Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders
Fluke 1736 and 1738 Three-Phase Power Quality Recorders

Fluke 1736 and 1738 Three-Phase Power Quality Recorders

Main characteristics

The Fluke 1736 and 1738 Three-Phase Power Quality Recorders are versatile, Fluke Connect-compatible, three-phase power recorders for performing energy, load and power quality studies.

  • Primary Measurement:Automatically captures and records voltage, current, power, harmonics, and associated power quality values, and captures dips, rises, and inrush currents using snapshots of event waveforms and high-resolution true RMS profiles
  • The instrument is easily powered:Power supply to the instrument directly from the measurement circuit
  • Energy Analyze Plus application software:Download and analyze every detail of energy consumption and power quality health with our automated reporting capabilities and use the integrated power quality health summary to get a quick snapshot of system health

SKU:Fluke 1736 Category. Brand.

Inquire about this product

Product Overview: Fluke 1736 and 1738 Three-Phase Power Quality Recorders

The Fluke 1736 and 1738 three-phase power quality recorders feature Fluke Connect® mobile app and desktop software compatibility, giving you the data you need to make important power quality and energy consumption decisions in real time. 1736 and 1738 perform energy analysis and basic power quality logging, making them the ideal test tools for automatically acquiring and logging more than 500 power quality parameters, giving you better visibility into the data you need to optimize system reliability and save money. The 1736 and 1738 are ideal for power analysis and basic power quality logging, automatically acquiring and logging over 500 power quality parameters, giving you better visibility into the data you need to optimize system reliability and save money. With the Fluke 1738 Advanced Power Quality Recorder, you can perform advanced analysis using the enhanced Power Quality Health Profile (EN50160) feature, giving you a quick overview of the overall health of your electrical system. The Power Quality Health Profile is an evaluation of recorded data based on detailed power quality measurements, including visual event waveform capture, giving you better visibility into the data you need to optimize system reliability and save money.

With an optimized user interface, flexible current probes, and intelligent measurement verification, you can reduce measurement errors by verifying and correcting common connection errors, making setup easier than ever and reducing measurement uncertainty. Remote access to data and sharing with your team through the Fluke Connect® app lets you maintain a safer working distance and make important decisions in real time, reducing the need for protective gear and field visits. You can also use the included Fluke Energy Analyze Plus software package to easily graph your measurements, help identify problems and create detailed reports. As an optional feature, you can also create IEEE519 reports that provide insight into harmonic levels, voltage/current distortion, and load current (license required).

Other useful features:

  • Data is available on loggers, the Fluke Connect mobile app and desktop software, or through your facility's Wi-Fi infrastructure.
  • Measurement of all 3-phase and neutral wires with the supplied 4 flexible current probes
  • Power supply to the instrument directly from the measurement circuit
  • Check measured values during recording sessions and before downloading for real-time analysis
  • 1738 includes event waveform snapshots and high-resolution true RMS profiles, as well as date, time stamp, and severity to capture transient drops, transient rises, and inrush currents and help identify potential causes of power quality problems
  • 1738 also provides a snapshot of the overall health of the electrical system through a power quality health profile
  • Provides a bright color touchscreen display for easy on-site analysis and data checking
  • Helps you always capture the right data with a fast, guided graphical user interface
  • Reduce connection uncertainty with intelligent verification features
  • Allows you to complete field setup from the front panel or the Fluke Connect app on your smartphone
  • Provides fully integrated logging with other Fluke Connect-enabled devices for simultaneous logging of up to two additional measurement parameters* on a Fluke Connect wireless digital multimeter or module
  • Energy Analyze Plus application software is included, enabling you to analyze every detail of your energy consumption and power quality health and create automated reports

Record the most common parameters

The Models 1736 and 1738 are designed to measure the most critical three-phase power parameters, simultaneously recording rms voltage, rms current, voltage and current events, voltage and current THD, voltage and current harmonics up to the 50th harmonic, active power, reactive power, power factor, active energy, reactive energy, and more. More than a year's worth of data logging can identify problems that may have been missed or difficult to detect.

Analysis and reporting

Getting logged data is only part of the job. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers, and Fluke Energy Analyze Plus software makes this easy. With powerful analysis tools, customized reports can be created in minutes, allowing you to communicate findings and quickly resolve issues, so you can optimize system reliability and save money.

Product Specifications: Fluke 1736 and 1738 Three-Phase Power Quality Recorders

Technical indicators
accurate
parameters range (of scales or measuring equipment) resolution (of a photo) Basic accuracy at reference conditions (% reading + % full scale)
input voltage 1000 V 0.1 V ±(0.2% + 0.01%)
Current: DC input i17xx-flex 1500 12" 150 A 0.1 A ±(1% + 0.02%)
1500 A 1 A ±(1% + 0.02%)
i17xx-flex 3000 24" 300 A 1 A ±(1% + 0.03%)
3000 A 10 A ±(1% + 0.03%)
i17xx-flex 6000 36" 600 A 1 A ±(1.5% + 0.03%)
6000 A 10 A ±(1.5% + 0.03%)
i40s-EL Current Clamp 4 A 1 mA ±(0.7% + 0.02%)
40 A 10 mA ±(0.7% + 0.02%)
frequency 42.5 Hz to 69 Hz 0.01 Hz ± (0.1%)
auxiliary input ±10 V dc 0.1 mV ±(0.2% + 0.02%)
Voltage min/max 1000 V 0.1 V ±(1% + 0.1%)
Current min/max Determined by current probe Determined by current probe ±(5% + 0.2%)
Voltage THD 1000% 0.1% ±0.5
Current THD 1000% 0.1% ±0.5
2nd to 50th voltage harmonics 1000 V 0.1 V ≥ 10 V: ±5% of reading
< 10 V: ± 0.5 V
2 to 50th current harmonics Determined by current probe Determined by current probe ≥ 3% of current range: ±5% of reading
< 3% of current range: ± 0.15% of range
Unbalance 100% 0.1% ±0.2
Inherent Uncertainty ± (% of reading + % of range)¹
parameters magnitude of impact iFlex 1500-12 iFlex 3000-24 iFlex 6000-36 i40S-EL
150 A/1500 A 300 A/3000 A 600 A/6000 A 4 A/40 A
Active power P PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Active energy Ea PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent power S 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent energy Eap 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Reactive power Q 0 ≤ PF ≤ 1 2.5% of measured apparent power
Reactive energy Er 0 ≤ PF ≤ 1 2.5% of measured apparent power
Power factor PF - ±0.025
Displacement power factor - ±0.025
DBF/cosϕ - ±0.025
Additional uncertainty in range¹ VP-N>250 V 0.015% 0.0225% 0.0225% 0.015%
¹Range = 1000 V x Irange
Reference conditions:

  • Environment:23 °C ±5 °C, instrument operated for at least 30 minutes, no external electrical/magnetic fields, relative humidity less than 65%
  • Input conditions:CosΦ/PF=1, sinusoidal signal f=50/60 Hz, power supply 120 V/230 V ±10%.
  • Current and power specifications:Input voltage 1 ph: 120 V/230 V or 3 ph star/delta: 230 V/400 V Input current: I > 10% of current range
  • Primary conductor centered on current clamp or Rogowski coil
  • Temperature coefficient:Increase the specified accuracy by 0.1 times in Celsius above 28 °C or below 18 °C
Electrical specifications
power supply
Voltage range 100 V to 500 V when supplied via the measuring circuit with a safe input plug
100 V to 240 V with standard power cord (IEC 60320 C7)
power wastage 50 VA maximum (15 VA maximum with IEC 60320 input)
efficiencies ≥ 68.2% (energy efficiency code compliant)
Maximum no-load loss < 0.3 W (only when using IEC 60320 inputs)
Mains frequency 50/60 Hz ±15%
batteries Lithium-ion battery 3.7 V, 9.25 Wh (customer replaceable)
Battery powered runtime 4 hours in standard operating mode, up to 5.5 hours in power saving mode
charging time < 6 hours
data acquisition
resolution (of a photo) 16-bit synchronized sampling
sampling frequency 10.24 kHz at 50/60 Hz, synchronized to power supply frequency
Input Signal Frequency 50/60 Hz (42.5 to 69 Hz)
Type of wiring method 1-φ, 1-φ IT, split-phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balance, 3-φ Aron/Blondel (two-meter method), 3-φ open-leg delta, current only (load analysis)
data storage Internal flash memory (not user replaceable)
Memory capacity Typical: 10 logged sessions of 8 weeks, 1 minute intervals, and 500 events¹.
¹The number of possible logging sessions and logging periods depends on the user's needs.
fundamental interval
Parameters measured Voltage, Current, Aux, Frequency, THD V, THD A, Power, Power Factor, Base Wave Power, DPF, Electrical Energy
Average interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Average time min/max Voltage, current: full cycle RMS updated every half cycle (URMS1/2 compliant with IEC61000-4-30 Aux, power: 200ms)
Demand interval (energy meter mode)
Parameters measured Electrical energy (Wh, varh, VAh), PF, maximum demand, cost of electrical energy
intervals User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, Off
Power quality measurements
Parameters measured Voltage, frequency, unbalance, voltage harmonics, THD V, current harmonics, THD A, TDD
Average interval 10 min (mV)
subharmonic 2nd to 50th harmonic
THD Calculated at 50th harmonic
event Voltage: transient drop, transient rise, interruption, Current: inrush current
trigger record Full peripheral voltage and current RMS updated every half cycle (Urms1/2 in accordance with IEC61000-4-30)
Voltage and Current Waveforms (1738)
standards-compliant
harmonic (wave with frequency an integer multiple of the fundamental) IEC 61000-4-7: Class 1
IEEE 519 (short time harmonics)
power quality IEC 61000-4-30 Class S, IEC 62586-1 (PQI-S devices)
power supply IEEE 1459
Power quality compliance EN50160 (for measuring parameters)
connector
USB-A File transfer, firmware update via USB flash memory
Maximum current: 120 mA
WiFi File transfer and remote control via direct connection or WiFi network
bluetooth Reading Auxiliary Measurement Data from Fluke Connect® 3000 Series Modules (requires 1738 or 1736 upgrade option)
USB-mini Download data to PC
Voltage Input
Number of inputs 4 (three-phase and zero line)
Maximum input phase voltage 1000 Vrms, CF 1.7
Input Impedance 10 MΩ
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
resizing 1:1, variable
Measurement category 1000 V CAT III/600 V CAT IV
Current Input
Number of inputs 4, automatic selection of connected sensor mode
Input Voltage Current clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski Roche Coil Input 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; crest factor 4; all within probe rated range
range (of scales or measuring equipment) Using the Fine Flex Current Probe i17XX-flex1500 12" for 1 A to 150 A/10 A to 1500 A
3 A to 300 A/30 A to 3000 A with the i17XX-flex3000 24" Fine Flex Current Probe
6 A to 600 A/60 A to 6000 A with the i17XX-flex6000 36" Fine Flex Current Probe
40 mA to 4 A/0.4 A to 40 A (40 A Current Clamp i40s-EL)
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
resizing 1:1, variable
auxiliary input
Number of inputs 2
Input Range 0 to ± 10 VDC, 1 reading/second
proportionality factor Format: mx + b (gain and offset) user configurable
Displayed units User configurable (7 characters, e.g. °C, psi or m/s)
wireless connection
Number of inputs 2
Supported Modules Fluke Connect® 3000 Series
harvest 1 reading/second
Environmental parameters
operating temperature -10 °C to +50 °C (14 °F to 122 °F)
storage temperature -20 °C to +60 °C (-4 °F to 140 °F) with battery: -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity 10 °C to 30 °C (50 °F to 86 °F) Maximum Relative Humidity 95%
30 °C to 40 °C (86 °F to 104 °F) Maximum 75% Relative Humidity
40 °C to 50 °C (104 °F to 122 °F) Maximum 45% Relative Humidity
Working altitude 2000 m (down to 1000 V CAT II/600 V CAT III/300 V CAT IV for up to 4000 m)
Storage altitude 12,000m
housings IP50 (in accordance with EN60529)
vibratory MIL-T-28800E, Type 3, Class III, Type B
safety IEC 61010-1
IEC power input: overvoltage category II, pollution class 2
Voltage terminals: Overvoltage category IV, pollution class 2
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
electromagnetic compatibility EN 61326-1: Industry CISPR 11: Group 1, Class A
Korea (KCC): Class A equipment (industrial broadcasting and communications equipment)
United States (FCC): 47 CFR 15 Subpart B. This product is considered duty-free equipment under Section 15.103.
temperature coefficient 0.1 x accuracy index/°C
General technical indicators
Color LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch screen
warranty period Instrument and power supply: two years (excluding batteries)
Accessories: one year
Calibration cycle: two years
sizes Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
Instrument (with power supply): 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)
weights Instrument: 1.1 kg (2.5 lb)
Power: 400 g (0.9 lb)
tamper-proof Anti-theft lock slot
i17xx-flex 1500 12" Flexible Current Probe Specifications
measuring range 1 to 150 A AC / 10 to 1500 A AC
lossless current 100 kA (50/60 Hz)
Inherent error at reference conditions* ±0.7% of reading
173x + iFlex Accuracy ± (1% of reading + 0.02% of range)
Temperature coefficients beyond the operating temperature range 0.05%/°C of reading, 0.09%/°F of reading
operating voltage 1000 V CAT III, 600 V CAT IV
Probe cable length 305 mm (12 in)
Probe Cable Diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Output cable length 2 m (6.6 ft)
weights 115 g
Probe Cable Material TPR
Connector Material POM + ABS/PC
output cable TPR/PVC
operating temperature Tested at a wire temperature of -20 °C to +70 °C (-4 °F to 158 °F), not exceeding 80 °C (176 °F)
Non-operating temperature -40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity in working condition 15% to 85% Non-Condensing
IP rating IEC 60529:IP50
warranty period 1 year
* Reference conditions:

  • Ambient: 23 °C ±5 °C, no external electric/magnetic fields, relative humidity 65%
  • Primary side conductor at center

Model: Fluke 1736 and 1738 Three-Phase Power Quality Recorders

Fluke 1738/B

Portable advanced power quality recorder (excluding current probe)

Included:

  • Fluke 1738 Instrument
  • Voltage test lead set
  • Alligator Clips (4x)
  • Soft Carrying Case
  • Energy Analyze Plus Software
  • power cable (of an appliance etc)
  • color code cluster
Fluke 1738/EUS

Portable Advanced Power Quality Recorder Euro/American Version

Included:

  • Fluke 1738 Instrument
  • Voltage test lead set
  • Alligator Clips (4x)
  • 12 in. 1,500A Flexible Current Probe (4x)
  • Soft Carrying Case
  • Energy Analyze Plus Software
  • Wi-Fi adapter
  • Bluetooth adapter
  • power cable (of an appliance etc)
  • color code cluster
Fluke 1738/INTL

Portable Advanced Power Quality Recorder International Edition

Included:

  • Fluke 1738 Instrument
  • Voltage test lead set
  • Alligator Clips (4x)
  • 12 in. 1,500A Flexible Current Probe (4x)
  • Soft Carrying Case
  • Energy Analyze Plus Software
  • power cable (of an appliance etc)
  • color code cluster
Fluke 1736/B

Portable power quality recorders (excluding current probes)

Included:

  • Fluke 1736 Instrument
  • Voltage test lead set
  • Alligator Clips (4x)
  • Soft Carrying Case
  • Energy Analyze Plus Software
  • power cable (of an appliance etc)
  • color code cluster
Fluke 1736/EUS

Portable Power Quality Recorder Euro/American Version

Included:

  • Fluke 1736 Instrument
  • Voltage test lead set
  • Alligator Clips (4x)
  • 12 in. 1,500A Flexible Current Probe (4x)
  • Soft Carrying Case
  • Energy Analyze Plus Software
  • Wi-Fi adapter
  • Bluetooth adapter
  • power cable (of an appliance etc)
  • color code cluster
Fluke 1736/INTL

Portable Power Quality Recorder International Edition

Included:

  • Fluke 1736 Instrument
  • Voltage test lead set
  • Alligator Clips (4x)
  • 12 in. 1,500A Flexible Current Probe (4x)
  • Soft Carrying Case
  • Energy Analyze Plus Software
  • power cable (of an appliance etc)
  • color code cluster