{"id":9650,"date":"2025-02-06T10:33:42","date_gmt":"2025-02-06T02:33:42","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/9650.html"},"modified":"2025-02-13T19:27:21","modified_gmt":"2025-02-13T11:27:21","slug":"%e8%84%89%e5%86%b2%e6%b5%8b%e8%af%95%e4%bb%aamodel-19311-series","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/9650.html","title":{"rendered":"Pulse Tester Model 19311 Series"},"content":{"rendered":"<p>Chroma 19311 series pulse testers can apply high voltage pulses to lead-acid battery cells that have not yet been filled with electrolyte to test the insulation quality between the positive and negative plates, as well as applying high voltage pulses to metal-film resistors to test the insulation quality of laser cuts and so on. With pulse output voltages up to 6kV, four-wire voltage measurement, and a high-speed sampling rate of 200MHz, the 19311 series can pulse test battery cells or metal film resistors, allowing users to choose between a single-channel tester (Model 19311) or a multi-channel scanning tester (Model 19311-10).<\/p>\n<p>The 19311-10 model has 10 channels, and can utilize the scanning test method to do multi-channel switching output to test multiple battery cells, and can test up to 9 battery cells at a time. With the A190362 scanning fixture, it can support up to 25 channels and test 24 battery cells at a time. The advantage of rapid scanning test for multiple battery cells greatly saves testing time and labor costs, and is suitable for use in production lines to increase production capacity.<\/p>\n<p>Before lead-acid batteries are filled with electrolyte, the main purpose of using high-voltage pulses to test the positive and negative plates of a lead-acid battery cell is to check the insulation distance and quality between the positive and negative plates, the existence of the isolation film, and whether there is a short-circuit between the positive and negative plates, in order to find out inferior or defective battery cells. The 19311 series analyzes the difference in insulation quality of the battery cells through the internal inductance and the high voltage shock attenuation of the battery cells.<\/p>\n<p>The main purpose of using high voltage pulses to test metal film resistors is to detect the insulation distance and quality of the laser-cut grooves of metal film resistors, and to detect any potential short-circuit defects, so that inferior or defective products can be revealed. The 19311 series utilizes high voltage pulses to apply a brief, low energy high voltage to metal film resistors connected in parallel to detect defects in their internal insulation quality.<\/p>\n<p>Therefore, pulse testing with the 19311 series improves the insulation quality of lead-acid battery cells, metal film resistors, etc., and ensures long-lasting reliability of the products.<\/p>\n<div class=\"sidebar\">\n<div id=\"sidenav\" class=\"collapse in\">\n<ul id=\"pills-tab\" class=\"nav navbar\" role=\"tablist\">\n<li class=\"nav-item\">pulse test<\/li>\n<li class=\"nav-item\">Three abnormal causes of lead-acid battery cells<\/li>\n<li class=\"nav-item\">Four abnormal causes of metal film resistors<\/li>\n<li class=\"nav-item\">Eight judgment functions<\/li>\n<li class=\"nav-item\">test application<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<div id=\"pills-tabContent\" class=\"tab-content\">\n<div id=\"Group_1\" class=\"tab-pane fade show active\" role=\"tabpanel\" aria-labelledby=\"Group_1\">\n<div class=\"row\">\n<div class=\"col-6\"><img decoding=\"async\" class=\"img-fluid\" src=\"https:\/\/www.chroma.com.cn\/Upload\/images\/Products\/Safety\/19311\/2023\/Chroma_Page_19311_1-SC.png\" alt=\"Chroma 19311 Pulse Tester\" \/><br \/>\n\u25b2 Pulse Test Waveform Schematic<\/div>\n<div class=\"col-6\">\n<p>Pulse testing involves applying a sufficiently high test voltage (up to 6 kV) with a very short duration (&lt;160 uS) to the object to be tested (lead-acid battery cell, metal film resistor).<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"row\">\n<div class=\"col-6\">\n<p>When the switch is open to the lead-acid battery cell to apply pulse test, due to the 19311 series of internal resonant inductor, so the battery cell will be resonant with the 19311 series of internal resonant inductance and charging capacitor, this resonant waveform of the highest voltage peaks can be detected abnormal voltage withstand battery cell. When the switch is turned off, the lead-acid battery cell will only resonate with the resonant inductor inside the 19311 series, and the peak voltage of this resonant waveform will be attenuated, which represents the good or bad insulation quality of the battery cell. The resonance waveform is analyzed or compared with the resonance waveform of the sample to determine whether the lead-acid battery cells are good. Pulse testing of lead-acid battery cells that have not yet been filled with electrolyte is done mainly to find out whether the lead-acid battery cells have poor insulation or the isolation film does not exist before the electrolyte is filled.<\/p>\n<\/div>\n<div class=\"col-6\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16570\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_2-SC.png\" width=\"631\" height=\"530\" alt=\"Chroma_Page_19311_2-SC\" title=\"Chroma_Page_19311_2-SC\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_2-SC.png 631w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_2-SC-300x252.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_2-SC-600x504.png 600w\" sizes=\"auto, (max-width: 631px) 100vw, 631px\" \/><br \/>\n\u25b2 Testing the equivalent circuit of a lead-acid battery cell<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"row\">\n<div class=\"col-6\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16571\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_3-SC.png\" width=\"630\" height=\"523\" alt=\"Chroma_Page_19311_3-SC\" title=\"Chroma_Page_19311_3-SC\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_3-SC.png 630w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_3-SC-300x249.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/Chroma_Page_19311_3-SC-600x498.png 600w\" sizes=\"auto, (max-width: 630px) 100vw, 630px\" \/><br \/>\n\u25b2 Equivalent Circuit for Testing Metal Film Resistors<\/div>\n<div class=\"col-6\">\n<p>Using AC\/DC voltage to detect metal foreign matter at the cutout of a metal film resistor can make it difficult to detect abnormal insulation quality at the cutout of a metal film resistor because the test voltage at the cutout is too low\/not high enough and the test voltage cannot be increased because the test power is too high, making it difficult to detect insulation quality abnormality at the cutout of a metal film resistor by using AC\/DC voltage, so it is necessary to use the Pulse Test to detect insulation quality at the cutout of a metal film resistor. When a pulse test is applied to a metal film resistor with the switch open, the resonant inductor inside the 19311 Series generates a self-resonance, and the resonance waveform of the test can be analyzed or compared with the resonance waveform of a sample, and metal film resistors with abnormal voltage withstand can be detected. After the switch cutoff is turned off, the difference in the peak decay state of the resonant waveform voltage indicates the difference in resistance value of the resistor because the metal film resistor is connected in parallel with the resonant inductor. Pulse testing of metal film resistors is mainly done to detect whether there is any insulation problem at the laser cutout inside the encapsulated metal film resistor, so that poorer quality products will show their true colors. Detecting whether there are potential problems of poor insulation quality and insufficient insulation distance at the laser cut of metal film can ensure that metal film resistors will not deteriorate under normal operating conditions due to poor insulation quality or insufficient insulation distance at the laser cut, resulting in changes in resistance value, reducing the chance of causing safety accidents, and safeguarding the reliability of electrical products for long term use.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"sub-title\">Product Features<\/div>\n<ul>\n<li>Up to 6kV pulse test output (depending on the capacitance of the object to be tested)<\/li>\n<li>Programmable pulse interval 30ms~3000ms<\/li>\n<li>8 adjudication:\n<ul>\n<li>Area Comparison<\/li>\n<li>Comparison of area difference<\/li>\n<li>Flutter Detection<\/li>\n<li>quadratic differential detection<\/li>\n<li>First voltage peak<\/li>\n<li>Third voltage peak<\/li>\n<li>wave-to-peak ratio<\/li>\n<li>crest difference ratio<\/li>\n<\/ul>\n<\/li>\n<li>Contact check (capacitive products)<\/li>\n<li>Crash voltage analysis mode (BDV Mode)<\/li>\n<li>High sampling rate (200MHz)<\/li>\n<li>Supports up to 25-channel scanning test (19311-10 with A190362 optional)<\/li>\n<li>English\/Traditional\/Simplified Chinese Interface<\/li>\n<li>Support for USB flash drives\n<ul>\n<li>Waveforms, test conditions\/results storage<\/li>\n<li>frame grabbing<\/li>\n<li>Memory data backup<\/li>\n<\/ul>\n<\/li>\n<li>Graphic color display<\/li>\n<li>Standard LAN, USB, RS232 control interface<\/li>\n<\/ul>\n<div class=\"sub-title\"><strong>Application Areas<\/strong><\/div>\n<ul>\n<li>lead-acid battery<\/li>\n<li>Metal Film Resistors (MELF, SMD\/Chip)<\/li>\n<\/ul>","protected":false},"featured_media":10692,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[3527],"product_cat":[2892],"product_tag":[1997],"class_list":{"0":"post-9650","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-chroma","7":"product_cat-lead-acid-battery-cell-testing","8":"product_tag-1997","10":"first","11":"outofstock","12":"shipping-taxable","13":"product-type-variable"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/9650","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=9650"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/10692"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=9650"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=9650"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=9650"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=9650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}