Product Overview: Fluke 1770 Series Three-Phase Power Quality Analyzers
Automatic measurement. More flexibility. Better power quality troubleshooting.
The Fluke 1770 Series three-phase power quality analyzers make power quality documentation, troubleshooting, and analysis easy.Designed for faster, easier power quality studies, the 1770 Series offers automated measurements, an intuitive user interface and setup, excellent specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuitry, eliminating the need to find power outlets or use long extension cords.
With the 1770 Series, you won't miss critical power quality events-from fast transients up to 8 kV and harmonics up to 30 kHz to dips and spikes-as well as voltage, current, and power measurements, enabling you to analyze the full range of your electrical system.
Automatic capture of measurement data
Whether you're performing a quick system check or a detailed power quality study, consistent data is critical, and the Fluke 1770 Series offers a unique automatic measurement data capture system that helps you ensure the right data is captured every time, with the flexibility to select and adjust specific parameters as needed. By default, more than 500 power quality parameters are captured, and guided setup makes it easy to select the right parameters for the system you're working on. Recorded data can be instantly viewed, downloaded and shared through Fluke Energy Analyze Plus software, so you don't have to wait for recording to complete to view results or analyze data.


Excellent measurement confidence
The Fluke 1770 Series is a 2-in-1 device that combines the troubleshooting capabilities of a power quality meter with the powerful analysis and logging capabilities of a stand-alone power quality analyzer into one easy-to-use handheld device.
"The Power Quality Meter feature gives you instant access to real-time on-screen data in the field so you can quickly identify potential problems during troubleshooting. Power quality research is made easy with detailed Power Quality Logging and Analysis features that guide you through the setup process, ensuring you capture the right data every time. Combine these measurement modes with the unique Measurement Connection Autocorrect feature, and you can feel confident that you won't have to worry about going back for a second measurement, even if you're not sure what you're looking for at the start.
Powerful analysis software for easy report creation
Fluke 1770 Series power quality analyzers come standard with powerful Fluke Energy Analyze Plus software, which eliminates the hassle of using other multi-purpose applications.Energy Analyze Plus helps you evaluate power quality data right out of the box, without extensive training.
Energy Analyze Plus makes it easier than ever to download, analyze, track and report power quality and energy data. Quickly compare results to historical data values, benchmark against industry standards, compare measured data to local standards, and get a more complete picture of what's happening throughout your facility, even while data is still being collected.Energy Analyze Plus provides unified support for the Fluke 1730, 1740, and 1770 series of power loggers and power quality analyzers.
- "Office" and "field" setup and downloads via PC applications
- Easily download data using a USB flash drive, WiFi, LTE, wired Ethernet or USB cable
- Analyze every measurement detail of energy consumption and power quality conditions with automated report generation tools
- One-click report generation tool to create standardized reports compliant with EN 50160, IEEE 519, GOST 33073 IEC 61000-2-2, etc., or export data in PQDIF or NeQual compliant formats or CSV format for use in third-party software
- Advanced Analytics allows users to select any of the available recording parameters and create highly customized measurement views for advanced data correlation


High-speed voltage transient capture
Transients negatively impact otherwise well-run systems on a daily basis, and the damage they can cause to equipment cannot be underestimated. Whether your system is experiencing impulse transients or oscillatory transients, the results can be devastating, causing problems ranging from insulation failure to total equipment failure.The Fluke 1775 and Fluke 1777 feature advanced transient capture technology to help you clearly identify high-speed voltage transients, so you can get the data you need to stop them from occurring. The Fluke 1775 Power Quality Analyzer features 1MHz sampling to capture fast transients, while the Fluke 1777 Power Quality Analyzer features 20MHz sampling to capture fleeting transients and provide detailed information.
From conventional industrial systems to renewable energy systems to electric vehicles, we offer you a comprehensive range of services.
Designed to be safe and easy to use in all measurement environments, the Fluke 1770 Series allows you to capture a wide range of power quality variables as well as high-speed waveforms, high-speed transients, and higher-frequency harmonics, all of which can be viewed instantly on a large, high-resolution screen. With excellent CAT IV 600 V/CAT III 1000 V overvoltage ratings, these analyzers can be used on the incoming line or downstream, measuring AC and DC inputs and harmonics up to 30 kHz. With the 1770 Series, you can confidently capture the data you need to make better maintenance decisions, no matter the task.
| appliance | 1773 | 1775 | 1777 |
|---|---|---|---|
| Power analysis and load testing | - | - | - |
| harmonic analysis (physics) | - | - | - |
| Annoying circuit breaker trips | - | - | |
| Power quality analysis of the public power grid | - | - | |
| Detection of equipment failures caused by transients | - | - |

Compliance with international standards
The Fluke 1770 Series delivers the superior accuracy you've come to expect from Fluke power quality analyzers, using future standards that comply with IEC 61000-4-30 Class A, Version 3. In addition, the 1770 Series has been designed to meet the future requirements of Class A version 3, complying with EN 50160 and IEEE 519 standards, so you can be ready to meet the measurement requirements of the future today.

Work wherever, whenever and however you want
No two days in the field are the same. You need a power quality analyzer that's ready to do the work you need when you arrive, and the Fluke 1770 Series has a full suite of accessories and built-in features to make it easy to get the job done. The slim, ergonomic design and integrated carrying strap make it easy to hold, and the included suspension kit makes it easy to secure the analyzer inside the cabinet. The integrated internal power supply allows the unit to be powered directly through the circuit under test, while the 90-minute battery life helps ensure that data can be accessed and viewed even when not connected to a powered system.
Depending on your requirements, data can be quickly and easily transferred to a PC using USB C, USB A, Ethernet, Wi-Fi, and cellular network support options.With the built-in GPS module and optional double-insulated antenna extension cable (for amplifying GPS signals indoors), you can easily time-synchronize your data for more accurate troubleshooting and analysis.
Calculate current harmonic limits
When downloading data from a Fluke 1770 Series power quality analyzer, the included Energy Analyze Plus software package compares voltage measurements and current harmonics statistics to different standards, such as EN 50160 or IEEE 519, to determine if they are out of compliance limits. This powerful predictive maintenance feature allows you to observe current harmonics before voltage distortion occurs, preventing unexpected failures or non-compliance and extending system uptime. As inverter-based loads and power generation proliferate, controlling current harmonics becomes increasingly important to help ensure reliable power quality and avoid system downtime.

Product Specification: Fluke 1770 Series Three-Phase Power Quality Analyzer
Main features
| Voltage Input | |
|---|---|
| Number of inputs | 4 inputs, 3-phase and zero with respect to PE (5 connectors) |
| Measurement category | 1000 V CAT III/600 V CAT IV |
| Maximum Input Voltage | 1000 V rms/1000 V dc (1700 Vpk) |
| Rated voltage range | Star and single phase: variable (50 V - 1000 V) Triangle: variable (100 V - 1000 V) Nominal voltage according to IEC 61000-4-30 Class A (V)din) 100 V - 690 V |
| Input Impedance | 10 MΩ (between P-P and P-N), 5 MΩ (between P-PE and N-PE) |
| bandwidths | DC up to 30 kHz for power quality measurements, excluding transients |
| resolution (of a photo) | 24-bit synchronized sampling |
| sampling frequency | 80 kS/s at 50/60 Hz |
| resizing | 1:1, variable, for voltage transformers |
| voltage transient | |
|---|---|
| Measurement range | ±8 kV |
| sampling rate | 1775: 1 MS/s 1777: 1 MS/s, 20 MS/s |
| bandwidths | DC to 1 MHz |
| flip-flop (electronics) | Adjustable trigger level. Trigger on high frequency component > 1.5 kHz |
| resolution (of a photo) | 14-bit synchronized sampling |
| Current Input | ||
|---|---|---|
| Number of inputs | 4 inputs (3-phase and zero line), automatic range selection for connected sensors | |
| range (of scales or measuring equipment) | exchanges | 1 A to 1500 A with i17XX-FLEX1500 12 1 A to 1500 A with i17XX-FLEX1500 18 1 A to 1500 A with i17XX-FLEX1500 24 3 A to 3000 A with i17XX-FLEX3000 24 6 A to 6000 A with i17XX-FLEX6000 36 40 mA to 40 A with clamp i40s-EL 4 A to 400 A with clamp i400s-EL |
| direct current (D.C.) | 20 A to 2000 A with clamp 80i-2010-EL | |
| bandwidths | DC to 30 kHz | |
| resolution (of a photo) | 24-bit synchronized sampling | |
| sampling frequency | 80 kS/s at 50/60 Hz | |
| resizing | 1:1, variable | |
| Input Voltage | Clamp: 50 mV / 500 mV rms; CF 2.8 Rogowski coil: 15 mV/150 mV rms @ 50 Hz, 18 mV/180 mV rms @ 60 Hz; CF 4 All nominal probe ranges |
|
| Input Impedance | 11 kΩ | |
| Aux Input | |
|---|---|
| Wired connection, using 17XX-AUX adapter | |
| Number of inputs | 2 |
| Input Range | DC: 0 V dc to ± 10 V dc 0 V to 1000 V dc |
| Input Impedance | DC: 2.92 MΩ |
| proportionality factor | Format: mx + b (gain and offset) user configurable |
| Displayed units | User configurable (up to 8 characters, e.g. °C, psi or m/s) |
| Voltage and current data acquisition | |
|---|---|
| Input power frequency | DC, 50/60 Hz 15 % (42.5 Hz ... 57.5 Hz, 51 Hz ... 69 Hz) |
| topology of a network (elec.) | 1-φ, 1-φ IT, split-phase, 3-φ triangle, 3-φ star IT, 3-φ Aron/Blondel (binary triangle), 3-φ triangle open branch, 3-φ high-branching triangle |
| data storage | Fluke 1773/1775: 8 GB memory (can be expanded with a microSD card) Fluke 1777: 32 GB microSD card (installed) |
| Memory capacity | Typical: 10 logging sessions of 8 weeks with 1-minute intervals and 100 events. The number of available logging sessions and the logging period depends on the user's needs |
| Real-time accuracy | Internal: 3 ppm (0.26 s per day, 8 s per month) NTP (Internet Time): based on Internet latency, typically < 0.1 s, relative to Coordinated Universal Time (UTC) GPS: < 1 ms relative to Coordinated Universal Time (UTC) |
| trend interval | |
|---|---|
| Parameters measured | Please refer to the operating manual |
| trend interval | User selectable: 1 s, 3 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, 30 min |
| Average interval, min/max | Voltage, Current: ½ cycle RMS (20 ms @ 50 Hz, 16.7 ms @ 60 Hz) Aux, power: 200 ms |
| THD | Total harmonic distortion (THD) for voltage and current based on 50 harmonics |
| Power quality measurements | ||
|---|---|---|
| Parameters measured | Please refer to the operating manual | |
| harmonic (wave with frequency an integer multiple of the fundamental) | h0 ... h50 % fundamental and RMS for voltage, current and power Phase angle of voltage and current up to h11 |
|
| interharmonic | ih0... ih50 % fundamental and RMS for voltage and current |
|
| superharmonic | 2-9 kHz, 200 Hz Frequency Points 9-30 khz, 2 kHz frequency points RMS for voltage and current |
|
| Harmonic Measurement Methods | Group harmonics, subgroup harmonics and single harmonics bin according to IEC 61000-4-7. Methods automatically selected based on configured power quality standards or user configurable. |
|
| THD | Calculations based on up to 50th harmonic (depending on the selected power quality standard) | |
| power signal (of an electrical device etc) | 2 frequencies ranging from 110 Hz to 3000 Hz | |
| event | input voltage | Dips, rises, transient breaks, rapid voltage changes, power signals, waveform deviations, transients |
| amps | surge current | |
| trigger record | Voltage and current half-cycle RMS duration 10 s Voltage and current waveforms for 10/12 cycles Power signal: 200 ms RMS of power signal voltage, max. 120 s Transients: Voltage waveforms (Fluke 1777: 1 MS/s or 20 MS/s, 500000 pts; Fluke 1775: 1 Ms/s, 25000 pts) |
|
| standards-compliant | |
|---|---|
| power supply | IEEE 1459 |
| harmonic (wave with frequency an integer multiple of the fundamental) | IEC 61000-4-7: Class 1 IEEE 519 (short-time and ultra-short-time harmonics) |
| flicker | IEC 61000-4-15 Class F1 |
| power quality | IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI |
| Power quality compliance | en 50160 + gest + nequal + netcode + fol |
| connector | |
|---|---|
| Ethernet | 1 Gbit/s 1000BASE-T |
| USB Type A | USB 2.0 Hi-Speed USB flash drive for transferring measurement data, firmware updates and license installations. Maximum supply current: 500 mA |
| USB-C | USB 2.0 Hi-Speed for data download to PC and calibration (requires USB Type A to USB-C or USB-C to USB-C cable) Analyzer auxiliary power supply (requires USB C power adapter, supports PD 2.0 or later protocol, supports 9 V 1.8 A) USB 3.0 SuperSpeed for USB-C flash drives for transferring measurement data, firmware updates and license installations. Maximum supply current: 900 mA |
| WiFi/BLE Module1 | 802.11 ac 2.4 GHz/5 GHz with concurrent access point and client mode support Bluetooth 5.0/BLE Antennas: internal and external2 |
| LTE/4G Modules3 | LTE-A Cat 12 Global LTE-A and UMTS/HSPA+ coverage Antenna: External2 |
| GPS | MCX connector for GPS/GLONASS connection2 GNSS antennas |
| 1 Not available on 177X/BASIC models. 2 Requires 5m extension cable, Fluke part number: 5263915 3 Availability and support providers vary by country/region. Please consult your local Fluke representative. |
|
Electrical measurement accuracy
| parameters | range (of scales or measuring equipment) | resolution (of a photo) | Inherent accuracy at reference conditions % of Reading + % of Full Scale |
|
|---|---|---|---|---|
| input voltage | 1000 V | 0.1 V | 0.1 of nominal voltage % in line with IEC 61000-4-30 Class A standard1,2 ±(0.04 % + 0.004 %)3 |
|
| Voltage dips and surges | - | 0.1 V | 0.2 of nominal voltage %1,2 | |
| voltage transient | ±8 kVpk | - | ±5 % +0.25 %) | |
| Voltage harmonics/interharmonics | 100 % | 0.1 %/0.1 mV | ≥1 % Nominal voltage1: ±2.5 of reading % <1 % Nominal voltage 1: ±0.025 Nominal voltage |
|
| Total harmonic distortion of voltage | 100 % | 0.1 %/0.1 V | ±(2.5 % + 0.5 %) | |
| Voltage distortion 2-9 kHz | 100 V max. | 0.1 mV | ±(2.5 % + 0.1 V) | |
| Voltage distortion 9-30 kHz | 100 V max. | 0.1 mV | ±(2.5 % + 0.1 V) | |
| amps (Rogowski clamp mode) |
With the iFlex 1500 A. i17XX-FLEX1500 18 |
150 A 1500 A |
0.01 % 0.1 A |
±(1 % + 0.02 %) |
| With the iFlex 3000 A. i17XX-FLEX3000 24 |
300 A 3000 A |
0.01 A 0.1 A |
±(1 % + 0.03 %) | |
| With the iFlex 6000 A. i17XX-FLEX6000 36 |
600 A 6000 A |
0.1 A 1 A |
±(1.5 % + 0.03 %) | |
| Using AC clamps 40 A. i40s-EL |
4 A 40 A |
0.001 A 0.01 A |
±(0.7 % + 0.02 %) | |
| Using AC clamps 400 A. i400s-EL |
40 A 400 A |
0.01 A 0.1 A |
±(2 % + 0.2 %) ±(0.7 % + 0.1 %) |
|
| Use of AC/DC clamps 2000 A, 80i-2010s-EL |
200 A 2000 A |
0.01 A 0.1 A |
±(0.8 % + 0.2 %) | |
| Current min/max | 100 % | Defined by Annex | Inherent Accuracy x2 | |
| Current harmonics/interharmonics | 100 % | 0.1 %/0.01 A | ≥3 % Nominal current: ±2.5 of reading % 4 <3 % Nominal current: Nominal current ±0.15 % |
|
| Total harmonic distortion of current | 100 % | 0.1 % | ±(2.5 % + 0.5 %) | |
| frequency | 42.5 Hz ... 69 Hz | 0.001 Hz | ±0.01 Hz | |
| voltage imbalance | 100 % | 0.1 % | ±0.15 % | |
| current imbalance | 100 % | 0.1 % | ±0.15 % | |
| Flicker Pinst, Pst, Plt | 0 to 20 | 0.01 | 5 % | |
| Power Supply Signal Voltage | Up to 3 kHz 0-15 % of nominal voltage |
0.1 V/0.1 % | 1-3 % Nominal voltage: ±0.15 of nominal voltage % 3-15 % Nominal voltage: ±5 of reading % |
|
| AUX Input | ±10 V | 0.1 mV | ±(0.2 % + 0.05 %) | |
| 1 Nominal voltage in the range of 100 V to 690 V; also known as Udin. 2 0 °C to 45 °C: inherent accuracy x2. 0 °C to 45 °C: inherent accuracy x3. 3 For calibration laboratories only 4 Using the iFlex 1500A, I17XX-FLEX1500 18 |
||||
Power/Electricity
| parameters | DC Input1 | Clamp i40S-EL |
|---|---|---|
| Power range W, VA, var | Clamp: 50 mV/500 mV Rogowski: 15 mV/150 mV |
4 A/40 A |
| Clamp: 50 W/500 W Rogowski: 15 W/150 W |
4k W/40 kW | |
| Maximum resolution W, VA, var | 0.1 W | 1 W/10 W |
| Phase (voltage to current)1 | ±0.2° | ±1° |
| parameters | iFlex 1500A, I17XX-FLEX1500 18 | iFlex 3000A, I17XX-FLEX3000 | iFlex 6000A, I17XX-FLEX6000 |
|---|---|---|---|
| Power range W, VA, var | 150 A/1500 A | 300 A/3000 A | 600 A/6000 A |
| 150 kW/1.5 MW | 300 kW/3 MW | 600 kW/6 MW | |
| Maximum resolution W, VA, var | 0.1 kW/1kW | 1 kW/10 kW | 1 kW/10k W |
| parameters | I17XX-FLEX1500 18 | I17XX-FLEX3000 | I17XX-FLEX6000 | |
|---|---|---|---|---|
| Active power P | PF ≥ 0.99 | 150 A/1500 A | 300 A/3000 A | 600/6000A |
| 1.2 % + 0.005 % | 1.2 % + 0.0075 % | 1.7 % + 0.0075 % | ||
| Active electrical energy Ea | 0.1 ≤ PF < 0.99 | (1.2+√(1-PF)2)/(2 PF)) % + 0.005 % | (1.2+√(1-PF)2)/(2 PF)) % + 0.0075 % | (1.7+√(1-PF)2)/(2 PF)) % + 0.0075 % |
| Apparent power S Apparent energy Eap |
0 ≤ PF ≤ 1 | 1.2 % + 0.005 % | 1.2 % + 0.0075 % | 1.7 % + 0.0075 % |
| Reactive power Q Reactive energy Er |
0 ≤ PF ≤ 1 | Measured apparent power/electrical energy 2.5% | ||
| Additional uncertainties (Power high range %) |
VP-N > 250 V | 0.02 % | 0.02 % | 0.02 % |
| Phase (voltage to current) | - | 0.28° | 0.28° | 0.28° |
| 1 Nominal voltage in the range of 100 V to 690 V; also known as Udin.
participation condition Ambient: 23 °C ±5 °C, instrument operated for at least 30 minutes, no external electrical/magnetic fields, relative humidity less than 65 % Input conditions: Cos Φ/PF = 1, sinusoidal signal f = 50/60 Hz, power supply 120 V/230 V ±10 %. Current and power specifications: Input voltage >100V Input Current > 10 % of current range Primary side conductor centered on current clamp or Rogowski coil Temperature coefficient: above 28 °C or below 18 °0.1 x Specified Accuracy per degree Celsius at C |
||||
General technical indicators
| Main features | |
|---|---|
| warranty period | Analyzer: 2 years (excluding batteries) Accessories: 1 year (including batteries) |
| calibration period | 2 years |
| Dimensions (L x W x H) | 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in) |
| weights | 2.1 kg (4.6 lb) |
| anti-theft protection | Slots for Kensington Anti-theft Locks |
| Environmental parameters | |
|---|---|
| Operating Temperature Range | -10 °C to 50 °C |
| Storage temperature range | -20 °C to 60 °C |
| Operating humidity | IEC 60721-3-3: 3K5 (Revised): -10 °C to 30 °C: ≤95 %, no condensation or ice 35 °C: 70 % 40 °C: 55 % 50 °C: 35 % |
| IP rating | IEC 60529: IP50 |
| vibratory | IEC 60721-3-3 / 3M2 |
| power supply | |
|---|---|
| voltage range | 100 V - 600 V -15 %/+10 % (85 V ... 660 V) |
| power wastage | 40 VA max. |
| power frequency | 50/60 Hz (42.5 Hz ... 69 Hz) |
| uninterruptible power supply | Lithium-ion battery BP1770 with greater temperature range, customer replaceable Battery-powered runtime: 1.5 hours |
| safety | |
|---|---|
| General Information | IEC 61010-1: Contamination class 2 |
| power supply | Overvoltage CAT IV 600 V With power adapter MA-C8: overvoltage CAT II 300 V |
| surveying | IEC 61010-2-030: CAT IV 600 V, CAT III 1000 V |
| Altitude 2000 m to 4000 m | Reduction to: Power supply: CAT IV 300 V With MA-C8 adapter: CAT II 150 V Measurements: CAT IV 300 V, CAT III 600 V, CAT II 1000 V |
Model: Fluke 1770 Series Three-Phase Power Quality Analyzer
Fluke 1773 Power Quality Analyzer
FLUKE-1773, POWER QUALITY ANALYZER
Package included
- FLUKE-1773 Power Quality Analyzer
- I17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) Current Probe (Set of 4)
- FLUKE-17XX Flat Cable Voltage Test Leads, 3 Phase + Zero Wire
- AC285 Black Alligator Clips (Set of 4)
- AC285 Green Alligator Clip
- 1M USB-C Black Cable
- Power cords (US, EU, UK, Australia, Brazil)
- FLK-17XX 0.18M Test Lead Set
- Green Test Leads
- Cable marking kit (for voltage and current)
- FLUKE-174X-MA-C8 Wall Socket Adapter
Fluke 1773/Basic Power Quality Analyzer (no probe)
FLUKE-1773/BASIC Power Quality Analyzer
Package included
- FLUKE-1773 Power Quality Analyzer
- FLUKE-17XX Flat Cable Voltage Test Leads, 3 Phase + Zero Wire
- AC285 Black Alligator Clips (Set of 4)
- AC285 Green Alligator Clip
- 1M USB-C Black Cable
- Power cords (US, EU, UK, Australia, Brazil)
- FLK-17XX 0.18M Test Lead Set
- Green Test Leads
- Cable marking kit (for voltage and current)
- FLUKE-174X-MA-C8 Wall Socket Adapter
Fluke 1775 Power Quality Analyzer
FLUKE-1775, power quality analyzer
Package included
- FLUKE-1775 Power Quality Analyzer
- I17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) Current Probe (Set of 4)
- FLUKE-17XX Flat Cable Voltage Test Leads, 3 Phase + Zero Wire
- AC285 Black Alligator Clips (Set of 4)
- AC285 Green Alligator Clip
- 1m USB-C Black Cable
- power cable (of an appliance etc)
- FLK-17XX 0.18M Test Lead Set
- Green Test Leads
- MP1-3R/1B Magnetic Probe Kit
- FLUKE-174X-HANGER Magnetic Suspension Kit
- FLUKE-177X-4204, WI-FI/BLE Module
- Cable marking kit (for voltage and current)
- FLUKE-174X-MA-C8 Wall Socket Adapter
- black soft cover
Fluke 1775/Basic Power Quality Analyzer (no probe)
FLUKE-1775/BASIC Power Quality Analyzer
Package included
- FLUKE-1775 Power Quality Analyzer
- FLUKE-17XX Flat Cable Voltage Test Leads, 3 Phase + Zero Wire
- AC285 Black Alligator Clip
- AC285 Green Alligator Clip
- 1m USB-C Black Cable
- power cable (of an appliance etc)
- FLK-17XX 0.18M Test Lead Set
- Green Test Leads
- Cable marking kit (for voltage and current)
- FLUKE-174X-MA-C8 Wall Socket Adapter
- black soft cover
Fluke 1777 Power Quality Analyzer
FLUKE-1777, Power Quality Analyzer
Package included
- FLUKE-1777 Power Quality Analyzer
- I17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) Current Probe
- FLUKE-17XX Flat Cable Voltage Test Leads, 3 Phase + Zero Wire
- AC285 Black Alligator Clip
- AC285 Green Alligator Clip
- 1m USB-C Black Cable
- power cable (of an appliance etc)
- FLK-17XX 0.18M Test Lead Set
- Green Test Leads
- MP1-3R/1B Magnetic Probe Kit
- FLUKE-174X-HANGER Magnetic Suspension Kit
- FLUKE-177X-4204, WI-FI/BLE Module
- Cable marking kit (for voltage and current)
- FLUKE-174X-MA-C8 Wall Socket Adapter
- FLUKE-1777 HARDCASE Hard Rolling Case
Fluke 1777/Basic Power Quality Analyzer (no probe)
FLUKE-1777/BASIC Power Quality Analyzer
Package included
- FLUKE-1777 Power Quality Analyzer
- FLUKE-17XX Flat Cable Voltage Test Leads, 3 Phase + Zero Wire
- AC285 Black Alligator Clip
- AC285 Green Alligator Clip
- 1m USB-C Black Cable
- power cable (of an appliance etc)
- FLK-17XX 0.18M Test Lead Set
- Green Test Leads
- Cable marking kit (for voltage and current)
- FLUKE-174X-MA-C8 Socket Adapter
- FLUKE-1777 HARDCASE Hard Rolling Case