GDM-8352 Digital Multimeter
GDM-8352 Digital Multimeter
GDM-8352 Digital Multimeter
GDM-8352 Digital Multimeter
GDM-8352 Digital Multimeter
GDM-8352 Digital Multimeter

GDM-8352 Digital Multimeter

  • 199999 digits, VFD display
  • Dual measurement/dual display
  • DC Voltage (DCV) Basic Accuracy : 0.012%
  • Selectable measurement speeds up to 320 readings per second
  • True RMS (AC, AC+DC) Measurement
  • Selectable automatic/manual gearshift
  • 12 measurement functions: AC/DC voltage, AC/DC current, AC+DC voltage/current, 2-wire/4-wire resistance, short-circuit buzzer, diode measurement, capacitance, frequency, temperature
  • Multiple auxiliary measurements: Max./Min., REL/REL#, Compare, Hold, dB, dBm, Math (MX+B, %, 1/X)
  • Digital I/O provides dual modes (standard compare and user-defined modes).
  • Standard interface RS-232C and USB device (supports USBBCDC and USBTMC modes)

Categories. , Tags. , Brand.

Inquire about this product

Goodwell introduces the new 5 1/2 Dual Display Digital Meter - GDM-8352, replacing the GDM-8251A and GDM-8351, which also utilizes a VFD dual display, a maximum display of 199999 digits, 0.02% DC voltage basic accuracy, and a USB / RS232C communication interface to provide users with accurate measurement functions, clear numerical observation, and the convenience of linking to a personal computer. interface, providing users with accurate measurement functions, clear numerical observation, and the convenience of easy linkage to a personal computer.

In addition to basic measurements such as AC/DC voltage, AC/DC current, 2-wire/4-wire resistance, temperature measurement, short-circuit beeping and diode test functions, the new meter is equipped with the ability to measure capacitance. A variety of auxiliary functions such as Max/Min, dB, dBm, Compare, Read Hold, Arithmetic (MX+B, 1/X, %), etc. are also provided to assist in meeting the needs of measurement applications such as in-process testing, teaching labs, and inspection situations.

In terms of external control, the pinout of the Digital I/O not only provides the signal outputs commonly used in the comparison function, but also allows users to define the signal outputs of each pin by themselves. In the customization mode, users can treat this I/O as a simple digital hardware and use the signals of each pin to achieve the external control needs, saving users the trouble of creating hardware circuits.

In terms of remote control and data acquisition, considering the user's habitability and the universality of the system interface, the meter provides standard RS-232C and USB interfaces, which can be used to write control programs and read the measurement results; especially on the USB interface, it also allows the user to choose whether the interface is in USBBCDC or USBTMC mode; when the USBTMC mode is selected, the user can control the USB interface instrument just like the GPIB interface instrument, without using the relatively expensive GPIB connection cable. When the USBTMC mode is selected, the user can control the USB interface in the same way as a GPIB interface instrument, without the need to use the relatively expensive GPIB connection cable.

Dual measurement/dual display
Like Goodwell's 6 1/2 and 5 1/2 digit meters, the GDM-8352 utilizes dual VFD displays to support combinations of measurement items, such as monitoring DC voltage and current presented by a component in a test line or measuring DC voltage with an AC component...etc. The results obtained from a single measurement can be presented separately and simultaneously on the individual displays. The results of a single measurement can be presented separately and simultaneously on individual displays. This not only saves the user's time in measurement, but also eliminates the need to switch displays in observation.

Selectable measuring speeds
The GDM-8352 also boasts one of the faster measurement speeds in its class and offers a choice of 3 file speeds - Slow/Medium/Fast; for example, in Fast mode, DC voltage measurements can reach up to 320 readings per second;

Quick Selection

model number sampling rate demonstrate DCV Accuracy temperature function USB storage function Standard Interface
GDM-8352 320/sec 5½ Dual Display (199999) 0.0120% YES YES USB /RS-232
GDM-8341 40/sec 4½ dual display (50000) 0.02% NO NO USB
GDM-8342 40/sec 4½ dual display (50000) 0.02% YES YES USB

 

Detailed specifications

Specification(*1)
Gear(*2) resolution (of a photo) input resistance Accuracy(*3) 1 year (23℃±5℃)
DC voltage
200.000mV 1μV 10MΩ or >10GΩ 0.012+8
2.00000V 10μV 10MΩ or >10GΩ 0.012+5
20.0000V 100μV 11.1MΩ 0.012+5
200.000V 1mV 10.1MΩ 0.012+5
1000.00V 10mV 10MΩ 0.012+5
resistive
200.000Ω 1mΩ 1mA 0.05+8
2.00000kΩ 10mΩ 1mA 0.05+5
20.0000kΩ 100mΩ 100μA 0.05+5
200.000kΩ 10μA 0.05+5
2.000000kΩ 10Ω 1μA 0.05+5
10.0000MΩ 100Ω 0.5μA 0.30+5
1000.000MΩ 1kΩ 0.5μA /10MΩ 3.00+8
DC current
20.0000mA 100nA 0.05+15
200.000mA 1μA 0.05+5
1.00000A 10μA 0.1Ω 0.20+5
10.0000A 100μA 0.01Ω 0.20+5
Short Circuit Test
2000.00Ω 10mΩ 1mA 0.05+5
Diode Testing
6.0000V 100μV 1mA@6V 0.05+15
capacitors
10.00nF 0.01nF 10μA 2.0+10
100.0nF 0.1nF 10μA 2.0+4
1.000μF 0.001μF 100μA 2.0+4
10.00μF 0.01μF 1mA 2.0+4
100.0μF 0.1μF 1mA 2.0+4
Specification(*1)
Gear(*3) resolution (of a photo) frequency Accuracy 1 year (23℃±5℃)
True RMS AC (AC+DC/Ac coupled) voltage
200.0000 mV 1μV 20Hz - 45Hz 1.0 + 100
200.0000 mV 1μV 45Hz - 10kHz 0.3 + 100
200.0000 mV 1μV 10kHz - 30kHz 1.5 + 300
200.0000 mV 1μV 30kHz - 100kHz 5.0 + 300
2.00000 V 10μV 20Hz - 45Hz 1.0 + 100
2.00000 V 10μV 45Hz - 10kHz 0.3 + 100
2.00000 V 10μV 10kHz - 30kHz 1.5 + 100
2.00000 V 10μV 30kHz - 100kHz 3.0 + 200
20.0000V 100μV 20Hz - 45Hz 1.0 + 100
20.0000V 100μV 45Hz - 10kHz 0.2 + 100
20.0000V 100μV 10kHz - 30kHz 1.5 + 100
20.0000V 100μV 30kHz - 100kHz 3.0 + 200
200.000V 1mV 20Hz - 45Hz 1.0 + 100
200.000V 1mV 45Hz - 10kHz 0.2 + 100
200.000V 1mV 10kHz - 30kHz 1.5 + 100
200.000V 1mV 30kHz - 100kHz 3.0 + 200
750.00V 10mV 20Hz - 45Hz 1.0 + 100
750.00V 10mV 45Hz - 10kHz 0.2 + 100
750.00V 10mV 10kHz - 30kHz 1.5 + 100
750.00V 10mV 30kHz - 100kHz 3.0 + 200
True RMS AC (AC+DC/Ac coupling) current
20.0000 mA 100nA 20Hz - 45Hz 1.5 + 100
20.0000 mA 100nA 45Hz - 2kHz 0.5 + 100
200.000 mA 100nA 2kHz - 10kHz 2.0 + 200
200.000 mA 1μA 20Hz - 45Hz 1.5 + 100
200.000 mA 1μA 45Hz - 2kHz 0.5 + 100
20.0000 mA 1μA 2kHz - 10kHz 2.0 + 200
100000A 10μA 20Hz - 45Hz 1.5 + 100
100000A 10μA 45Hz - 2kHz 0.5 + 100
100000A 10μA 2kHz - 10kHz 2.0 + 200
10.0000A 100μA 20Hz - 45Hz 1.5 + 100
10.0000A 100μA 45Hz - 2kHz 1.0 + 100
10.0000A 100μA 2kHz - 10kHz -----
frequency
(Voltage) 10Hz-1MHz ----- ----- 0.01+3
(Current) 20Hz-10kHz ----- ----- 0.01+3
Temperature (thermocouple)
'-200℃~0℃ 0.6 J/T/K 0.6°C (MAX)
'0℃~+300℃ 0.3 J/T/K 0.3°C (MAX)
general
demonstrate VFD,Two Colors Display
connector RS-232.USB device (USBBCDC & USBTMC)
power supply  AC 100V / 120V / 220V / 240V ±10%.50~60Hz;Power Consumption Max.15VA
Size & Weight 265(W) x 107(H) x 302(D) mm,approx. 2.9kg

Standard Accessories

Safety Guide x 1
Power cord x 1
Test Lead GTL-207 x 1

CD-ROM x 1 (includes complete instruction manual e-file, drivers and software)

Optional Accessories

GTL-108A 4-wire test lead, approx. 1100mm

GTL-205A Temperature measuring wire adapter + thermocouple (K type), approx. 1000mm

GTL-232 RS-232C communication cable, null model 9-pin female-female cable, approx. 2000 mm

GTL-246 USB communication cable, A-B type, approx. 1200mm

GRA-422 Rack (19" 2U)

GDM-TL1 Test Lead Set (for all meter series)

GSC-014 Meter Accessory Kit

Ordering Information

GDM-8352 5 1/2 Digit Dual Measurement Digital Meter

Optional Accessories

GTL-108A 4-wire Resistance Measuring Wire (Kelvin Clip), Approx. 110cm

GTL-205 Temperature cable adapter and thermocouple cable (K-type), approx. 100cm

GTL-232 RS-232C cable, 9-pin to 9-pin female, null modem for computer, approx. 200cm

GTL-246 USB cable, A-B format, approx. 120cm

GRA-422 Rack Panel (19" 2U)

Expand More
GDM-8352 Digital MultimeterGDM-8352 Digital Multimeter

Click to enquire

Product consultation and purchase:18218718851

I already understand