{"id":23577,"date":"2025-06-26T17:53:58","date_gmt":"2025-06-26T09:53:58","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/23577.html"},"modified":"2025-07-12T15:36:20","modified_gmt":"2025-07-12T07:36:20","slug":"%e9%ab%98%e9%a2%91%e4%ba%a4%e7%9b%b4%e6%b5%81%e7%94%b5%e6%b5%81%e6%8e%a2%e5%a4%b4cp%e7%b3%bb%e5%88%97","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/23577.html","title":{"rendered":"High Frequency AC\/DC Current Probe CP Series"},"content":{"rendered":"<h2>Products<\/h2>\n<p>Micsig (Micsig) high-frequency AC and DC current probe CP series, bandwidth up to 100MHz, continuous current 30A and 50A peak current, accuracy up to 1%, resolution up to 1mA, 5A \/ 30A dual-range design, can accurately capture the current waveform, provide high-precision measurement results, is committed to optimizing product design for engineers. The jaws are only 5mm in diameter, easy to use, demagnetization and auto-zeroing can be done with one key operation, over-current alarm design, reminding range switching, standard BNC interface design, applicable to all brands of oscilloscopes.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/1_1741072696.png\" \/><\/p>\n<h2>Measurement of high frequency current signals<\/h2>\n<p>The high-frequency AC and DC current probes are still comfortable for measuring signals above 20M. (CH1 yellow waveform in the figure)<\/p>\n<p>And the signal has been completely distorted when the low-frequency AC\/DC current probe measures the same this signal. (CH2 blue waveform in the figure)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/5_1731640817.png\" alt=\"High Frequency Current Probes\" \/><\/p>\n<h2>Observed surge current<\/h2>\n<p>Capable of accurately capturing the inrush current waveform during power adapter startup.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/6_1731640826.png\" alt=\"High Frequency Current Probes\" \/><\/p>\n<h2>Excellent design<\/h2>\n<p>One key auto zero + demagnetization, simple and efficient operation, faster and more accurate measurement<\/p>\n<p>Over-current alarm design (corresponding to the range indicator flashes), to remind the range switching, to ensure the safety of the test<\/p>\n<p>Adopts standard BNC interface design, applicable to all brands of oscilloscopes<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/CP%E7%B3%BB%E5%88%97_CP%E7%B3%BB%E5%88%97_1741600560.png\" alt=\"McKesson High Frequency AC and DC Current Probes\" \/><\/p>\n<h2>Compact and refined appearance<\/h2>\n<p>Only 5mm jaw diameter to meet the test requirements of compact and small boards<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/a_1717666624.png\" alt=\"McKesson High Frequency Current Probes\" \/><\/p>\n<div class=\"img\">\n<div class=\"picture_container\"><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/CP_1740126272.png\" alt=\"High frequency AC and DC current probe applications\" \/><\/div>\n<\/div>\n<div class=\"txt_box flex flex_row_center flex_column\">\n<div class=\"con\">\n<h2>Application Areas<\/h2>\n<p>New Energy Vehicle Design<\/p>\n<p>Switching Power Supply Design<\/p>\n<p>Electrotechnical experiments<\/p>\n<p>Semiconductor Device Design<\/p>\n<p>Avionics design<\/p>\n<p>Inverter \/ Transformer Design<\/p>\n<p>Electronic ballast design<\/p>\n<p>Industrial Control \/ Consumer Electronics Design<\/p>\n<p>Engine drive unit design<\/p>\n<p>Power Electronics and Power Drives Experiment Design<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.micsig.com.cn\/uploads\/CP_1740126272.png\" alt=\"High frequency AC and DC current probe applications\" \/><\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong>High Frequency AC\/DC Current Probe<\/strong><strong>CP Series<\/strong><\/p>\n<p>Bandwidth: DC-50MHz \/ DC-100MHz<\/p>\n<p>Maximum measuring current: 50Apk, 30Arms<\/p>\n<p>Typical Accuracy: 1%<\/p>\n<p>Dual range design: 5A\/30A<\/p>\n<p>Jaw diameter: 5mm<\/p>\n<p>Interface: Standard BNC<\/p>","protected":false},"featured_media":23426,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[4520],"product_cat":[4527],"product_tag":[],"class_list":{"0":"post-23577","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-micsig","7":"product_cat-current-probes-micsig","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-variable","14":"has-default-attributes"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/23577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=23577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/23426"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=23577"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=23577"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=23577"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=23577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}