-10:1 CT ratio outputs a high current of 1000A continuous AC (1500A for 5 minutes).
-Expands the measurement range of a typical clamp meter
-Expanded measuring range for current clamps with good phase characteristics
Basic parameters
| Rated Input Current | 1000 A continuous (max. 1500 A within 5 minutes) |
|---|---|
| Rated output current | AC 100A (CT ratio 10 : 1) |
| Amplitude accuracy | ±1.5 % rdg. |
| Phase accuracy | ±1.0° or less |
| frequency characteristic | Amplitude. ±2.0 % rdg. at 20Hz to 5kHz (deviation from accuracy) Phase. ±1.0 % rdg. at 20Hz to 5kHz (deviation from accuracy) |
| Maximum circuit voltage | AC 600 V rms (insulated leads) |
| Measurable wire diameter | Diameter up to 55 mm or 80 mm wide rows |
| Volume and weight | 99.5mmW x 188mmH x 42mmD, 580g, cable length 3m |
| attachment (email) | Marking tape x 6 |
※ General-purpose clamp CT 9279 cannot be used.
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.