How to use VNA?

common problems 3820

Vector network analyzers measure a wide variety of devices and networks and offer a wide range of measurements for a variety of usage scenarios, such as spectrum analysis, pulse measurements, power amplifier (PA) characterization, and active device testing.

The following guide describes how to set up network analyzer measurements, calibrate the measurement system, and interpret measurement results:

Performing Measurements with a Vector Network Analyzer

The uses of the VAN are so extensive that each measurement is sufficiently well-described to construct a separate website; however, we will look at how the fundamentals discussed here apply to each measurement.

Step 1: Setting up your measurements

The VNA can perform all types of measurements, but you usually need to set up certain types of sweeps. The main parameters of a sweep are the start and end frequencies, power, and IF bandwidth.

Start frequency and end frequency

  • These values determine the boundaries of the frequency sweep
  • Select the value that fully captures the behavior of the device
  • If you know where the center of the measurement will be, set the center frequency and sweep width accordingly.

power supply

  • This value determines the power level of the test signal that will be sent to the device under test
  • For passive devices (e.g., filters), use the maximum source power
  • For active devices, the power needs to be limited to avoid creating compression on the device under test or the VNA.
  • Set a relatively high power level in order to improve the signal-to-noise ratio

IF bandwidth

  • Selection of the required resolution bandwidth based on acceptable measurement speeds
  • Higher measurement resolution can be achieved by using a smaller IF bandwidth; however, this has the disadvantage of slowing down the measurement speed.
Measurement Setup

Step 2: Calibration

Calibration is a necessary prerequisite for accurate measurements, but first, you need to test your measuring device.

The steps are as follows:

  1. Connect your device and perform uncalibrated measurements.
  2. Adjust the frequency range and IF bandwidth to confirm that you can capture everything you need to see.
  3. Verify that the calibration kit has the same connector type and gender as the device under test.
  4. Connect the calibration kit to your measurement device to perform calibration.
  5. When calibration is complete, everything is ready; you can reconnect the device under test at any time.
  6. If you change the frequency range or IF bandwidth, you will need to recalibrate.

Tips:Use a torque wrench to make the connection in order to secure the contact points between the individual conductors without damaging them. Turn only the nut on the connector; avoid twisting the conductors against each other.

Network Analyzer Calibration for accurate test and measurement results

Step 3: Interpreting the results

The VNA has a number of software tools to help you analyze your measurements, such as a 3 dB bandwidth cursor, a time domain analysis function, and more. Choosing the right software and features can make your analysis easier.

Highly integrated network analyzers such as the PNA can be equipped with dozens of applications to perform challenging measurements such as nonlinear measurements and active device characterization.

Network Analyzer Software

Vector Network Analyzer Applications

Vector network analyzers are incredibly versatile instruments. Here are some examples of their applications.

spectral analysis

Adding spectrum analysis to a network analyzer can dramatically reduce test time by, for example, speeding up burr searches, eliminating inter-instrument switching, and taking full advantage of the "Single Connection, Multiple Measurements (SCCM)" feature.

Network analyzer performs spectrum analysis
The SCCM window contains spectrum analysis and network analysis measurements.

pulse measurement

In standard operation, network analyzers use a continuous wave (CW) signal. This is useful for many applications, and many specific scenarios prioritize pulsed RF signals, for example:

  • Testing antennas designed for pulsed mode of operation
  • On-chip measurements that require attention to the heating of continuous wave signals
  • Time Domain Reflectometer (TDR)

Advanced network analyzers such as PNAs can help perform pulse-RF measurements for many applications.

On-Wafer Test Setup for Pulsed Measurement
On-chip test set

Active Component Testing

Modern RF systems are filled with active devices such as amplifiers, mixers, and frequency converters. In the past, testing these types of devices usually required an entire rack of equipment. Today, network analyzers are sufficient to characterize active devices with great precision without the need for additional hardware.

By integrating all measurements into a single instrument, a network analyzer can replace a traditional RF system, thereby dramatically reducing test time. With an integrated network analyzer, such as the PNA, you can test:

  • S Parameter
  • Nonlinear parameters (X-parameters)
  • Gain compression
  • Intermodulation Distortion (IMD)
  • spurious signal
  • coefficient of noise

And more.

gain compression graph with idea linear transfer function
Gain compression applications

Previous. NEXT STORY.

Recommended

  • How do I measure the current?

    470

    Why do you need to measure current? In this article, we will cover the reasons for measuring current, how to measure current and what to look for when measuring current. We cannot see the current that is flowing with our own eyes. Therefore, specialized measuring instruments are needed to measure current and other parameters. But why do we need to measure current? And how should we measure it? This article will detail the reasons for the need to measure current...

    View Full Version
  • What can a signal analyzer do?

    533

    Signal analyzers are capable of measuring the amplitude and phase of an input signal at a single frequency. The Signal Analyzer combines the large dynamic range of a swept-tuned spectrum analyzer with the power of a Vector Signal Analyzer (VSA) to perform in-channel measurements, such as Error Vector Magnitude (EVM) measurements, which require both magnitude and phase information. The VSAs are available in a wide range of sizes and sizes.

    View Full Version
  • What is a digital multimeter?

    448

    A multimeter is an instrument that can measure a wide range of parameters, such as alternating (AC) or direct current (DC) voltage, AC or DC current, resistance, temperature, capacitance, and so on. Modern digital multimeters use digital and logic technology to become smaller and smaller with more and more built-in functions. By introducing digital technology, digital multimeters can provide graphical displays, data logging and signal digitization as well as...

    View Full Version
  • What is the purpose of an oscilloscope?

    219

    Test engineers and developers use oscilloscopes to display, visualize graphs, and analyze electrical signals during research and development, verification, quality assurance, and troubleshooting or debugging of electronic systems, boards, and integrated circuits. Oscilloscopes play a key role in a variety of applications and technologies across all industries, including high-speed digital electronics, optical communications, RF, power electronics, automotive and aerospace...

    View Full Version

Hello!sign in

Click to cancel reply
    Expand More

    Product consultation and purchase:18218718851

    I already understand