{"id":2190,"date":"2024-11-30T14:46:40","date_gmt":"2024-11-30T06:46:40","guid":{"rendered":"https:\/\/www.wbyq.cn\/?post_type=product&#038;p=2190"},"modified":"2025-01-03T15:18:54","modified_gmt":"2025-01-03T07:18:54","slug":"it6000b%e7%b3%bb%e5%88%97%e5%9b%9e%e9%a6%88%e5%bc%8f%e6%ba%90%e8%bd%bd%e7%b3%bb%e7%bb%9f","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/2190.html","title":{"rendered":"IT6000B Series Feedback Source Load System"},"content":{"rendered":"<div class=\"Pbox3\">\n<div class=\"product_info_floor3 product_info_floor33\">\n<div class=\"container\">\n<h2 class=\"product_info_ptitle\">Product Features<\/h2>\n<div class=\"i\"><\/div>\n<div class=\"product_info_floor3_lr\">\n<p>\u2666 Adopt SiC technology, one machine for two purposes, bi-directional power supply and feed-back loads combined in one unit<\/p>\n<p>\u2666 One-touch switching of source loads in the panel<\/p>\n<p>High power density, up to 18kW in 3U, expandable to 2MW in parallel<br \/>\nVoltage output range: 0 to 2250V<br \/>\nCurrent output range: 0 to 2040A (single cabinet), 0 to 8000A (parallel connection between cabinets)<br \/>\n\u2666 Bidirectional energy transfer, seamless switching across quadrants<br \/>\n\u2666 Support control loop priority mode setting, set different loop speeds<br \/>\n\u2666 Built-in LV123, LV148, DIN40839, ISO-16750-2, SAEJ1113-11, LV124 and ISO21848 standard voltage curves for automotive power grids<br \/>\n\u2666 Energy Return Nearly 95%<br \/>\n\u2666 Can be used as a PV simulator (with SAS1000), supporting the simulation of solar cell matrix I-V curves.<\/p>\n<p>It can be used as a battery simulator (with BSS2000 software) to simulate the characteristic curve of LiFePO4\/LiT3 battery.<\/p>\n<p>Battery cycle test, support CC\/CV\/CP and other battery charging\/discharging modes.<br \/>\n\u2666 Built-in function generator, support arbitrary waveform generation<br \/>\nAdjustable output impedance<\/p>\n<p>\u2666 Multiple protection functions, support OVP, \u00b1 OCP, \u00b1 OPP, OTP, power-down, islanding protection<br \/>\n\u2666 Built-in USB\/CAN\/LAN\/Digital IO interface, optional GPIB\/Analog &amp; RS232<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"Pbox4\">\n<div class=\"product_info_floor3 product_info_floor44\">\n<div class=\"container\">\n<h2 class=\"product_info_ptitle\">Product Features and Benefits<\/h2>\n<div class=\"i\"><\/div>\n<h3 class=\"product_info_floor3_lr\">Source-loaded functions One-touch switching<\/h3>\n<p>The IT6000B series incorporates 2 devices, a bi-directional DC power supply and an energy-feedback DC load. The user-friendly design of the function keys on the panel makes it easy for users to use the IT6000B as a bi-directional programmable DC power supply or as an energy-feedback DC electronic load. For users to save the space occupied by the equipment, cost and time spent on connecting the instrument to be measured.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20082\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211728202820.jpg\" width=\"775\" height=\"343\" alt=\"201811211728202820\" title=\"201811211728202820\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211728202820.jpg 775w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211728202820-300x133.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211728202820-768x340.jpg 768w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211728202820-600x266.jpg 600w\" sizes=\"auto, (max-width: 775px) 100vw, 775px\" \/><\/p>\n<p>Bi-directional energy for seamless switching<\/p>\n<p>The IT6000B series combines the functional features of a bi-directional power supply and a feed-back load in one unit. Unlike traditional power supplies and loads that have short jumps and discontinuities when switching between positive and negative currents, the IT6000B series, as a standard high-speed bi-directional power supply, realizes high-speed switching between source and load current modes, which enables fast, continuous, and seamless switching between output and absorbed currents, effectively avoiding overshoots in voltage or current, and is widely used in testing of energy storage devices, such as batteries, battery packages, and battery protection boards. It is widely used for battery, battery package, and battery protection board testing.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20083\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20190722172106216.png\" width=\"709\" height=\"482\" alt=\"20190722172106216\" title=\"20190722172106216\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20190722172106216.png 709w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20190722172106216-300x204.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20190722172106216-600x408.png 600w\" sizes=\"auto, (max-width: 709px) 100vw, 709px\" \/><\/p>\n<p>High energy recovery efficiency<\/p>\n<p>The IT6000B series has an energy recovery function, which can recover electrical energy and then utilize it directly in the plant instead of consuming it in the form of heat energy. Its conversion efficiency can be close to 95%, which not only greatly reduces the user's electricity cost, but also avoids the use of air-conditioning or expensive refrigeration systems and reduces noise. Most of the ordinary electronic loads are energy-consuming loads, in addition to the high cost of electricity, the power generation process will also produce a large amount of carbon dioxide, sulfur dioxide, nitrogen oxides and other greenhouse gases or harmful gases, causing harm to the environment. Using the IT6000B series can reduce electricity consumption, which not only saves money, but also reduces the emission of greenhouse gases and harmful gases.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20084\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20210701150252252.jpg\" width=\"1136\" height=\"322\" alt=\"20210701150252252\" title=\"20210701150252252\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20210701150252252.jpg 1136w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20210701150252252-300x85.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20210701150252252-800x227.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20210701150252252-1024x290.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20210701150252252-768x218.jpg 768w\" sizes=\"auto, (max-width: 1136px) 100vw, 1136px\" \/><\/p>\n<p>Solar Array Analog Power Applications<\/p>\n<p>IT6000B series is equipped with SAS1000 solar cell matrix simulation software, which can simulate the I-V curve of solar cell matrix, and the built-in SAS model of EN50530, Sandia, NB\/T32004, CGC\/GF004, CGC\/GF035, users can simulate the output of the I-V curve and generate a report by simple parameter setting, which can be used to testing the static and dynamic maximum power tracking effectiveness of PV inverters. Users can also edit any I-V curve with up to 4096 points to realize the dynamic cloud shading effect, or store 100 I-V curves under different light and temperature in the memory, and set the execution time and sequence of each curve to test the long-time maximum power tracking performance of the PV inverter under different climate conditions.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20085\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211733393339.jpg\" width=\"1170\" height=\"399\" alt=\"201811211733393339\" title=\"201811211733393339\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211733393339.jpg 1170w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211733393339-300x102.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211733393339-800x273.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211733393339-1024x349.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211733393339-768x262.jpg 768w\" sizes=\"auto, (max-width: 1170px) 100vw, 1170px\" \/><\/p>\n<p>Built-in a variety of standard automotive test curves<\/p>\n<p>Automotive electronic equipment may often encounter power transient interference during vehicle startup and operation. To ensure that the device under test can withstand these real-world transients, users need to simulate the worst-case power transient conditions during testing. According to the relevant industry standards IT6000B series built-in LV123, LV148, DIN40839, ISO-16750-2, SAEJ1113-11, LV124 and ISO21848 standard automotive power network voltage curves, the user can be directly retrieved from the automotive start-up instantaneous voltage dips and a variety of automotive electronic test pulse waveforms related to automotive electronics performance testing. Users can directly retrieve the voltage drop at the moment of automobile startup and many kinds of automobile electronic test pulse waveforms to test the performance of related automobile electronic products, with 12V, 24V and 48V voltage levels available.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20093\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143.png\" width=\"1905\" height=\"1052\" alt=\"20200515131403143\" title=\"20200515131403143\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143.png 1905w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143-300x166.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143-800x442.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143-1024x565.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143-768x424.png 768w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20200515131403143-1536x848.png 1536w\" sizes=\"auto, (max-width: 1905px) 100vw, 1905px\" \/><\/p>\n<p>CC&amp;CV Prioritization Function<\/p>\n<p>The IT6000B series continues ITECH's CC\/CV prioritization concept, which continues to help users solve various severe problems in long-term test applications, and makes applications requiring high-speed or overshoot-free power supply more flexible. Users can select the CC\/CV loop response speed and loop operation mode to determine whether the output is in voltage high speed mode or current no overshoot mode, which is suitable for applications such as high power IC testing, charge\/discharge testing, and power transient simulation and characterization in automotive electronics.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20086\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20181121173904394.jpg\" width=\"1117\" height=\"451\" alt=\"20181121173904394\" title=\"20181121173904394\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20181121173904394.jpg 1117w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20181121173904394-300x121.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20181121173904394-800x323.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20181121173904394-1024x413.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/20181121173904394-768x310.jpg 768w\" sizes=\"auto, (max-width: 1117px) 100vw, 1117px\" \/><\/p>\n<p>Parallel technology<\/p>\n<p>Same performance parameters as stand-alone machine after parallel operation<\/p>\n<p>The system does not need to be calibrated after parallel operation.<\/p>\n<p>Parallel machine adopts fiber optic transmission, which has strong anti-interference ability.<\/p>\n<div>\n<div>Adoption of digital parallel scheme, fiber optic full isolation, effective protection of equipment and objects to be measured<\/div>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20088\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211741504150.jpg\" width=\"1181\" height=\"548\" alt=\"201811211741504150\" title=\"201811211741504150\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211741504150.jpg 1181w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211741504150-300x139.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211741504150-800x371.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211741504150-1024x475.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211741504150-768x356.jpg 768w\" sizes=\"auto, (max-width: 1181px) 100vw, 1181px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20087\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211742324232.jpg\" width=\"1227\" height=\"531\" alt=\"201811211742324232\" title=\"201811211742324232\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211742324232.jpg 1227w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211742324232-300x130.jpg 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211742324232-800x346.jpg 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211742324232-1024x443.jpg 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2024\/11\/201811211742324232-768x332.jpg 768w\" sizes=\"auto, (max-width: 1227px) 100vw, 1227px\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<div>The IT6000B series adopts SiC technology to integrate the bi-directional power supply and feed-back load into a single instrument with only 3U volume. A single button allows it to switch freely between bi-directional power supply and feed-back load, not only can it be used as an independent bi-directional power supply to realize the function of source and provide power; it can also be used as an independent feed-back load, which not only absorbs power but also returns the consumed energy cleanly to the power grid, with the standard dual-quadrant function.<\/div>\n<div>IT6000B series can be up to 2250 V. Utilizing the master-slave mode to support parallel connection, active equalization, the power can be extended to 2MW. built-in function generator, you can freely generate arbitrary waveforms, and through the USB interface to import the LIST file to generate the waveforms. IT6000B series are widely used in high-power batteries, automotive electronics, green energy, high-speed testing, etc., and are a series of products with rich features and excellent performance. feature-rich, high-performance and widely applicable product series.<\/div>","protected":false},"featured_media":2481,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[52,67],"product_tag":[1862,1860,1857,1856,1859,1861],"class_list":{"0":"post-2190","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-tydzcs","7":"product_cat-dc-electronic-loads","8":"product_tag-battery-cycle","9":"product_tag-1860","10":"product_tag-1857","11":"product_tag-1856","12":"product_tag-1859","13":"product_tag-1861","15":"first","16":"instock","17":"shipping-taxable","18":"purchasable","19":"product-type-variable","20":"has-default-attributes"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/2190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=2190"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/2481"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=2190"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=2190"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=2190"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=2190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}