{"id":9619,"date":"2025-02-06T10:03:23","date_gmt":"2025-02-06T02:03:23","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/9619.html"},"modified":"2025-02-13T19:27:59","modified_gmt":"2025-02-13T11:27:59","slug":"%e5%8f%af%e7%bc%96%e7%a8%8b%e7%9b%b4%e6%b5%81%e7%94%b5%e5%ad%90%e8%b4%9f%e8%bd%bdmodel-63600-series","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/9619.html","title":{"rendered":"Programmable DC Electronic Load Model 63600 Series"},"content":{"rendered":"<p>The 63600 series DC electronic loads are mainly used for the testing of A\/D power supplies, D\/D converters, chargers, batteries, server power supplies, and some power electronic components, etc. In addition, for R&amp;D departments, mass production, and some incoming material inspection applications, the 63600 can show its excellent performance.<\/p>\n<p>The 63600 utilizes new DSP technology to develop the first Constant Zero Impedance (CZ) mode of operation, which simulates the actual pulling condition of non-linear loads. 63600 series can pull its rated current at a low voltage (0.6V). This feature retains its optimal pull-down capability for Point-of-Load D\/D testing and fuel cell testing.<\/p>\n<p>The 63600 series can simulate a wide range of dynamic load applications with programmable pull current alignment, current creepage\/decrease, duration, and Von point voltage, etc. The 63600 series also has an automatic frequency sweep function (i.e., load simulation at different frequencies) to meet the needs of ATX power supplies. The 63600 also provides a 100-group memory that can be called upon at any time to recall the user's stored setpoints. In automated testing, this storage and call function can shorten the testing time.<\/p>\n<p>The 63600 integrates real-time accurate voltage and current measurement with three file bits per module and up to 16-bit resolution. Users can do real-time voltage measurement and adjustment online, or use the front panel buttons to perform short-circuit simulation tests. The 63600 series electronic loads can be easily operated and set up through the front panel OLED display and knobs, and can be remotely controlled through Ethernet, USB, and GPIB interfaces. 63600 also includes routine self-diagnostic functions and over-power, over-current, over-temperature protections and over-voltage alarms, as well as positive and negative reverse polarity alarms, which provide comprehensive protection to ensure that the 63600 series loads can be operated and adjusted online, and can be short-circuit simulated using the front panel buttons. This full range of protection features ensures the quality and reliability of the 63600 series.<\/p>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Product Applications<\/strong><\/h2>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17305\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_1.png\" width=\"1359\" height=\"600\" alt=\"Chroma_Page_63600_1\" title=\"Chroma_Page_63600_1\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_1.png 1359w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_1-300x132.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_1-800x353.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_1-1024x452.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_1-768x339.png 768w\" sizes=\"auto, (max-width: 1359px) 100vw, 1359px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16782\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_2.png\" width=\"1490\" height=\"883\" alt=\"Chroma_Page_63600_2\" title=\"Chroma_Page_63600_2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_2.png 1490w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_2-300x178.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_2-800x474.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_2-1024x607.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_2-768x455.png 768w\" sizes=\"auto, (max-width: 1490px) 100vw, 1490px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16785\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_3-SC.png\" width=\"1350\" height=\"439\" alt=\"Chroma_Page_63600_3-SC\" title=\"Chroma_Page_63600_3-SC\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_3-SC.png 1350w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_3-SC-300x98.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_3-SC-800x260.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_3-SC-1024x333.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_3-SC-768x250.png 768w\" sizes=\"auto, (max-width: 1350px) 100vw, 1350px\" \/><\/p>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Multi-functional system structure<\/strong><\/h2>\n<\/div>\n<p>Chroma's 63600 series of programmable electronic loads incorporate a digital signal microprocessor (200MHz) in each module, allowing for optimized speed and control performance when multiple modules are used. All modules can be operated individually or remotely. Simultaneous pull tests can be performed to simulate real-world pull conditions under multi-module conditions.<\/p>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>modular design<\/strong><\/h2>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-8 col-12\">\n<p>The modular design allows users to match any module of the same series with different needs. The mainframe 63600-5 can provide up to 10 channels of 100W when equipped with five 63610 modules, and up to 2kW when connected in parallel with five 63640 modules. In addition, when five 63640 modules are connected in parallel, the pulling capacity can be as high as 2kW. 63600's high pulling capacity makes it an excellent choice for testing multi-output switching power supplies and other power products. In addition, GO\/NG determination, in the automated test line, can immediately determine the product Pass or Fail, and the GPIB address is shared among five modules, which is conducive to synchronization, fast module control and readback of operational data.<\/p>\n<\/div>\n<div class=\"col-lg-4 col-12\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17301\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_4.png\" width=\"521\" height=\"347\" alt=\"Chroma_Page_63600_4\" title=\"Chroma_Page_63600_4\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_4.png 521w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_4-300x200.png 300w\" sizes=\"auto, (max-width: 521px) 100vw, 521px\" \/><\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Load Simulation Applications<\/strong><\/h2>\n<\/div>\n<p>The 63600 series has constant voltage, constant current, constant resistance, constant power, and constant impedance modes of operation to meet a wide range of test requirements. For example, the constant voltage mode can be used for battery charger charging test.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-3 col-12\">\n<p>Constant current mode<\/p>\n<p><img decoding=\"async\" class=\"img-fluid\" src=\"https:\/\/www.chroma.com.cn\/Upload\/images\/Products\/Power\/63600\/2024\/Chroma_Page_63600_5-1.png\" alt=\"\" \/><br \/>\n<strong>Constant current applications:<\/strong><\/p>\n<ol>\n<li>Load Modulation Test for Power Supplies<\/li>\n<li>Battery Discharge Time Test and Life Cycle Test<\/li>\n<li>Fuel Cell Testing<\/li>\n<li>Analog wiper pull current<\/li>\n<\/ol>\n<\/div>\n<div class=\"col-lg-3 col-12\">\n<p>Constant Resistance Mode<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16783\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_5-2.png\" width=\"240\" height=\"161\" alt=\"Chroma_Page_63600_5-2\" title=\"Chroma_Page_63600_5-2\" \/><br \/>\n<strong>Constant Resistance Application:<\/strong><\/p>\n<ol>\n<li>Test the current limit point, current climb rate and current drop rate of the current supply.<\/li>\n<li>Telecom Power Supply of Slow Start Test<\/li>\n<li>Simulation of automotive temperature controller for pull-load scenario<\/li>\n<\/ol>\n<\/div>\n<div class=\"col-lg-3 col-12\">\n<p>Constant Voltage Mode<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17297\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_5-3.png\" width=\"239\" height=\"160\" alt=\"Chroma_Page_63600_5-3\" title=\"Chroma_Page_63600_5-3\" \/><br \/>\n<strong>Constant voltage applications:<\/strong><\/p>\n<ol>\n<li>Cell Phone Charger Test<\/li>\n<li>Current Limit Test for Fold back Power Supplies<\/li>\n<li>Fuel Cell Testing<\/li>\n<li>Current Source Testing<\/li>\n<\/ol>\n<\/div>\n<div class=\"col-lg-3 col-12\">\n<p>Constant Power Mode<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17298\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_5-4.png\" width=\"240\" height=\"160\" alt=\"Chroma_Page_63600_5-4\" title=\"Chroma_Page_63600_5-4\" \/><br \/>\n<strong>Constant power applications:<\/strong><\/p>\n<ol>\n<li>Constant Power Supply Testing<\/li>\n<li>Battery capacity test and capacity life cycle test<\/li>\n<li>Pout v.s. Eff% curve test<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Precision Measurement<\/strong><\/h2>\n<\/div>\n<p>The 63600 series offers three load operating ranges with built-in 16-bit high-precision A\/D converters that measure voltage 0.025%+0.01%F.S., current 0.05%+0.05%F.S., and power 0.1%+0.1%F.S. The 63600 series is designed to meet the requirements of ENERGY STAR\u00ae and 80 Plus standards for measuring efficiency and other important parameters. S. The high accuracy is essential for measuring efficiency and other important parameters of the object under test, and the measurement accuracy also meets the requirements of ENERGY STAR\u00ae and 80 Plus.<\/p>\n<p>In addition to high-precision measurement, the 63600 series can also measure the voltage and current of overcurrent protection and overload protection. In addition, the 63600 series also provides users with the ability to set the step current for overcurrent protection testing, and determine the test result as Pass or Fail on the stand-alone machine, and the maximum power value (Pmax) during the test process can also be captured and displayed on the monitor automatically. The maximum power value (Pmax) during the test can be automatically captured and displayed on the display.<\/p>\n<p>In addition to high measurement accuracy, the 63600 series also has two built-in high-speed A\/Ds that can simultaneously measure voltage and current and calculate the actual power value so that the displayed power value is not distorted.<\/p>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Constant Impedance Mode (CZ Mode)<\/strong><\/h2>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p>Unique Constant Impedance pull mode is different from Constant Current and Constant Power pull mode, Constant Impedance mode simulates the actual inductive impedance, impedance, capacitive impedance, and load to pull load, therefore, the pull current is closer to the real situation. The following waveforms simulate the voltage and current waveforms of a switching power supply under capacitive load.<\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16788\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_6.png\" width=\"957\" height=\"438\" alt=\"Chroma_Page_63600_6\" title=\"Chroma_Page_63600_6\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_6.png 957w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_6-300x137.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_6-800x366.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_6-768x351.png 768w\" sizes=\"auto, (max-width: 957px) 100vw, 957px\" \/><\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Programmable Load Timing Function<\/strong><\/h2>\n<\/div>\n<p>The 63600 series has 100 built-in programmable load timings that allow the user to simulate a variety of different real-world pulling conditions. In addition, each module can be operated independently or synchronously, so each module can execute its own timing independently and start pulling loads together synchronously. The following are examples of common programmable timing applications.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16784\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_7.png\" width=\"599\" height=\"286\" alt=\"Chroma_Page_63600_7\" title=\"Chroma_Page_63600_7\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_7.png 599w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_7-300x143.png 300w\" sizes=\"auto, (max-width: 599px) 100vw, 599px\" \/><br \/>\nBattery discharge and other applications (laptop computers, electric vehicles and electric locomotives), simulate a variety of different real-world pull current waveforms, i.e., provide dynamic current simulation or one shot pull simulation with more than two current qubits.<br \/>\n(DUT for single channel output)<\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17299\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8.png\" width=\"553\" height=\"294\" alt=\"Chroma_Page_63600_8\" title=\"Chroma_Page_63600_8\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8.png 553w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8-300x159.png 300w\" sizes=\"auto, (max-width: 553px) 100vw, 553px\" \/><br \/>\nPrinter power supply tested at peak power cycle.<br \/>\n(DUT for three-channel output)<\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Dynamic Load and Control<\/strong><\/h2>\n<\/div>\n<p>In the fast era, electronic components are designed for high-speed operation, so the performance requirements of power components for transient signals and dynamic response are much higher than in the past. To meet these test applications and requirements, the 63600 series offers high speed, programmable dynamic loads, and dynamic frequency sweep sweep mode.<\/p>\n<p>The following figure shows the programmable parameters: set current high\/low alignment, T1\/T2, climb rate\/descent rate and number of executions.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16786\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_9.png\" width=\"600\" height=\"195\" alt=\"Chroma_Page_63600_9\" title=\"Chroma_Page_63600_9\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_9.png 600w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_9-300x98.png 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<p>In addition to the basic parameters mentioned above, a new function that allows you to set the number of repetitions for a certain period of time, ranging from 1 to 65535, is also available, which is ideal for testing the instantaneous high-current tolerance of D\/D converters.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17302\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8-1.png\" width=\"749\" height=\"83\" alt=\"Chroma_Page_63600_8-1\" title=\"Chroma_Page_63600_8-1\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8-1.png 749w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8-1-300x33.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_8-1-600x66.png 600w\" sizes=\"auto, (max-width: 749px) 100vw, 749px\" \/><\/p>\n<p>Dynamic pull-load mode provides a unique simulation function that allows the user to set the number of repetitions over a period of time in the range of 1 to 65535. This function is ideal for applications that test the degree of instantaneous high current tolerance of D\/D converters.<\/p>\n<p>The 63600 also offers a unique Dynamic Frequency Sweep mode (shown in Figure 1) that linearly varies its pull-down frequency up to 50kHz, which allows for the measurement of worst-case maximum\/minimum voltage peaks of the object to be measured. The sampling rate of this dynamic frequency sweep function is 500kHz, and Figure 2 shows an example of the maximum\/minimum voltage peaks. Dynamic Load Mode simulates a wide range of different load scenarios and meets the needs of most users. And the 63600's remote load sensor and control circuitry ensure that waveform distortion is minimized under dynamic load operation.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16787\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_11.png\" width=\"771\" height=\"250\" alt=\"Chroma_Page_63600_11\" title=\"Chroma_Page_63600_11\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_11.png 771w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_11-300x97.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_11-768x249.png 768w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_11-600x195.png 600w\" sizes=\"auto, (max-width: 771px) 100vw, 771px\" \/><br \/>\n\u25b2 Figure 1: Scanning waveform<\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16790\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_12.png\" width=\"370\" height=\"259\" alt=\"Chroma_Page_63600_12\" title=\"Chroma_Page_63600_12\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_12.png 370w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_12-300x210.png 300w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><br \/>\n\u25b2 Figure 2: Voltage Peak Measurement<\/p>\n<\/div>\n<\/div>\n<p>According to the Intel ATX 12V Design Guide, when testing the outputs of the power supply, such as +12VDC, +5VDC, and +3VDC, synchronized dynamic pulls are required to test whether the power supply can operate normally under the most severe conditions. The 63600 series provides this dynamic synchronized pull function, which can provide synchronized pull for six groups of power supply outputs in one frame. In addition, in the case of four frames, the number of synchronized dynamic pulling channels can be up to 40 groups. Such flexible module application can increase the utilization rate of each module with the most economical module matching.<\/p>\n<p>In addition to the dynamic pull-load function, for high-power server power supply, it can be synchronized dynamic pull-load of each module in parallel to meet the high-power pull-load application, and the total power of the modules in a frame can be up to 2,000 W dynamic synchronous pull-load.Figure 3 shows the synchronous dynamic waveforms of the modules in parallel, and Figure 4 shows the asynchronous dynamic waveforms of the modules in parallel. In the case of synchronized dynamic pull, the measured voltage peak (Vpeak) is the correct value. In the case of unsynchronized dynamic pull, the measured voltage peak will be the wrong value.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16789\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_13.png\" width=\"440\" height=\"367\" alt=\"Chroma_Page_63600_13\" title=\"Chroma_Page_63600_13\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_13.png 440w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_13-300x250.png 300w\" sizes=\"auto, (max-width: 440px) 100vw, 440px\" \/><br \/>\n\u25b2 Figure 3: Parallel synchronized dynamic loads<\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17300\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_14.png\" width=\"446\" height=\"371\" alt=\"Chroma_Page_63600_14\" title=\"Chroma_Page_63600_14\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_14.png 446w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_14-300x250.png 300w\" sizes=\"auto, (max-width: 446px) 100vw, 446px\" \/><br \/>\n\u25b2 Figure 4: Parallel asynchronous dynamic loads<\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Master\/slave parallel control<\/strong><\/h2>\n<\/div>\n<p>The 63600 has an intelligent master\/slave control mode, when the load power demand increases, it can be connected in parallel (master\/slave control) to achieve the required current and power. When set to master\/slave control mode, all the modules set to master\/slave control form a single load, the user only needs to program the load current on the master module, and the master module will automatically distribute the current to other modules after calculation, which can greatly simplify the user's operation steps. 63600 is equipped with a USB standard interface, GPIB optional interface and Ethernet optional interface, which allows users to use these interfaces for remote control and its power supply. The 63600 is equipped with USB standard interface, GPIB optional interface and Ethernet optional interface, through which users can carry out remote control and other automatic test applications.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16791\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_15.png\" width=\"747\" height=\"310\" alt=\"Chroma_Page_63600_15\" title=\"Chroma_Page_63600_15\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_15.png 747w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_15-300x124.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_15-600x249.png 600w\" sizes=\"auto, (max-width: 747px) 100vw, 747px\" \/><\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16798\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_16.png\" width=\"629\" height=\"438\" alt=\"Chroma_Page_63600_16\" title=\"Chroma_Page_63600_16\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_16.png 629w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_16-300x209.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_16-600x418.png 600w\" sizes=\"auto, (max-width: 629px) 100vw, 629px\" \/><\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Sine wave dynamic measurement<\/strong><\/h2>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p>The 63600 series has a unique sinusoidal pull current, which allows the user to set the pull current bias value (I_DC), the pull sine wave value (I_AC) and the sine wave frequency value (Frequency), and the lowest point of this sinusoidal pull current must not be less than zero amperes. The pull-load waveform is shown in the figure below, CH1: actual pull-load current waveform, CH2: voltage waveform of the measured object. This sine wave pull current function can be applied to D\/D and ATX power supply.<\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17314\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_17.png\" width=\"464\" height=\"365\" alt=\"Chroma_Page_63600_17\" title=\"Chroma_Page_63600_17\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_17.png 464w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_17-300x236.png 300w\" sizes=\"auto, (max-width: 464px) 100vw, 464px\" \/><\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Digital Capture Function<\/strong><\/h2>\n<\/div>\n<p>Users can record the instantaneous waveforms of voltage and current through the digital capture function of the 63600. The digital capture function allows users to operate more conveniently and saves users' time.<\/p>\n<p>The following are specifications for setting parameter values.<\/p>\n<ul>\n<li>Sampling time: 2 microseconds ~ 40 milliseconds \/ Resolution: 2 microseconds (set sampling time frame)<\/li>\n<li>Sampling points: 1~4096 (set total sampling points)<\/li>\n<\/ul>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>User-defined waveform function<\/strong><\/h2>\n<\/div>\n<p>In addition to the general fixed-current, fixed-voltage, fixed-power, fixed-resistance pull-load mode, in the pull-load arbitrary waveforms, the general traditional way is through the computer will be pre-stored waveforms through the DAQ card or simply through the arbitrary waveform generator will be sent to the electronic load for pulling the waveform to achieve the purpose of pulling the load of arbitrary waveforms, as shown in the following figure.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16794\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_18.png\" width=\"1389\" height=\"327\" alt=\"Chroma_Page_63600_18\" title=\"Chroma_Page_63600_18\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_18.png 1389w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_18-300x71.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_18-800x188.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_18-1024x241.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_18-768x181.png 768w\" sizes=\"auto, (max-width: 1389px) 100vw, 1389px\" \/><\/p>\n<p>However, the 63600 series provides another more convenient option - user-defined waveforms, which can simulate the real pull current. The actual current waveform data captured by the oscilloscope or the edited current waveforms can be easily stored in the internal Random Access Memory (RAM) of each module of the 63600 series through the graphical operation software, and then any waveforms defined by the user can be pulled, which saves the cost of DAQ cards or waveform generators, as shown in the figure below. Each module of the 63600 series provides 10 sets of storage space for waveforms and up to 1.2 million waveform points, which is sufficient to provide the required testing.<\/p>\n<p>In addition, while pulling the actual current, the 63600 series also provides the positive and negative values of the maximum peak voltage that occurs during the pulling process, so that the user does not need to observe the voltage changes through an oscilloscope, which greatly saves the time required to confirm the voltage peaks with an oscilloscope.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16797\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_19.png\" width=\"1383\" height=\"271\" alt=\"Chroma_Page_63600_19\" title=\"Chroma_Page_63600_19\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_19.png 1383w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_19-300x59.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_19-800x157.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_19-1024x201.png 1024w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_19-768x150.png 768w\" sizes=\"auto, (max-width: 1383px) 100vw, 1383px\" \/><\/p>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Low Voltage Operating Characteristics<\/strong><\/h2>\n<\/div>\n<p>The 63600's modules have three load operation ranges, each with a minimum operating voltage of 0.6V at full load, and a maximum rated current that can be drawn depending on the current of each range. This low-voltage operation design is suitable for testing D\/D converters, fuel cells and other low-voltage-high-current components. In addition, for operation between 0V and 0.6V*, please refer to the V-I curve on the right for the amount of current that can be pulled.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16792\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_20.png\" width=\"752\" height=\"382\" alt=\"Chroma_Page_63600_20\" title=\"Chroma_Page_63600_20\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_20.png 752w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_20-300x152.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_20-600x305.png 600w\" sizes=\"auto, (max-width: 752px) 100vw, 752px\" \/><br \/>\n\u25b2 Input Characteristics for Model 63640-80-80<\/p>\n<p>Note: Due to the range of on-resistance specifications of the internal power components, when the operating voltage is lower than the minimum operating voltage the actual current value that can be pulled by each load varies.<\/p>\n<\/div>\n<div class=\"col-lg-6 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16793\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_21.png\" width=\"615\" height=\"493\" alt=\"Chroma_Page_63600_21\" title=\"Chroma_Page_63600_21\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_21.png 615w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_21-300x240.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_21-600x481.png 600w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \/><br \/>\n\u25b2Low Voltage &amp; V-I Curve Operating Characteristics (Typical of 63600 Series)<\/p>\n<p>Note: All specifications are measured at load input terminals. (Ambient temperature of 25 \u02daC)<\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>time measurement<\/strong><\/h2>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-7 col-12\">\n<p>The 63600 series is designed with time &amp; measurement features ranging from 2 ms to 100,000 sec. This accurate time measurement feature can be used for battery discharge test and other similar applications. Users need to set the end pull voltage and stop pull time during the battery discharge test.<br \/>\nFor example, when Load ON is pressed to start pulling a load, the 63600's internal timer will automatically start counting until the battery voltage drops to the set termination voltage or when Load OFF is pressed to stop pulling a load, the timer will stop counting. As shown in Figure 5. The time measurement function can be applied to the discharge time of batteries and ultra-capacitors, the trip time of fuses and circuit breakers, the voltage creep time of ATX power supplies and D\/D power supplies, and other applications of the same kind.<\/p>\n<\/div>\n<div class=\"col-lg-5 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-17303\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_22.png\" width=\"631\" height=\"299\" alt=\"Chroma_Page_63600_22\" title=\"Chroma_Page_63600_22\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_22.png 631w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_22-300x142.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_22-600x284.png 600w\" sizes=\"auto, (max-width: 631px) 100vw, 631px\" \/><br \/>\n\u25b2 Figure 5: Battery Discharge Test<\/p>\n<\/div>\n<\/div>\n<div class=\"ccus_title animated wow fadeInDown\" data-wow-delay=\".6s\">\n<h2><strong>Maximum power point tracking function<\/strong><\/h2>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-7 col-12\">\n<p>The 63600 series electronic load has a built-in maximum power point tracking function, which is mainly used for testing the maximum power point tracking of solar panels. Simply connect the solar panel directly to the 63600 Series electronic load and the built-in algorithm will track the maximum power point, in addition, the total energy consumed can also be calculated.<\/p>\n<\/div>\n<div class=\"col-lg-5 col-12\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16795\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_23.png\" width=\"991\" height=\"441\" alt=\"Chroma_Page_63600_23\" title=\"Chroma_Page_63600_23\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_23.png 991w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_23-300x134.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_23-800x356.png 800w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_63600_23-768x342.png 768w\" sizes=\"auto, (max-width: 991px) 100vw, 991px\" \/><\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li>Power range: 100W x2 (dual channel), 300W, 400W<\/li>\n<li>Voltage range: up to 600V<\/li>\n<li>Can carry 5 modules up to 2000W, load module up to 400W<\/li>\n<li>Up to 10 channels in a single frame<\/li>\n<li>Low Voltage Operating Characteristics 0.6V@80A(Typical)<\/li>\n<li>Constant current, constant resistance, constant voltage and constant power operation modes<\/li>\n<li>Constant impedance (CZ) mode emulation capacitive load turn-on<\/li>\n<li>Parallel mode provides high current and high power applications up to 2kW<\/li>\n<li>User-defined waveforms<\/li>\n<li>Multi-channel synchronized timing control<\/li>\n<li>Up to 50kHz automatic frequency conversion dynamic sweep (Sweep)<\/li>\n<li>Real-time power supply load transient response simulation and voltage peak (Vpk+\/-) measurement<\/li>\n<li>100 sets of timing and load values can be programmed directly from the front panel.<\/li>\n<li>Highly accurate voltage and current measurement<\/li>\n<li>High-speed and accurate digitizing measurement\/data acquisition<\/li>\n<li>Overcurrent\/overload protection of the object to be measured, voltage, current and protection point measurement of the maximum power point (Pmax).<\/li>\n<li>time measurement<\/li>\n<li>Short circuit simulation<\/li>\n<li>Boot Self-Diagnostics<\/li>\n<li>Protection functions: over-current, over-power, over-temperature protection and over-voltage, positive and negative reverse alarms<\/li>\n<li>Ethernet, USB, GPIB interface<\/li>\n<\/ul>","protected":false},"featured_media":10792,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[3527],"product_cat":[404],"product_tag":[2871,1899,1892],"class_list":{"0":"post-9619","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-chroma","7":"product_cat-dc-load","8":"product_tag-2871","9":"product_tag-1899","10":"product_tag-1892","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/9619","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=9619"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/10792"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=9619"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=9619"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=9619"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=9619"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}