{"id":13674,"date":"2025-02-25T09:53:57","date_gmt":"2025-02-25T01:53:57","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/13674.html"},"modified":"2025-02-27T17:04:57","modified_gmt":"2025-02-27T09:04:57","slug":"%e5%a4%8d%e5%88%b6-%e5%a4%8d%e5%88%b6-%e5%a4%8d%e5%88%b6-%e5%a4%8d%e5%88%b6-%e5%a4%8d%e5%88%b6-%e5%a4%8d%e5%88%b6-6","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/13674.html","title":{"rendered":"Fluke 773 Milliamp Process Clamp Meter"},"content":{"rendered":"<h2>Product Overview: Fluke 773 Milliamp Process Clamp Meter<\/h2>\n<div id=\"overview-grid\">\n<div id=\"fluke-product-display-overview\">\n<div id=\"overview_content\">\n<p><strong>Need more time?<\/strong><\/p>\n<p>No need to disconnect the circuit when performing 4-20 mA signal measurements and saves time.<\/p>\n<p><strong>Are you spending valuable time?<\/strong><\/p>\n<ul>\n<li>Perform mA measurements by removing wiring and disconnecting circuits<\/li>\n<li>Calling the control room to isolate the circuit<\/li>\n<li>Testing analog inputs\/outputs on the console<\/li>\n<li>Troubleshooting devices with mA inputs and outputs<\/li>\n<li>Troubleshooting 4-20 mA circuits that have intermittent problems or are unstable<\/li>\n<li>Return to Workshop for additional tools<\/li>\n<\/ul>\n<p>If you are always busy and never have enough time, try the Fluke 773 milliamp clamp meter. These clamp meters save you time and money by eliminating the need to perform time-wasting activities. Now you can diagnose and repair 4-20 mA circuits without having to disconnect the loop or shut down the system.<\/p>\n<p>Here are some ways the Fluke 773 Clamp Meter can help you:<\/p>\n<table>\n<tbody>\n<tr class=\"bodybold\">\n<td><strong>Milliamp Clamp Meter Features<\/strong><\/td>\n<td><strong>appliance<\/strong><\/td>\n<td><strong>How to save time and money<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Measure mA signals from analog I\/O of PLCs and control systems without disconnecting the loop.<\/td>\n<td>Measurement of weak direct current<\/td>\n<td>Correlate process indications with real physical values<\/td>\n<\/tr>\n<tr>\n<td>Measurement of the output signal of the transmitter without disconnecting the loop<\/td>\n<td>Maintenance and diagnostics of process and automation equipment without having to disconnect the circuits<\/td>\n<td>No interruption to the process<\/td>\n<\/tr>\n<tr>\n<td>Detachable clamp meter with extension cable<\/td>\n<td>Performs measurements in tight spaces<\/td>\n<td>Allows measurements to be made in a variety of difficult situations<\/td>\n<\/tr>\n<tr>\n<td>Outputs, mA signals in analog and measurement circuits (open loop)<\/td>\n<td>Confirm non-contact measurements. Have spare tools on hand for troubleshooting (signal source analog)<\/td>\n<td>Troubleshooting without having to return to the workshop to obtain a loop calibrator after finding the defective signal through non-contact measurements<\/td>\n<\/tr>\n<tr>\n<td>Outputs and measures VDC signal sources<\/td>\n<td>Troubleshoot voltage input and output devices.<\/td>\n<td>Measures the presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signal.<br \/>\nTest Chart Recorder<\/td>\n<\/tr>\n<tr>\n<td>4 to 20 mA input\/output<\/td>\n<td>Dual-channel mA Source and Measurement for Troubleshooting<\/td>\n<td>Transmit a 4 to 20 mA signal to the valve and mA signal conditioner and then synchronize the measurement of the 4 to 20 mA bit-controlled output signal.<\/td>\n<\/tr>\n<tr>\n<td>4 to 20 mA proportional output<\/td>\n<td>The proportional mA output provides a mA signal output to indicate the measured mA value.<\/td>\n<td>Connection of a digital multi-meter (DMM) with logging\/graphing function and logging of mA signals without having to disconnect the loop<\/td>\n<\/tr>\n<tr>\n<td>Provide circuit power<\/td>\n<td>Power supply for conveyors<\/td>\n<td>Replacement test for an installed 24V loop power supply. Supplies power to the transmitter and measures its mA output signal for troubleshooting.<\/td>\n<\/tr>\n<tr>\n<td>Dual backlit display showing mA measured value and percentage of 4-20 mA range<\/td>\n<td>Clear measurement display<\/td>\n<td>Allows rapid measurement evaluation<\/td>\n<\/tr>\n<tr>\n<td>Measuring Spotlights<\/td>\n<td>Illuminates hard-to-find wiring in dark enclosures<\/td>\n<td>Easier and faster measurement process<\/td>\n<\/tr>\n<tr>\n<td>Measures up to 99.9 mA of current in a non-contact manner<\/td>\n<td>Wide range<\/td>\n<td>Measurement of 10 to 50 mA signals in old control systems<\/td>\n<\/tr>\n<tr>\n<td>Automatic power off<\/td>\n<td>Automatically turns off backlight and spotlight after 15 minutes and 2 minutes<\/td>\n<td>Extended battery life<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<h2 class=\"features-title\">Main characteristics<\/h2>\n<div id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\">\n<p><strong>Fluke 773 mA Clamp Meter Features.<\/strong><\/p>\n<ul>\n<li>Better 0.2% accuracy<\/li>\n<li>0.01 mA Resolution and Sensitivity<\/li>\n<li>Measurement of 4 to 20 mA signals without \"breaking the loop<\/li>\n<li>Measurement of mA signals of analog I\/O of PLCs and control systems<\/li>\n<li>Dual backlit display showing mA measured value and percentage of 4 to 20 mA range<\/li>\n<li>Measuring spotlight illuminates hard-to-find wiring in dark chassis<\/li>\n<li>Detachable clamp meter with extension cord for measurements in tight spaces<\/li>\n<li>Measurement of 10 to 50 mA signals in old control systems using 99.9 mA range<\/li>\n<li>Automatically changes 4 to 20 mA output for remote testing<\/li>\n<li>Power-saving features such as auto shut-off and backlight timeout extend battery life<\/li>\n<li>\"Hold function captures and displays changing measurements<\/li>\n<li>Measurement of 4 to 20 mA signals by means of the \"Meter Pen\" access loop measurement function<\/li>\n<li>Synchronized 24V loop power supply and measurement of loop mA signals to power and test transmissions<\/li>\n<li>Outputs a 4 to 20 mA signal source to test control system I\/O or I\/P.<\/li>\n<li>mA Output Linear Fade or 25% Step Output<\/li>\n<li>Automatically changes 4 to 20 mA output for remote testing<\/li>\n<li>DC voltage measurement to verify 24V power or voltage I\/O signals<\/li>\n<li>Provides a DC voltage source to test input devices that can accept 1-5V or 0 to 10V signals<\/li>\n<li>The proportional mA output provides a continuous mA signal corresponding to the 4 to 20 mA signal measured by the mA clamp meter.<\/li>\n<li>Milliampere signals can be recorded to a separate recording device without disconnecting the loop<\/li>\n<li>Output mA signal allows logging digital multi-meters or other devices to record 4 to 20 mA signals without disconnecting the loop<\/li>\n<li>mA Input\/Output: Measure mA signals non-breakingly with a clamp meter and output mA signal source<\/li>\n<li>Apply the mA input signal to a device and then measure its 4-20 mA output on a device such as a valve or mA isolator<\/li>\n<li>Voltage Output Linear Fading or 25% Step Outputs<\/li>\n<li>Automatically changes voltage output for remote testing<\/li>\n<\/ul>\n<\/div>","protected":false},"featured_media":14879,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[3528],"product_cat":[3973],"product_tag":[],"class_list":{"0":"post-13674","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-fluke","7":"product_cat-loop-calibrator","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/13674","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=13674"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/14879"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=13674"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=13674"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=13674"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=13674"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}