{"id":9702,"date":"2025-02-06T11:25:00","date_gmt":"2025-02-06T03:25:00","guid":{"rendered":"https:\/\/www.wbyq.cn\/product\/9702.html"},"modified":"2025-02-13T19:26:05","modified_gmt":"2025-02-13T11:26:05","slug":"pav%e7%b3%bb%e5%88%97%e6%99%ba%e8%83%bd%e5%8f%af%e5%8f%98%e5%bc%80%e5%85%b3%e5%9e%8b%e7%94%b5%e6%ba%90","status":"publish","type":"product","link":"https:\/\/ad.wbyq.cn\/en\/product\/9702.html","title":{"rendered":"PAV Series Intelligent Variable Switching Power Supply"},"content":{"rendered":"<h2 class=\"mod_h22\">one's special ability or strong points<\/h2>\n<div class=\"mod_content_txt\">\n<h3 class=\"mod_h33\">Communication interfaces are standard<br \/>\nA new classic in high-performance switching test power supplies<\/h3>\n<div class=\"mod_img_center\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16362\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_2-12.png\" width=\"700\" height=\"436\" alt=\"img_2-12\" title=\"img_2-12\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_2-12.png 700w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_2-12-300x187.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_2-12-600x374.png 600w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/div>\n<h3 class=\"mod_h33\">Wide variety of external controls and applications - Analog controllers and monitoring terminals are available for a variety of applications.<\/h3>\n<h3 class=\"mod_h34\">remotely sensed<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>Compensates for voltage drop caused by wiring from the output terminals to the load terminals of the PAV series.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16363\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_3-11.png\" width=\"356\" height=\"136\" alt=\"img_3-11\" title=\"img_3-11\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_3-11.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_3-11-300x115.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">Remote monitoring of output voltage and current and CV\/CC signaling<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>In proportion to the output voltage\/current of the PAV series, 0 to 5 V or 0 to 10 V will be output, and the operation status will be HIGH in CV constant voltage mode and LOW in CC constant current mode.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16364\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_4-10.png\" width=\"356\" height=\"144\" alt=\"img_4-10\" title=\"img_4-10\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_4-10.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_4-10-300x121.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">Parallel operation (single control operation)<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>Max can connect up to 6 PAV series in parallel to increase the output current.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16365\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_5-9.png\" width=\"356\" height=\"150\" alt=\"img_5-9\" title=\"img_5-9\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_5-9.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_5-9-300x126.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">Output voltage and current control by external voltage<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>The output voltage as well as the output current can be controlled by connecting the voltage to the PAV series from outside.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16366\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_6-8.png\" width=\"356\" height=\"128\" alt=\"img_6-8\" title=\"img_6-8\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_6-8.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_6-8-300x108.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">Output ON\/OFF control<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>ON\/OFF of the PAV series can be externally controlled.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16367\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_7-6.png\" width=\"356\" height=\"138\" alt=\"img_7-6\" title=\"img_7-6\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_7-6.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_7-6-300x116.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">daisy chain connection<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>Multiple PAV series products are used to construct a multiple power supply system, and when one of the power supplies fails, all of its constituent power supply outputs can be stopped.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16368\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_8-6.png\" width=\"356\" height=\"120\" alt=\"img_8-6\" title=\"img_8-6\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_8-6.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_8-6-300x101.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">tandem operation<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>Max can connect two PAV series products in series to increase the output voltage. A dual output structure is also available.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16369\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_9-4.png\" width=\"356\" height=\"190\" alt=\"img_9-4\" title=\"img_9-4\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_9-4.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_9-4-300x160.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">PS_OK signal<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>Abnormalities are notified via TTL outputs when the protection function operates. The PS_OK level is HIGH in the normal operation state.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16370\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_10-3.png\" width=\"356\" height=\"126\" alt=\"img_10-3\" title=\"img_10-3\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_10-3.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_10-3-300x106.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h34\">Output voltage and current controlled by external resistors<\/h3>\n<div class=\"mod_conbox3\">\n<div class=\"text\">\n<p>The output voltage as well as the output current can be controlled by external control of the PAV series.<\/p>\n<\/div>\n<div class=\"img\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16371\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_11-3.png\" width=\"356\" height=\"152\" alt=\"img_11-3\" title=\"img_11-3\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_11-3.png 356w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_11-3-300x128.png 300w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/div>\n<\/div>\n<h3 class=\"mod_h33\">USB\/RS232C\/RS485 control<\/h3>\n<p>The USB\/RS232C\/RS485 interfaces are standard on the PAV series, and Max can connect up to 31 PAV series for control. In addition, the USB\/RS232C\/RS485 interfaces are built into the main unit of the PAV series.<\/p>\n<div class=\"mod_img_center\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16372\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_12-2.png\" width=\"700\" height=\"262\" alt=\"img_12-2\" title=\"img_12-2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_12-2.png 700w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_12-2-300x112.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_12-2-600x225.png 600w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/div>\n<h3 class=\"mod_h33\">Parallel operation \/ synchronized operation<\/h3>\n<p>Parallel operation (PAV series with the same rating) and synchronized operation (synchronized triggering) are possible. Furthermore, integration is realized by using the optional cabinet adapter KRA2-PAV (Max. installation of 6 units) and the half-size integrated housing CC01-PAV (Max. installation of 3 units), which makes cabinet assembly and removability easier.<\/p>\n<p class=\"small\">Parallel and synchronized operation is possible even without the optional KRA2-PAV and CC01-PAV.<\/p>\n<div class=\"mod_img_center\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16373\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_13-2.png\" width=\"700\" height=\"280\" alt=\"img_13-2\" title=\"img_13-2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_13-2.png 700w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_13-2-300x120.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_13-2-600x240.png 600w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/div>\n<h3 class=\"mod_h34\">Example of use of optional parts<\/h3>\n<div class=\"mod_img_center2 clearfix\">\n<div>\n<p class=\"mt0\">Max up to 4.8kW (Max 6 units)<br \/>\nOn a 19-inch general purpose cabinet<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16374\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_14-2.png\" width=\"349\" height=\"140\" alt=\"img_14-2\" title=\"img_14-2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_14-2.png 349w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_14-2-300x120.png 300w\" sizes=\"auto, (max-width: 349px) 100vw, 349px\" \/><\/div>\n<div>\n<p class=\"mt0\">Integration of 3 power supplies<br \/>\nUse as a desktop power supply<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16375\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_15-2.png\" width=\"349\" height=\"140\" alt=\"img_15-2\" title=\"img_15-2\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_15-2.png 349w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_15-2-300x120.png 300w\" sizes=\"auto, (max-width: 349px) 100vw, 349px\" \/><\/div>\n<\/div>\n<\/div>\n<h2 class=\"mod_h22\">Product Lineup<\/h2>\n<div class=\"mod_content_txt\">\n<div class=\"mod_img_center mt30\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-16376\" src=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_16.png\" width=\"700\" height=\"476\" alt=\"img_16\" title=\"img_16\" srcset=\"https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_16.png 700w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_16-300x204.png 300w, https:\/\/szwanbo.oss-cn-shenzhen.aliyuncs.com\/wp-content\/uploads\/2025\/02\/img_16-600x408.png 600w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>PAV series is a high power density, high performance, ultra-compact constant voltage (CV)\/constant current (CC) DC stabilized power supply. 4 types of Max output power of 200W, 400W, 600W, 800W, and output voltage of 10V to 650V, with 64 models.<sup>\u203b1<\/sup>. With desktop use in mind, all models have a height of 2U (88mm), which is a high power density specification with unified dimensions. This series allows not only analog control but also timing setting by equipping a CPU. The PAV series is also equipped with a parallel operation function for expanding output current (Max. 6 units).<sup>\u203b2<\/sup>and synchronized operation functions<sup>\u203b3<\/sup>. USB, RS232C, RS485 for system upgrades are standard.<sup>\u203b4<\/sup>Communication interface. LAN interface is also available as an option<sup>\u203b5<\/sup>. Built-in harmonic current suppression circuit with a power factor of 0.99, taking into account the power environment.<\/p>\n<p class=\"small\">\u203b1: Including models with LAN.<br \/>\n\u203b2: PAV series with the same rated value<br \/>\n\u203b3: Trigger synchronization<br \/>\n\u203b4: RS232C, RS485 conversion cable is required separately.<br \/>\n\u203b5: Factory option<\/p>","protected":false},"featured_media":10515,"comment_status":"open","ping_status":"closed","template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[3539],"product_cat":[52,67],"product_tag":[2951,2943],"class_list":{"0":"post-9702","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-kikusui","7":"product_cat-tydzcs","8":"product_cat-dc-electronic-loads","9":"product_tag-2951","10":"product_tag-2943","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product\/9702","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/comments?post=9702"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media\/10515"}],"wp:attachment":[{"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/media?parent=9702"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_brand?post=9702"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_cat?post=9702"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ad.wbyq.cn\/en\/wp-json\/wp\/v2\/product_tag?post=9702"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}