Scope of Application
Miniature AC vibration motors, etc.
Technical indicators
model number | ZC1681B-M | |
Maximum number of accessible channels | 20 channels, divided into two groups, channel 1~10 is one group, channel 11~20 is another group, each group of test parameters (including signal type) can be set independently.
Voltage per channel can be automatically corrected. |
|
Test signal type | Built-in dual-channel sine wave fixed frequency/sweep generator, dual-channel SD player, external signal.
Adaptation to motor test requirements under different reference standards |
|
Aging test time | 0000:00:00 ~ 9999:59:59, large 9999h, can be set arbitrarily | |
Channel Management | Each channel can start, stop or continue the relevant test at any time | |
Real-time monitoring function | 20-channel simultaneous monitoring, each channel can be timed to capture the product F0 and drive with F0 (drive signal is pure sine wave), can monitor the product F0 every other time period
Monitoring F0 in the frequency range of 50 Hz to 350 Hz If F0 is detected as abnormal, the signal output of this channel is stopped in time. |
|
Channel trimming function | Independence between channels can be realized, and each voltage can be individually fine-tuned for voltage and fine-tuned for frequency captured to F0. | |
warning of malfunction | The 20 LEDs on the panel show the location of the fault channel and the cause of the fault is displayed on the screen at the same time. | |
user interface | 7-inch color LCD display, touch screen + keyboard shortcut input, Chinese interface | |
Line Output Connection | Attenuator-adjusted signal output for connection to external power amplifiers without volume control or external digital filters | |
Signal Access Connection | Access to customized test signals |