Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit
Fluke 2062 Advanced Line Finder Kit

Fluke 2062 Advanced Line Finder Kit

Main characteristics

  • Quickly and accurately locate energized and de-energized wires in walls, ceilings and floors
  • Smart Sensor™ locates energized wires and displays them on the color display
  • Find breaks or open and short circuits and easily identify circuit breakers and fuses
  • Safety class CAT IV 600 V
  • Includes i400 AC signal clamp for sensing detection signals on cables when bare wires are inaccessible

SKU:Fluke 2062 Category. Brand.

Inquire about this product

Product Overview: Fluke 2062 Advanced Line Finder Kit

Built to keep you safe

The Fluke 2062 Advanced Wire Finder Kit provides accurate and safe troubleshooting of energized and de-energized wires in residential, commercial and industrial environments up to a CAT IV 600 V rating. This CAT rating is as high a level of protection as a wire finder can provide. This rating protects you from dangerous transient overvoltage levels (up to 8,000 V peak) that can occur in industrial and utility grid environments. This is particularly important in environments such as industrial plants, factories and hospitals where critical equipment cannot be taken offline.

Intelligent detection saves time

The Smart Sensor™, unique to the Fluke 2062, makes wire detection faster and easier. It locates energized wires in walls, floors, and ceilings and displays them on the 3.5-inch high-resolution TFT LCD display. Whether you're a novice or an expert, help screens embedded in the display help make it easy to use. The tip sensor beeps when locating wires, and the smart sensor visualizes and pinpoints the path of energized wires, eliminating guesswork.

Wire detection tailored to your application

Whether it's electrical wiring and equipment troubleshooting for residential and commercial buildings or high-voltage public grid equipment, the Fluke 2062 can find breaks or open and short circuits. It has different modes and functions that provide the flexibility to troubleshoot a wide range of wiring and circuit problems that may be encountered on the job.

Four receiver detection modes

The 2062-R receiver uses two methods to detect signals in wires and cables: passive detection without a transmitter in non-contact voltage detection mode, and active detection with a transmitter in all other modes. The receiver's tip sensor detects wires in corners, tight spaces, and junction boxes.

  • "Smart Scan" for detecting energized wires and displaying them on the large color LCD display
  • "Tip Sensor" mode for detecting wires with higher accuracy
  • "Circuit breaker locator" mode for easy identification of circuit breakers and fuses based on the highest signal detected and recorded by the transmitter
  • "NCV Non-Contact Voltage Detection" mode to detect energized wires without using a transmitter

Three transmitter power modes

The 2000-T Transmitter operates on energized and de-energized circuits at up to CAT IV 600 V ratings and has high, low and loop modes. These modes vary the strength of the sensed signal and help provide more accurate results depending on the circuit you are probing.

  • "High Signal" mode for normal energized and de-energized circuits
  • "Low-signal" mode for precise detection by low signal to minimize coupling to nearby wires and metal objects
  • "Loop" mode for closed-loop de-energized circuits

Two transmitter output frequencies

The 2000-T automatically senses if the system is powered on or off and automatically selects an output frequency of 6 kHz or 33 kHz.

Eight receiver sensitivity levels

Higher sensitivity levels mean more flexibility and accuracy when detecting.

Complete Kit

The Fluke 2062 Advanced Wire Finder Kit comes conveniently equipped with all the accessories needed to probe wires and circuits. The accessory kit includes test leads, test probes, flat and round socket adapters, and alligator clips to connect the transmitter to the electrical system. Connecting the transmitter to bare wire with the included alligator clips and test leads will always give the most accurate results. However, where direct connection to bare wire is not possible, a raised 6 kHz signal can be sensed through the insulation in "loop" mode with the supplied i400 signal clamp. The kit also includes a magnetic lanyard, battery and hard carrying case.

Product Specification: Fluke 2062 Advanced Line Finder Kit

routine 2062R Receiver 2000T launcher i400 AC Signal Clamp
Measurement category CAT IV 600 V CAT IV 600 V CAT IV 600 V, CAT III 1000 V
operating voltage 600 V AC/DC 600 V AC/DC 1000 V AC
operating frequency Energized: 6.25 kHz
Power failure: 32.768 kHz
Power on/loop: 6.25 kHz
Power failure: 32.768 kHz
-
signal indication Numeric and bar graph displays and beeps LED indicators and beeps -
response time Smart sensor: 500 ms
Tip sensor (power on/off): 500 ms
NCV: 500 ms
Battery monitoring: 5 s
Line voltage monitoring: 1 s
Battery voltage monitoring; 5 s
-
Signal current output (typical) - Energized circuits:
High power mode: 60 mA rms
Low power mode: 30 mA rms
Disconnect circuit:
High power mode: 110 mA rms
Low power mode: 40 mA rms
Loop mode, using test leads: 160 mA rms
Loop mode, using i400 AC current clamp:
385 mA RMS
-
Signal voltage output (nominal) - Energized circuits:
High power mode: 14 W @ 230 V ac/50 Hz.
3.33 kΩ @ 230 V ac
Low power mode: 4.6 W @ 230 V ac/50 Hz.
11.5 kΩ @ 230 V ac
Disconnect circuit:
High Power Mode: 31 V RMS, 140 Vp-p.
0.86 W @ 1 kΩ Load
Low Power Mode: 27.5 V RMS, 120 Vp-p.
0.1 W @ 1 kΩ Load
Loop mode, using test leads: 32 V rms.
140 Vp-p, 0.87 W @ 1 kΩ Load
Loop mode, using i400 AC current clamp:
31 mV, 0.89 W @ 1 Ω Load
-
Scope testing (open air) Smart Sensor Detection Indication Mode
≤15 cm (6 in), 230 V AC.
High mode: Sensitivity level 2
Tip sensor: energized
Maximum distance through air: 6.1 m (20 ft) max.
Accurate positioning: approx. 5 cm (1.97 in)
Tip sensor: power off
Maximum distance through air: 4.5 m (14.7 ft) max.
Accurate positioning: approx. 5 cm (1.97 in)
NCV (40 Hz to 400 Hz)
Maximum sensitivity: 90 V, 2 m max.
Minimum sensitivity: 600 V, maximum 1 cm
-
Current range - - 400 A
Fundamental Accuracy - - 2 % + 0.06 A
(45 Hz to 400 Hz)
monitor
Display Size 89 mm (3.5 in) LCD LED indicator -
Display size (W × H) 70 mm × 52 mm (2.76 in × 2.07 in) - -
Display resolution 480 pixels × 320 pixels - -
Display Type Color TFT LCD LED indicator -
Display Color 16-bit Operation Mode LED Indicator: Red
Battery status LEDs: green, yellow, red
-
backlight be - -
matrix
operating temperature -20 °C to 50 °C (-4 °F to 122 °F) -20 °C to 50 °C (-4 °F to 122 °F) -20 °C to 50 °C (-4 °F to 122 °F)
Operating humidity 45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
10 °C to <30 °C
(95 %: 50 °F to <86 °F)
30 °C to <40 °C
(75 %: 86 °F to <104 °F)
40 °C to <50 °C
(45%: 104 °F to <122 °F)
Working altitude 2000 m (6561 ft) 2000 m (6561 ft) 2000 m (6561 ft)
transient protection - 8.00 kV (1.2/50μS surge) -
contamination level 2 2 2
IP rating IP 40 IP 40 IP 40
Drop test 1 m (3.28 ft) 1 m (3.28 ft) 1 m (3.28 ft)
mechanical mean
power supply 4 × AA (alkaline) 8 × AA (alkaline) -
Power consumption (typical) 110 mA High power/low power mode: 70 mA
Loop mode, using current clamp: 90 mA
No signal consumption
Transmission: 10 mA
-
Battery Life Approximately 20 hours High power/low power mode: approx. 25 hours
Loop mode: approximately 18 hours
-
Low battery indicator be be -
(electrical) fuse - 1.6 A, 700 V, fast blow type.
Ø 6 x 32 mm, 50 kA interruption
-
Maximum measurable wire size - - 32 mm (1.26 in)
Dimensions (L x W x H) Approx. 277 x 112 x 65 mm
(10.92 x 4.43 x 2.55 in)
Approx. 183 x 93 x 50 mm
(7.2 x 3.66 x 1.97 in)
Approx. 150 x 70 x 30 mm
(5.9 x 2.75 x 1.18 in)
weights Approx. 0.544 kg (1.20 lb) Approx. 0.57 kg (1.25 lb) Approx. 0.114 kg (0.25 lb)
mechanical mean 2000ACC Test Lead Accessory Kit
including through 2 x 1 m test leads (red, black),
1 x 7 m test lead (green),
2 test probes (black)
2 Alligator clips (red, black),
2 Chip Socket Adapters (Red, Black)
2 Round Socket Adapters (Red, Black)
Measurement category CAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips),
CAT II 300 V (socket adapter)
Operating voltage and current 600 V max. 10 A (red/black lead), 600 V max. 10 A (green lead), 1000 V max. 8 A (black probe)
max. 600 V 10 A (alligator clips), max. 300 V 10 A (socket adapter)
operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Operating humidity 10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F),
40 ºC to <50 ºC (45%: 104 ºF to <122 ºF)
Storage temperature and humidity 0 °C to 60 °C (32 °F to 140 °F), <95% (non-condensing)
Working altitude 2000 m (6561 ft)
contamination level 2
Waterproof and dustproof IP 20
drop resistance 1 m (3.28 ft)
Overall dimensions Red/black wire: 1 m (3.28 ft), green wire: 7 m (22.97 ft), alligator clips: approx. 95 × 45 × 24 mm (3.74 × 1.77 × 0.94 in),
Socket adapter: 72 × 18 × 18 mm (2.83 × 0.71 × 0.71 in)
weights Approx. 0.4 kg (0.88 lb)

Model: Fluke 2062 Advanced Line Finder Kit

2062

Kit Includes:

  • Fluke 2062R Advanced Line Finder Receiver with Smart Sensor™ Smart Sensor
  • Fluke 2000T Advanced Line Finder Transmitter
  • i400 AC Signal Clamp
  • Fluke 2000ACC Test Lead Accessory Kit for 2052/2062
  • Magnetic hooks for smart lanyards
  • Premium Hard Carrying Case
  • batteries
  • Quick Reference Guide

Fluke 2062 Advanced Line Finder Kit | Datasheet [login to download and view]

2052R/2062R/2000T Wire Tracer Receiver User Manual | User Manual [Please login to download and view].

Expand More
Fluke 2062 Advanced Line Finder KitFluke 2062 Advanced Line Finder Kit

Click to enquire

Product consultation and purchase:18218718851

I already understand