PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load
PEL-500 Series DC Electronic Load

PEL-500 Series DC Electronic Load

¥999,999.00
  
  • Quantity
    • -
    • +
  •    
Inquire about this product
  • 5-digit voltage, current and power display
  • Simultaneously display voltage value, current value, power
  • Short circuit time can be set during short circuit test
  • Automatic test function for overcurrent protection/overpower protection
  • Battery discharge test function can set the discharge stop voltage (Vbatt), discharge capacity (AH, WH) and discharge stop time.
  • The Surge test simulates the power-on overbalance current and the thermal insertion instantaneous current.
  • Constant Current, Constant Resistance, Constant Voltage, Constant Power and Dynamic Mode
  • Over-voltage, over-current, over-power, over-temperature protection and reverse polarity detection
  • The voltage polarity display can be set to positive ("+") or negative ("-").
  • Communication interface: RS-232C, USB

PEL-500 series single-channel electronic load, a total of five models respectively provide 0 ~ 80V / O - 500V voltage operating range and 250 ~ 700W power operating range. The PEL-500 series can be used in R&D, QC, ATE systems and production testing, including voltage/current source testing, switching power supply transient response, constant voltage mode for current limiting testing, and simulation of battery and battery discharge testing.The PEL-500 series provides a 5-digit display for voltage, current and power, allowing the user to monitor the measurement data of the object to be measured at the same time. In order to facilitate the user to evaluate the object to be tested. PEL-500 series provides Surge test, which can simulate the power-on overshoot current and hot-plug instantaneous current. The built-in battery discharge test function allows users to determine the conditions for stopping the discharge according to the test requirements of the object to be tested, including setting the discharge stop voltage (Vbatt), discharge capacity (AH, WH), and discharge stop time. Users can set the loading voltage/unloading voltage of PEL.500 series according to the characteristics of the object to be tested, when the output voltage of the object to be tested rises to the value of loading voltage, loading will start, when the output voltage falls to the unloading voltage, unloading will start. Users can use the GO/NG function to pre-set judgment conditions according to the functions and specifications of the body to be tested, and the PEL.500 series will automatically generate judgment results based on the set judgment conditions during the test. Under the safety test requirements of power supply, PEL-500 series not only provides Short test function, but also provides automatic test function for over-current protection/over-power protection, which simplifies the user's tedious manual operation to verify the OCP/OPP action points of the device to be tested. The resulting measurement results help users to confirm the actual action point of the OCP/OPP of the object to be tested is within the measurement specifications.PEL-500 series can provide load current waveforms to the oscilloscope via the BNC output terminal of the Imonitor; it also provides over-voltage, over-current, over-power and over-temperature protection, and reverse polarity detection, and when any one of them generates a triggering action, the PEL-500 series will have protection for the over-voltage, over-current, over-power and over-temperature protection. The PEL-500 series will have protection or alert measures to protect the PEL-500 series from damage due to abnormal operation of the scope.

model number PEL-503-80-50 PEL-504-80-70 PEL-504-500-15 PEL-507-80-140 PEL-507-500-30
Scope of work
Power (W) 250 W 350 W 350 W 700 W 700 W
Current (A) 50 A 70 A 15 A 140 A 30 A
Voltage (V) 80 V 80 V 500 V 80 V 500 V
Minimum operating voltage 1.0V @ 50A 1.2V @ 70A 6V @ 15A 0.9V @ 140A 3.0V @ 30A
protective function
Over Power Protection (OPP) ≈262.5 W ≈367.5 W ≈367.5 W ≈735 W ≈ 735 W
Overcurrent protection (OCP) ≈52.5 A ≈73.5 A ≈15.75 A ≈147 A ≈31.5 A
Overvoltage protection (OVP) ≈84 V ≈84 V ≈525 V ≈84 V ≈ 525 V
Over Thermal Protection (OTP) YES YES YES YES YES
operating mode
Constant current mode realm 0 to 5.04 to 50.4 A 0 to 7.02 to 70.2 A 0 to 1.5 to 15 A 0 to 14.04 to 140.4 A 0 to 3 to 30 A
resolution (of a photo) 0.084 mA / 84 mA 0.117 mA / 1.17 mA 0.025 mA / 0.25 mA 0.234 mA / 2.34 mA 0.05 mA / 0.5 mA
accurate ±0.1% OF (SETTING + RANGE) ±0.1% OF (SETTING + RANGE) ±0.1% OF (SETTING + RANGE) ±0.1% OF (SETTING + RANGE) ±0.1% OF (SETTING + RANGE)
Constant Resistance Mode realm 0.016~1.6~96000 Ω 0.0114~1.14~68400 Ω 0.4~40~2400000 Ω 0.0057~0.57~34200 Ω 0.2~20~1200000 Ω
resolution (of a photo) 26.666 μΩ / 0.010416 mSiemens 19 μΩ / 0.014619 mSiemens 666.667uΩ / 0.416 uSiemens 9.5uΩ / 29.239 uSiemens 333.334uΩ / 0.833 uSiemens
accurate ±0.2% OF (SETTING + RANGE) ±0.2% OF (SETTING + RANGE) ±0.2% OF (SETTING + RANGE) ±0.2% OF (SETTING + RANGE) ±0.2% OF (SETTING + RANGE)
Constant Voltage Mode realm 0 to 8.1 to 81 V 0 to 8.1 to 81 V 0~60~500 V 0 to 8.1 to 81 V 0~60~500 V
resolution (of a photo) 0.135mV/ 1.35mV 0.135mV/ 1.35mV 1 mV/ 10mV 0.135mV/ 1.35mV 1 mV/ 10mV
accurate ±0.05% OF (SETTING + RANGE) ±0.05% OF (SETTING + RANGE) ±0.05% OF (SETTING + RANGE) ±0.05% OF (SETTING + RANGE) ±0.05% OF (SETTING + RANGE)
Constant Power Mode realm 0~25.02~250.2 W(Imax.= r1:5A , r2:50A) 0~35.04~350.4W(Imax.= r1:7A , r2:70A) 0~35.04~350.4 W (Imax.= r1:1.5A , r2:15A) 0~70.02~700.2 W(Imax.= r1:14A , r2:140A) 0~70.02~700.2 W(Imax.= r1:3A , r2:30A)
resolution (of a photo) 0.417 mW/ 4.17 mW 0.584 mW/ 5.84 mW 0.584 mW/ 5.84 mW 1.167 mW/ 11.67 mW 1.17 mW/ 117 mW
accurate ±0.5% OF (SETTING + RANGE) ±0.5% OF (SETTING + RANGE) ±0.5% OF (SETTING + RANGE) ±0.5% OF (SETTING + RANGE) ±0.5% OF (SETTING + RANGE)
dynamic mode THIGH/TLOW 10 uS to 9.999 Sec 10 uS to 9.999 Sec 10 uS to 9.999 Sec 10 uS to 9.999 Sec 10 uS to 9.999 Sec
resolution (of a photo) 0.001 / 0.01 / 0.1 / 1mS 0.001 / 0.01 / 0.1 / 1mS
conversion rate 3.2 to 200 mA/μs 0.032 to 2 A/μS 4.64 to 290 mA/μs 0.0464 to 2.90 A/μS 1 to 62.5 mA/μs 10 to 625 mA/μS 0.0096~0.6A/μs 0.096~6A/μS 2 to 125 mA/μs 20 to 1250 mA/μS
accurate ±5% ±10μS ±5% ±10μS ±5% ±10μS ±5% ±10μS ±5% ±10μS
surveying
Voltage Readback
Range (5 Digital) 0 to 8.1 to 81 V 0 to 8.1 to 81 V 0~60~500 V 0 to 8.1 to 81 V 0~60~500 V
resolution (of a photo) 0.135mV/ 1.35mV 0.135mV/ 1.35mV 1 mV/ 10mV 0.135mV/ 1.35mV 1 mV/ 10mV
accurate ±0.025% OF(READING + RANGE) ±0.025% OF(READING + RANGE) ±0.025% OF(READING + RANGE) ±0.025% OF(READING + RANGE) ±0.025% OF(READING + RANGE)
Current Readback
Range (5 Digital) 0 to 5.04 to 50.4 A 0 to 7.02 to 70.2 A 0 to 1.5 to 15 A 0 to 14.04 to 140.4 A 0 to 3 to 30 A
resolution (of a photo) 0.084 mA / 84 mA 0.117 mA / 1.17 mA 0.025 mA / 0.25 mA 0.234 mA / 2.34 mA 0.05 mA / 0.5 mA
accurate ±0.1% OF (READING + RANGE) ±0.1% OF (READING + RANGE) ±0.1% OF (READING + RANGE) ±0.1% OF (READING + RANGE) ±0.1% OF (READING + RANGE)
power readback
Range (5 Digital) 25W 250W 35W 350W 35W 350W 70W 700W 70W 700W
resolution (of a photo) 0.001W 0.01W 0.001W 0.01W 0.001W 0.01W 0.001W 0.01W 0.001W 0.01W
accurate ± 0.1% of (Reading + Range) ± 0.1% of (Reading + Range)
Surge Test
Surge & Normal Current 0~50A 0~70A 0~15A 0~140A 0~30A
Surge Time 10~1000ms 10~1000ms 10~1000ms 10~1000ms 10~1000ms
Surge Steps 1~5 1~5 1~5 1~5 1~5
Battery Discharge Test
undervoltage protection 0~81V 0~81V 0~500V 0~81V 0~500V
timing 1~99999Sec 1~99999Sec 1~99999Sec 1~99999Sec 1~99999Sec
quantitative (science) 0.1~19999.9AH/0.1~19999.9WH 0.1~19999.9AH/0.1~19999.9WH 0.1~19999.9AH/0.1~19999.9WH 0.1~19999.9AH/0.1~19999.9WH 0.1~19999.9AH/0.1~19999.9WH
other than
Load ON Voltage 0.1 to 25V 0.1 to 25V 0.4 to 100V 0.1 to 25V 0.4 to 100V
accurate 1% of (Setting + Range) 1% of (Setting + Range)
Load OFF Voltage 0 to 25V 0 to 25V 0 to 100V 0 to 25V 0 to 100V
accurate 0.05% of (Setting +Range)  0.05% of (Setting +Range)
Imonitor (non-isolated) 5.04 A/V 7.02 A/V 1.5 A/V 14.04 A/V 3 A/V
Current monitoring FULL SCALE 10V FULL SCALE 10V
accurate 0.5% of (Setting + Range) 0.5% of (Setting + Range)
Typical Short Circuit Resistance 0.018 Ω 0.0169 Ω 0.367Ω 0.0053Ω 0.087Ω
Maximum short-circuit current 50A 70A 15A 140A 30A
connector USB/RS232 USB/RS232
power wastage 40VA 60VA
Dimensions (HxWxD) 205 x 123 x 477mm 205 x 231 x 480mm
weights 5.3Kg 10.3Kg

Optional accessories:

GTL-238 RS-232 Cable, 9 pin,M-F Type,1000mm

GTL-246 USB Cable,1.2m

Ordering Information

PEL-503-80-50 80V, 50A, 250W DC Electronic Load
PEL-504-80-70 80V, 70A, 350W DC Electronic Load
PEL-504-500-15 500V, 15A, 350W DC Electronic Load
PEL-507-80-140 80V, 140A, 700W DC Electronic Load
PEL-507-500-30 500V, 30A, 700W DC Electronic Load

Expand More
PEL-500 Series DC Electronic LoadPEL-500 Series DC Electronic Load
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851