<\/h3>\n<p>Designed for use in a variety of locations, the Fluke 190 Series III ScopeMeter\u00ae Test Tools are ready to tackle any troubleshooting job. These CAT III 1000 V\/CAT IV 600V-rated test tools combine rugged portability with high-performance benchtop oscilloscopes to help you easily meet the challenges of installing, commissioning, and maintaining industrial machinery, automation\/process control devices, and power conversion electronics from DC to 500 MHz.<\/p>\n<p>Choose from dual- or quad-channel models with a wide range of bandwidth options. Fast sampling rates up to 5.0 GS\/s with 200 ps resolution and deep memory for 10,000 samples per channel allow waveform details, noise and other disturbances to be captured and displayed with high accuracy. Make timing or amplitude-dependent measurements on three-phase or three-axis control systems, or compare and contrast multiple test points on the circuit under test. features such as TrendPlot\u2122 paperless recorder, ScopeRecord\u2122 mode, Connect-and-View\u2122 triggering, and a unique 100-screen replay function help you diagnose problems quickly, minimizing maintenance costs and downtime. costs and downtime. These features make the oscilloscope easy to use, especially when diagnosing the most difficult problems, such as complex waveforms, induced noise, intermittent events, and signal fluctuations or drift.<\/p>\n<ul>\n<li>Up to four independent floating isolated inputs up to 1000 V<\/li>\n<li>Up to 5 GS\/s real-time sample rate (depending on model and channel used)<\/li>\n<li>Deep memory: 10,000 points per waveform trace capture (oscilloscope mode)<\/li>\n<li>CAT III 1000 V\/CAT IV 600 V safety instruments for industrial environments<\/li>\n<li>Up to seven hours of battery life thanks to the BP291 battery<\/li>\n<li>Bright, large color display that is easy to view in almost any environment<\/li>\n<li>Easy to store and view historical data and transfer to PC via USB or Wifi<\/li>\n<li>Easy-open and close battery cover for quick battery changes in the field<\/li>\n<li>Dust and water resistant to IP51<\/li>\n<li>Connect-and-View triggering for fast, slow, and even complex signals.<\/li>\n<li>Spectrum analysis using FFT<\/li>\n<li>100-screen automatic capture and replay<\/li>\n<li>ScopeRecord mode provides 30,000 points per input channel for low-frequency signal analysis<\/li>\n<li>TrendPlot paperless recorder mode with deep memory for long-term automated measurements<\/li>\n<li>5,000 count multimeter (DMM) included in 2-channel model<\/li>\n<\/ul>\n<div class=\"container-flex\">\n<div><img decoding=\"async\" class=\"img-responsive lazyloaded\" title=\"\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/F-190-504-series%203_08a_w.jpg\" alt=\"\" \/><\/div>\n<div>\n<h3>Safe measurement of mV to kV voltage<\/h3>\n<p>Separate isolated inputs allow you to make measurements on mixed circuits with different ground references, reducing the risk of accidental short circuits. Conventional benchtop oscilloscopes are not equipped with specialized differential probes and isolation transformers, and can only use the line power ground as the measurement reference. The Fluke 190III Oscilloscope Test Set is designed to cover a wide range of applications from mV to kV, so you can tackle anything from microelectronic applications to heavy-duty, high-voltage electrical applications. 190III 60 MHz and 100 MHz configurations include the VPS421 100:1 Probe for high-voltage applications, while 200 MHz and 500 MHz configurations include the VPS421 100:1 Probe for microelectronic and high-voltage applications. The 200MHz and 500MHz configurations include the VPS410-II 10:1 probe for microelectronics and high voltage applications.<\/p>\n<h3>IP-51 rating for harsh environments<\/h3>\n<p>The Oscilloscope Test Kit is rugged and vibration resistant for use in dirty, hazardous environments. Comes with a sealed case that protects against dust, liquid droplets, moisture and airborne contamination. You can rest assured that every time you test with your oscilloscope, it will reliably solve any problem you may have.<\/p>\n<h3>USB and Wi-Fi connectivity<\/h3>\n<p>The Fluke 190 Series III provides two USB ports electrically isolated from the measurement input circuitry, which allows you to quickly and easily transfer data to a PC, archive and share waveforms with OEMs, coworkers, and support personnel, or store waveforms, screenshots, and instrument settings on a USB memory device for future use. Saved files are easily transferred via USB flash drive, which connects directly to the PC via the USB port or optional Wi-Fi network. These files can be used for further data processing or in FlukeView-2 software to study the waveforms in more detail.<\/p>\n<\/div>\n<\/div>\n<div class=\"container-flex col-reverse\">\n<div>\n<h3>Connect-and-View Trigger Functions<\/h3>\n<p>Connect-and-View triggering provides an instant, stable display with no need to adjust settings. If you've ever worked with other oscilloscopes, you know how tricky triggering can be. If you don't set it up correctly, results can be erratic or incorrect, and the Connect-and-View feature automatically sets the correct trigger by recognizing signal patterns. Without touching a button, you can display almost any signal, including motor drive and control signals, consistently, reliably, and reproducibly. This is especially fast and convenient when you are measuring a series of test points quickly and continuously.<\/p>\n<\/div>\n<div><img decoding=\"async\" class=\"img-responsive lazyloaded\" title=\"Connect and View feature captures the most complex signals without additional setups\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/AUTO-2__Image5675a.png\" alt=\"Connect and View feature captures the most complex signals without additional setups\" \/><\/div>\n<\/div>\n<div class=\"container-flex\">\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15803\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Image053.png\" width=\"1124\" height=\"769\" alt=\"Image053\" title=\"Image053\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Image053.png 1124w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Image053-300x205.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Image053-800x547.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Image053-1024x701.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Image053-768x525.jpg 768w\" sizes=\"auto, (max-width: 1124px) 100vw, 1124px\" \/><\/div>\n<div>\n<h3>Built-in digital multimeter<\/h3>\n<p>Use the built-in 5000-word digital multimeter on the dual-channel 190III model to make it easy to switch from waveform analysis to accurate multimeter measurements. Measurement functions include Vdc, Vac, Vac+dc, resistance, on-off and diode tests. Combine the right shunt, probe or adapter with a variety of scale factors to measure current and temperature.<\/p>\n<\/div>\n<\/div>\n<div class=\"container-flex col-reverse\">\n<div>\n<h3>ScopeRecord\u2122 mode for recording high-resolution waveforms<\/h3>\n<p>The ScopeRecord memory stores up to 30,000 or more data points per channel and captures fast intermittent events and short-duration pulse wave disturbances as short as 8 ns. (Two sets of multi-channel recordings can be stored in memory for later analysis. (Two sets of multi-channel records can be stored in memory for later analysis.)<\/p>\n<ul>\n<li>Record events such as UPS, power supply or motor start cycles<\/li>\n<li>ScopeMeter Test Tool automatically recognizes power failures and stores pre-failure waveform data thanks to the \"Stop on Trigger\" mode.<\/li>\n<\/ul>\n<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15804\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/ScopeRecord_Zoom-x2.png\" width=\"1124\" height=\"769\" alt=\"ScopeRecord_Zoom-x2\" title=\"ScopeRecord_Zoom-x2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/ScopeRecord_Zoom-x2.png 1124w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/ScopeRecord_Zoom-x2-300x205.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/ScopeRecord_Zoom-x2-800x547.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/ScopeRecord_Zoom-x2-1024x701.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/ScopeRecord_Zoom-x2-768x525.jpg 768w\" sizes=\"auto, (max-width: 1124px) 100vw, 1124px\" \/><\/div>\n<\/div>\n<div class=\"container-flex\">\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15802\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Trend-Plot-2.png\" width=\"1124\" height=\"769\" alt=\"Trend-Plot-2\" title=\"Trend-Plot-2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Trend-Plot-2.png 1124w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Trend-Plot-2-300x205.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Trend-Plot-2-800x547.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Trend-Plot-2-1024x701.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Trend-Plot-2-768x525.png 768w\" sizes=\"auto, (max-width: 1124px) 100vw, 1124px\" \/><\/div>\n<div>\n<h3>TrendPlot paperless logger - up to 11 days of logging to help you find intermittent faults<\/h3>\n<p>The most difficult faults to find are those that occur occasionally. These intermittent events can be caused by improper connections, dust, dirt, corrosion, broken wires, or broken connectors. Line interruptions, dips, surges and momentary breaks, or motor starts and stops may also cause downtime. You may not be around when these conditions occur, but the Fluke 190 Series III ScopeMeter Test Tool will help you monitor them at all times.<\/p>\n<ul>\n<li>Display of minimum and maximum peaks and average values over time<\/li>\n<li>Displays any combination of up to four readings including voltage, current, temperature, frequency and phase for all inputs, all time and date stamped to identify faults<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"container-flex col-reverse\">\n<div>\n<h3>FlukeView2 software for recording, archiving and analyzing<\/h3>\n<p>Learn more about the ScopeMeter Test Tool with FlukeView 2 ScopeMeter software for Windows.<\/p>\n<ul>\n<li>Recording - transfer waveforms, screenshots and data to a PC for printing or importing data into reports<\/li>\n<li>Adds text to ScopeMeter Test Tool settings - provides guidance to operators when recalling settings<\/li>\n<li>Archiving - create waveform libraries for easy reference or comparison of waveforms<\/li>\n<li>Analysis - use cursor functions or export data to another analysis program<\/li>\n<\/ul>\n<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15806\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/FV2-3.png\" width=\"1401\" height=\"732\" alt=\"FV2-3\" title=\"FV2-3\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/FV2-3.png 1401w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/FV2-3-300x157.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/FV2-3-800x418.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/FV2-3-1024x535.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/FV2-3-768x401.png 768w\" sizes=\"auto, (max-width: 1401px) 100vw, 1401px\" \/><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<h2 class=\"features-title\">Main characteristics<\/h2>\n<div id=\"keyfeature_content\">\n<ul>\n<li>For CAT III 1000 V\/CAT IV 600 V industrial environments<\/li>\n<li>Automatically capture, display and analyze complex waveforms<\/li>\n<li>Bright, large color display for easy on-site viewing<\/li>\n<li>USB and Wi-Fi downloads to analyze data using FlukeView\u00ae software<\/li>\n<li>Up to four independent floating isolated inputs up to 1000 V<\/li>\n<\/ul>\n<\/div>","protected":false},"featured_media":13826,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[3528],"product_cat":[3927],"product_tag":[],"class_list":{"0":"post-13532","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-fluke","7":"product_cat-scopemeter","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/13532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=13532"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/13826"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=13532"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=13532"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=13532"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=13532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}