-Pen multimeter with integrated test lead and main unit
-Overvoltage protection up to AC 600V for resistance/conductance ranges.
-Probe winding and illumination of the measurement object, etc.
Accuracy of the DMM
The DMM is described as a representative value for the basic accuracy due to the large number of measurement functions and ranges.
Refer to the sample PDF for the accuracy of each range.
Basic parameters
| DC voltage | 419.9mV~600V, 5 ranges, basic accuracy: ±1.3%rdg. ±4dgt. |
|---|---|
| AC Voltage/50~500Hz | 4.199V~600V, 4 steps range Basic accuracy: ±2.3%rdg. ±8dgt. (average) |
| resistive | 419.9 Ω~ 41.99 MΩ, 6 ranges, basic accuracy: ±2.0 % rdg. ±4 dgt. |
| conductivity check | Threshold 50Ω ±40Ω |
| Diode check | Clockwise judgment only, open port voltage: 3.4V or less, test current: 800μA or less |
| Automatic power saving function | Yes (can be canceled) |
| demonstrate | Digital/LCD, 4199dgt. max. |
| sampling rate | 2.5 times/s |
| Power supply | Coin cell battery CR2032×1, continuous use time: 150h (when measuring DC voltage), 30h (pen light on for 10 seconds/off for 20 seconds, when measuring DC voltage) |
| Volume and weight | 30W×182H×26.5Dmm, 80g |
| attachment (email) | Instruction manual × 1, Coin lithium battery (CR2032) × 1 (built-in main unit), Sleeve (red/black 1 each) |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.